Radiochromic film dosimetry of a low energy proton beam

被引:45
|
作者
Piermattei, A [1 ]
Miceli, R
Azario, L
Fidanzio, A
delle Canne, S
De Angelis, C
Onori, S
Pacilio, M
Petetti, E
Raffaele, L
Sabini, MG
机构
[1] Univ Cattolica Sacro Cuore, Ist Fis, Rome, Italy
[2] Ist Super Sanita, I-00161 Rome, Italy
[3] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95129 Catania, Italy
关键词
proton dosimetry; radiochromic film dosimetry;
D O I
10.1118/1.599032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work some dosimetric characteristics of MD-55-2 GafChromic films were studied in a low energy proton beam (21.5 MeV) directly in a water phantom. The nonlinearity of the optical density was quantified by a factor P-lin. A correction factor P-en, that accounts for optical density dependence on the energy, was empirically determined. The effects of detector thickness in depth dose measurements and of the film orientation with respect to beam direction were investigated. The results show that the MD-55-2 films provide dose measurements with the films positioned perpendicularly to the proton beam. A dosimetric formalizm is proposed to determine the dose to water at depth d, with films oriented perpendicularly to the beam axis. This formalism uses a calibration factor of the radiochromic film determined directly on the proton beam at a reference depth in water, and the P-lin factor, that takes into account the nonlinearity of the calibration curve and the P-en factor that, in turn takes into account the change of proton beam energy in water. The MD-55-2 films with their high spatial resolution and the quasiwater equivalent material are attractive, positioned perpendicularly along the beam axis, for the absolute dose determination of very small beam sizes and modulated proton beams. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01107-X].
引用
收藏
页码:1655 / 1660
页数:6
相关论文
共 50 条
  • [1] Radiochromic film dosimetry for a 62 MeV clinical proton beam
    Fidanzio, A
    Azario, L
    De Angelis, C
    Pacilio, M
    Onori, S
    Piermattei, A
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2002, 18 (01): : 15 - 23
  • [2] Radiochromic Film Quenching Effect Reduction for Proton Beam Dosimetry
    Aldelaijan, S.
    Alzorkany, F.
    Moftah, B.
    Alrumayan, F.
    Seuntjens, J.
    Lewis, D.
    Devic, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3489 - 3489
  • [3] Radiochromic film dosimetry for clinical proton beams
    Vatnitsky, SM
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (05) : 643 - 651
  • [4] Radiochromic film dosimetry for verification of dose distributions delivered with proton-beam radiosurgery
    Vatnitsky, SM
    Schulte, RWM
    Galindo, R
    Meinass, HJ
    Miller, DW
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (10): : 1887 - 1898
  • [5] Radiochromic Film Models for Proton Beam Therapy
    Rahimi, R.
    Chen, K. L.
    Fan, J.
    Khan, R.
    MEDICAL PHYSICS, 2024, 51 (10) : 7932 - 7933
  • [6] Radiochromic film dosimetry
    Soares, Christopher G.
    RADIATION MEASUREMENTS, 2006, 41 : S100 - S116
  • [7] Radiochromic EBT2 film dosimetry for low-energy protontherapy
    Angellier, G.
    Gautier, M.
    Herault, J.
    MEDICAL PHYSICS, 2011, 38 (11) : 6171 - 6177
  • [8] Radiochromic film containing spiropyran dye for dosimetry of low energy X-rays
    Kinashi, Kenji
    Miyashita, Yusuke
    Ishida, Kenji
    Ueda, Yasukiyo
    JOURNAL OF PHYSICAL ORGANIC CHEMISTRY, 2012, 25 (05) : 427 - 430
  • [9] Radiochromic Film Dosimetry Update
    Niroomand-Rad, A.
    Chiu-Tsao, S.
    Trichter, S.
    Das, I.
    MEDICAL PHYSICS, 2015, 42 (06) : 3626 - 3626
  • [10] Eigencolor radiochromic film dosimetry
    Bouchard, Hugo
    Billas, Ilias
    Subiel, Anna
    Duane, Simon
    MEDICAL PHYSICS, 2021, 48 (05) : 2592 - 2603