We demonstrate a dual-band continuum light source centered at 830 and 1300 nm. for optical coherence tomography (OCT) generated by pumping a photonic crystal fiber having two closely spaced zero-dispersion wavelengths with a femtosecond laser at 1059 nm. By use of polarization control, sidelobe suppression can be improved up to approximately 7.7 dB. By employing compression of the pump pulses, the generated spectrum is smooth and near-Gaussian, resulting in a point-spread function with negligible sidelobes. We demonstrate ultrahigh-resolution OCT imaging of biological tissue in vivo and in vitro using this light source and compare it with conventional-resolution OCT imaging at 1300 nm. (c) 2007 Optical Society of America.
引用
收藏
页码:1787 / 1794
页数:8
相关论文
共 50 条
  • [1] Ultrahigh-resolution optical coherence tomography
    Drexler, W
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 47 - 74
  • [2] In vivo ultrahigh-resolution optical coherence tomography
    Drexler, W
    Morgner, U
    Kärtner, FX
    Pitris, C
    Boppart, SA
    Li, XD
    Ippen, EP
    Fujimoto, JG
    OPTICS LETTERS, 1999, 24 (17) : 1221 - 1223
  • [3] Ultrahigh-resolution optical coherence tomography in glaucoma
    Wollstein, G
    Paunescu, LA
    Ko, TH
    Fujimoto, JG
    Kowalevicz, A
    Hartl, I
    Beaton, S
    Ishikawa, H
    Mattox, C
    Singh, O
    Duker, J
    Drexler, W
    Schuman, JS
    OPHTHALMOLOGY, 2005, 112 (02) : 229 - 237
  • [4] Ultrahigh-resolution ophthalmic optical coherence tomography
    Drexler, W
    Morgner, U
    Ghanta, RK
    Kärtner, FX
    Schuman, JS
    Fujimoto, JG
    NATURE MEDICINE, 2001, 7 (04) : 502 - 507
  • [5] Ultrahigh-resolution ophthalmic optical coherence tomography
    Wolfgang Drexler
    Uwe Morgner
    Ravi K. Ghanta
    Franz X. Kärtner
    Joel S. Schuman
    James G. Fujimoto
    Nature Medicine, 2001, 7 : 502 - 507
  • [6] Ultrahigh-Resolution Optical Coherence Tomography with LED-Phosphor-Based Broadband Light Source
    Tsai, Meng-Tsan
    Hung, Jeng-Jie
    Chan, Ming-Che
    APPLIED PHYSICS EXPRESS, 2013, 6 (12)
  • [7] Ultrahigh-resolution optical coherence tomography with a fiber laser source at 1 μm
    Lim, H
    Jiang, Y
    Wang, YM
    Huang, YC
    Chen, ZP
    Wise, FW
    OPTICS LETTERS, 2005, 30 (10) : 1171 - 1173
  • [9] In vivo ultrahigh-resolution, functional optical coherence tomography
    Drexler, W.
    Morgner, U.
    Kaertner, F.
    Ghanta, R.K.
    Pitris, C.
    Li, X.
    Ippen, E.P.
    Fujimoto, J.G.
    Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest, 2000, : 416 - 418
  • [10] Optimal wavelength for ultrahigh-resolution optical coherence tomography
    Wang, YM
    Nelson, JS
    Chen, ZP
    Reiser, BJ
    Chuck, RS
    Windeler, RS
    OPTICS EXPRESS, 2003, 11 (12): : 1411 - 1417