Optimization of operating temperatures in the gas operated single to triple effect vapour absorption refrigeration cycles

被引:28
|
作者
Azhar, Md [1 ]
Siddiqui, M. Altamush [1 ]
机构
[1] Aligarh Muslim Univ, Dept Mech Engn, Computat & Expt Heat Transfer Res Lab, ZH Coll Engn & Technol, Aligarh 202002, Uttar Pradesh, India
关键词
Triple Effect; Gas energy sources; LiBr-H2O; Coefficient of performance; Optimum generator temperature; Optimum condenser temperature; Salt concentration; GENERATOR TEMPERATURES; THERMODYNAMIC ANALYSIS; LITHIUM-BROMIDE; COOLING SYSTEM; EXERGY ANALYSIS; WATER; PERFORMANCE; ENERGY; COMPRESSION; CHILLER;
D O I
10.1016/j.ijrefrig.2017.06.033
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermodynamic analysis of LiBr-H2O single, double and triple effect vapour absorption cycles has been carried out using LPG and CNG as sources of energy. Optimization of operating temperatures in single to triple effect cycles has been carried out for maximum COP of the system and minimum gas requirement in it at desired temperatures in evaporator, absorber and main condenser using iterative technique. In single effect cycle, optimum temperatures in main generator have been obtained, while in double effect cycle, low pressure generator, high pressure condenser and main generator temperatures have been optimized. In triple effect cycle having three condensers and three generators, condenser temperatures (T-c3 and T-c4) and generator temperatures (T-g2, T-g3 and T-g) have been optimized. The maximum COP of triple effect cycle goes up to 1.955 which is around 132% higher than single effect cycle with its gas requirement reduced to around 122% at the same conditions. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:401 / 425
页数:25
相关论文
共 50 条
  • [31] Performance Analysis and Optimization of Vapour Absorption Refrigeration System Using Different Working Fluid Pairs
    Kalura, Paras
    Kashyap, Susheem
    Sharma, Vishal
    Raghav, Geetanjali
    Kalra, Jasmeet
    [J]. HARMONY SEARCH AND NATURE INSPIRED OPTIMIZATION ALGORITHMS, 2019, 741 : 527 - 537
  • [32] Facts about triple-effect absorption chiller cycles
    DeVault, R.C.
    Grossman, G.
    [J]. Gas industries, 1993, 37 (11): : 26 - 28
  • [33] Thermoeconomic evaluation and optimization of a double-effect H2O/LiBr vapour-absorption refrigeration system
    Misra, RD
    Sahoo, PK
    Gupta, A
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2005, 28 (03) : 331 - 343
  • [34] EXPERIMENTAL ANALYSES OF TRIPLE FLUID VAPOUR ABSORPTION REFRIGERATION SYSTEM DRIVEN BY ELECTRICAL ENERGY AND ENGINE WASTE HEAT
    Balasubramanian, Andi
    Jayaraman, Venkatesan
    Sivan, Suresh
    Vairavan, Mariappan
    [J]. THERMAL SCIENCE, 2019, 23 (05): : 2995 - 3001
  • [35] Effect of water vapour absorption on hydroxyl temperatures measured from Svalbard
    Chadney, Joshua M.
    Whiter, Daniel K.
    Lanchester, Betty S.
    [J]. ANNALES GEOPHYSICAE, 2017, 35 (03) : 481 - 491
  • [36] Conceptual process design and optimization of refrigeration cycles for the liquefaction of boil-off gas
    Son H.
    Cho H.
    Gim M.
    Yoon S.
    Jang M.-G.
    Kwak D.-H.
    Kim J.-K.
    [J]. Chemical Engineering Transactions, 2018, 70 : 169 - 174
  • [37] Energy and exergy analysis of LiBr-H2O-operated vapour absorption refrigeration system using the ANN approach
    Singh, Dheerendra Vikram
    Verma, Tikendra Nath
    [J]. International Journal of Ambient Energy, 2022, 43 (01) : 905 - 917
  • [38] A novel approach for operational optimization of multi-stage refrigeration cycles in gas refineries
    Kalantar-Neyestanaki, Hossein
    Mafi, Mostafa
    Ashrafizadeh, Ali
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 80 : 169 - 181
  • [39] Two-Objective Optimization of a Cogeneration System Based on a Gas Turbine Integrated with Solar-Assisted Rankine and Absorption Refrigeration Cycles
    Javaherian, Amirreza
    Ghasemi, Sadaf
    Seyed Mahmoudi, Seyed Mohammad
    Rosen, Marc A.
    Sadeghi, Mohsen
    [J]. SUSTAINABILITY, 2023, 15 (21)
  • [40] EXERGY ANALYSIS OF AN SINGLE-EFFECT ABSORPTION REFRIGERATION SYSTEM OPERATING WITH THE LiBr/H2O PAIR
    Gomes Almeida, Igor Marcel
    Formiga Barbosa, Cleiton Rubens
    Oliveira Fontes, Francisco de Assis
    [J]. HOLOS, 2010, 26 (03) : 69 - 81