High-power short duration vs. conventional radiofrequency ablation of atrial fibrillation: a systematic review and meta-analysis

被引:73
|
作者
Ravi, Venkatesh [1 ]
Poudyal, Abhushan [2 ]
Abid, Qurrat-Ul-Ain [1 ]
Larsen, Timothy [1 ]
Krishnan, Kousik [1 ]
Sharma, Parikshit S. [1 ]
Trohman, Richard G. [1 ]
Huang, Henry D. [1 ]
机构
[1] Rush Univ, Dept Med, Div Cardiol, Sect Electrophysiol,Med Ctr, 1717 W Congress Pkwy Suite 317 Kellogg, Chicago, IL 60612 USA
[2] John H Stroger Hosp Cook Cty, Dept Med, Div Cardiol, Chicago, IL USA
来源
EUROPACE | 2021年 / 23卷 / 05期
关键词
Atrial fibrillation; Radiofrequency ablation; High-power short duration; Freedom from atrial arrhythmia;
D O I
10.1093/europace/euaa327
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We sought to compare the effectiveness and safety of high-power short-duration (HPSD) radiofrequency ablation (RFA) with conventional RFA in patients with atrial fibrillation (AF). Methods and results MEDLINE, Cochrane, and ClinicalTrials.gov databases were searched until 15 May 2020 for relevant studies comparing HPSD vs. conventional RFA in patients undergoing initial catheter ablation for AF. A total of 15 studies involving 3718 adult patients were included in our meta-analysis (2357 in HPSD RFA and 1361 in conventional RFA). Freedom from atrial arrhythmia was higher in HPSD RFA when compared with conventional RFA [odds ratio (OR) 1.44, 95% confidence interval (CI) 1.10-1.90; P = 0.009]. Acute PV reconnection was lower (OR 0.56, P = 0.005) and first-pass isolation was higher (OR 3.58, P < 0.001) with HPSD RFA. There was no difference in total complications between the two groups (P = 0.19). Total procedure duration [mean difference (MD) -37.35 min, P < 0.001], fluoroscopy duration (MD -5.23 min, P = 0.001), and RF ablation time (MD -16.26 min, P < 0.001) were all significantly lower in HPSD RFA. High-power short-duration RFA also demonstrated higher freedom from atrial arrhythmia in the subgroup analysis of patients with paroxysmal AF (OR 1.80, 95% CI 1.29-2.50; P < 0.001), studies with >= 50 W protocol in the HPSD RFA group (OR 1.53, 95% CI 1.08-2.18; P = 0.02] and studies with contact force sensing catheter use (OR 1.65, 95% CI 1.21-2.25; P = 0.002). Conclusion High-power short-duration RFA was associated with better procedural effectiveness when compared with conventional RFA with comparable safety and shorter procedural duration.
引用
收藏
页码:710 / 721
页数:12
相关论文
共 50 条
  • [21] Safety and efficacy of high power shorter duration ablation for atrial fibrillation: A systematic review and meta-analysis
    Li, Miao-Fu
    Wu, Jing
    Jin, Chao-Lun
    Chen, Chao-Feng
    Xu, Yi-Zhou
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2021, 75 (04)
  • [22] High-power short-duration ablation of atrial fibrillation: A contemporary review
    Naniwadekar, Aditi
    Dukkipati, Srinivas R.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (03): : 528 - 540
  • [23] Meta-Analysis of Pulsed-Field Ablation Versus- High-Power Short-Duration Ablation for Atrial Fibrillation
    Xue, Jun
    Huang, Qunying
    Yu, Fuling
    Mao, Yinjun
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2025,
  • [24] Efficacy and Safety of High-Power Short-Duration Radiofrequency Catheter Ablation of Atrial Fibrillation
    Park, Je-Wook
    Yang, Song-Yi
    Kim, Min
    Yu, Hee Tae
    Kim, Tae-Hoon
    Uhm, Jae-Sun
    Joung, Boyoung
    Lee, Moon-Hyoung
    Pak, Hui-Nam
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [25] Meta-analysis of high power short duration in atrial fibrillation ablation - a superior efficient ablation strategy
    Xu, Min
    Yang, Yan
    Zhang, Dayong
    Jiang, Weifeng
    ACTA CARDIOLOGICA, 2022, 77 (01) : 14 - 32
  • [26] COMPARATIVE EFFICACY AND SAFETY OF PULSE FIELD ABLATION VS. CRYOABLATION AND RADIOFREQUENCY ABLATION IN THE TREATMENT OF ATRIAL FIBRILLATION: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Akbar, Usman
    Umer, Ahmed Muaaz
    Golla, Maheswara Satya
    Farooqui, Sabeeh
    Muhibullah, Fnu
    Vorla, Mounica
    Anwar, Rana Usman
    Que, Nouman Shafi
    Rizwan, Umer
    Khan, Muhammad Aslam
    Basit, Jawad
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 196 - 196
  • [27] Comparative analysis of recurrence predictors and outcomes for atrial tachyarrhythmia following atrial fibrillation ablation: high-power short-duration vs. conventional pulmonary vein isolation
    Yazaki, Kyoichiro
    Ejima, Koichiro
    Kataoka, Shohei
    Higuchi, Satoshi
    Kanai, Miwa
    Yagishita, Daigo
    Shoda, Morio
    Yamaguchi, Junichi
    HEART AND VESSELS, 2025, 40 (02) : 149 - 160
  • [28] Radiofrequency ablation vs. antiarrhythmic drug therapy as first line treatment of symptomatic atrial fibrillation: systematic review and meta-analysis
    Hakalahti, Antti
    Biancari, Fausto
    Nielsen, Jens Cosedis
    Raatikainen, M. J. Pekka
    EUROPACE, 2015, 17 (03): : 370 - 378
  • [29] Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation
    Sun, Xuerong
    Lu, Jiang
    Lin, Jinxuan
    Feng, Tianjie
    Suo, Ni
    Zheng, Lihui
    Liu, Zhimin
    Chen, Gang
    Fan, Xiaohan
    Zhang, Shu
    Niu, Guodong
    CARDIOLOGY RESEARCH AND PRACTICE, 2021, 2021
  • [30] Pulmonary vein isolation for atrial fibrillation using true high-power short-duration vs. cryoballoon ablation
    Jonas Wörmann
    Jakob Lüker
    Jan-Hendrik van den Bruck
    Karlo Filipovic
    Susanne Erlhöfer
    Cornelia Scheurlen
    Sebastian Dittrich
    Jan-Hendrik Schipper
    Daniel Steven
    Arian Sultan