Percutaneous Radiofrequency Ablation for Hepatic Tumors Abutting the Diaphragm: Clinical Assessment of the Heat-Sink Effect of Artificial Ascites

被引:34
|
作者
Nam, Sang Yu
Rhim, Hyunchul [1 ]
Kang, Tae Wook
Lee, Min Woo
Kim, Young-Sun
Choi, Dongil
Lee, Won Jae
Park, Yulri
Chang, Ilsoo
Lim, Hyo K.
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Radiol, Seoul 135710, South Korea
关键词
artificial ascites; hepatocellular carcinoma; radiofrequency ablation; STAGE HEPATOCELLULAR-CARCINOMA; LIVER-TUMORS; BLOOD-FLOW; PHARMACOLOGICAL MODULATION; COAGULATION DIAMETER; TISSUE ABLATION; THERMAL-INJURY; RABBIT MODEL; IN-VIVO; COMPLICATIONS;
D O I
10.2214/AJR.09.2979
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This study was designed to assess whether artificial ascites has a heat-sink effect on the ablation zone for percutaneous radiofrequency ablation (RFA) of hepatic tumors abutting the diaphragm. MATERIALS AND METHODS. We retrospectively assessed 28 patients who underwent percutaneous RFA for the treatment of a single nodular hepatic tumor that abutted the diaphragm from July 2000 to December 2006. All patients underwent ultrasound-guided RFA using internally cooled electrodes. A single ablation for 12 minutes was applied using 3-cm active-tip electrodes. We divided patients into two groups on the basis of whether artificial ascites was introduced before RFA: Group A consisted of patients who received artificial ascites with a mean of 760 mL of a 5% dextrose in water solution (n = 15) and group B consisted of patients who did not receive artificial ascites (n = 13). The volume of the ablation zone was measured on CT images obtained immediately after the ablation procedure, and imaging findings were compared for both groups using the Student's t test. We also compared the local tumor progression rate between both groups using the chi-square test (mean follow-up, 37.4 months). RESULTS. There was no significant difference between the two patient groups with regard to age, sex, Child-Pugh class, or tumor location (p > 0.05). The tumors were significantly smaller in group A patients (mean +/- SD, 1.6 +/- 0.5 cm) than in group B patients (2.1 +/- 0.7 cm) (p = 0.019). The mean volume of the RFA zone was 31.6 +/- 11.9 cm(3) in group A patients and 30.9 +/- 11.0 cm(3) in group B patients. There was no significant difference between the groups in the ablation volume (p = 0.871). Local tumor progression was noted in four patients (26.7%) in group A and in three patients (23.1%) in group B. There was no significant difference in the local tumor progression rate between the two groups (p = 0.83). CONCLUSION. Artificial ascites did not show a heat-sink effect on the volume of the ablation zone after percutaneous RFA for the treatment of a hepatic tumor abutting the diaphragm.
引用
收藏
页码:W227 / W231
页数:5
相关论文
共 33 条
  • [31] Clinical Application of Artificial Ascites in assisting CT-guided Percutaneous Cryoablation of Hepatic Tumors Adjacent to the Gastrointestinal Tract
    Li, Bing
    Liu, Chuan
    Xu, Xiao-Xue
    Li, Yang
    Du, Yong
    Zhang, Chuan
    Zheng, Hou-Jun
    Yang, Han-Feng
    SCIENTIFIC REPORTS, 2017, 7
  • [32] Thermal effect of percutaneous radiofrequency ablation with a clustered electrode for vertebral tumors: In vitro and vivo experiments and clinical application
    Zhao Wei
    Peng Zhao-Hong
    Chen Jin-Zhou
    Hu Ji-Hong
    Huang Jian-Qiang
    Jiang Yong-Neng
    Luo Gang
    Yi Gen-Fa
    Wang Hui
    Jin Shen
    Gao Bu-Lang
    JOURNAL OF BONE ONCOLOGY, 2018, 12 : 69 - 77
  • [33] Image-Guided Percutaneous Radiofrequency Ablation of Central Renal Cell Carcinoma: Assessment of Clinical Efficacy and Safety in 31 Tumors
    Dai, Ying
    Covarrubias, Diego
    Uppot, Raul
    Arellano, Ronald S.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (12) : 1643 - 1650