Radiochromic film dosimetry of a low energy proton beam

被引:45
|
作者
Piermattei, A [1 ]
Miceli, R
Azario, L
Fidanzio, A
delle Canne, S
De Angelis, C
Onori, S
Pacilio, M
Petetti, E
Raffaele, L
Sabini, MG
机构
[1] Univ Cattolica Sacro Cuore, Ist Fis, Rome, Italy
[2] Ist Super Sanita, I-00161 Rome, Italy
[3] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95129 Catania, Italy
关键词
proton dosimetry; radiochromic film dosimetry;
D O I
10.1118/1.599032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work some dosimetric characteristics of MD-55-2 GafChromic films were studied in a low energy proton beam (21.5 MeV) directly in a water phantom. The nonlinearity of the optical density was quantified by a factor P-lin. A correction factor P-en, that accounts for optical density dependence on the energy, was empirically determined. The effects of detector thickness in depth dose measurements and of the film orientation with respect to beam direction were investigated. The results show that the MD-55-2 films provide dose measurements with the films positioned perpendicularly to the proton beam. A dosimetric formalizm is proposed to determine the dose to water at depth d, with films oriented perpendicularly to the beam axis. This formalism uses a calibration factor of the radiochromic film determined directly on the proton beam at a reference depth in water, and the P-lin factor, that takes into account the nonlinearity of the calibration curve and the P-en factor that, in turn takes into account the change of proton beam energy in water. The MD-55-2 films with their high spatial resolution and the quasiwater equivalent material are attractive, positioned perpendicularly along the beam axis, for the absolute dose determination of very small beam sizes and modulated proton beams. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01107-X].
引用
收藏
页码:1655 / 1660
页数:6
相关论文
共 50 条
  • [21] Accuracy And Reproducibility Of Radiochromic Film Dosimetry
    Laosa, C.
    Calvo-Ortega, J. F.
    Moragues, S.
    Casals, J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S916 - S916
  • [22] Directional dependence in film dosimetry: radiographic and radiochromic film
    Suchowerska, N
    Hoban, P
    Butson, M
    Davison, A
    Metcalfe, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05): : 1391 - 1397
  • [23] Use of a control film piece in radiochromic film dosimetry
    Aldelaijan, Saad
    Alzorkany, Faisal
    Moftah, Belal
    Buzurovic, Ivan
    Seuntjens, Jan
    Tomic, Nada
    Devic, Slobodan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 202 - 207
  • [24] A prototype quantitative film scanner for radiochromic film dosimetry
    Ranade, Manisha K.
    Li, Jonathan G.
    Dubose, Ryan S.
    Kozelka, Jakub
    Simon, William E.
    Dempsey, James F.
    MEDICAL PHYSICS, 2008, 35 (02) : 473 - 479
  • [25] Estimating the Accuracy of Proton Beam Dosimetry with Film Detectors
    Merzlikin, G. V.
    Kokontsev, D. A.
    Yakovlev, I. A.
    Akulinichev, S. V.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2024, 67 (05) : 1001 - 1006
  • [26] Proton Beam Dosimetry Using Gafchromic EBT Film
    Zhao, Li
    Das, I.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [27] A protocol for accurate radiochromic film dosimetry using Radiochromic.com
    Mendez, Ignasi
    Jose Rovira-Escutia, Juan
    Casar, Bozidar
    RADIOLOGY AND ONCOLOGY, 2021, 55 (03) : 369 - 378
  • [28] The performance of an optical cone-beam CT scanner adapted for radiochromic film dosimetry
    Babic, Steven
    Jordan, Kevin
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21): : N377 - N389
  • [29] A review on radiochromic film dosimetry for dose verification in high energy photon beams
    Santos, Tania
    Ventura, Tiago
    Lopes, Maria do Carmo
    RADIATION PHYSICS AND CHEMISTRY, 2021, 179
  • [30] Photon beam dosimetry in the superficial buildup region using radiochromic EBT film stack
    Chiu-Tsao, Sou-Tung
    Chan, Maria F.
    MEDICAL PHYSICS, 2009, 36 (06) : 2074 - 2083