Press-fit metal-backed alumina sockets -: A minimum 5-year followup study

被引:0
|
作者
Bizot, P [1 ]
Larrouy, M [1 ]
Witvoet, J [1 ]
Sedel, L [1 ]
Nizard, R [1 ]
机构
[1] Hop Lariboisiere, Dept Traumatol & Orthopaed Surg, F-75475 Paris 10, France
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Two hundred thirty-four consecutive alumina-on-alumina hip replacements using a press-fit metal-backed socket, performed on 214 patients (98 women, 116 men) have been reviewed. These included 201 primary procedures and 33 revision procedures. The median age of the patients at the time of surgery was 62 Sears (range, 21-83 years). Fourteen patients (16 hips) died from unrelated causes. Eleven patients (11 hips) underwent a total hip arthroplasty revision for recurrent dislocation (one hip), deep infection (two hips), fracture of alumina femoral head (one hip), persistent hip pain (one hip) and aseptic loosening (six hips). The survival rate after 9 years was 93.4% when revision of the prosthesis was considered the end point, and 97.4% if revision of the prosthesis for aseptic loosening was considered the end point. Results were assessed in the surviving patients with a minimal 5-year followup (170 patients, 184 hips). At the median followup of 7.8 years, the average Merle d'Aubigne and Postel score had improved from 11.9- to 17.7. Results were graded as excellent in 148 hips (80.5%), very good in 31 hips (17%), good in two hips (1%), and fair in three hips (1.5%), Radiologic data were documented for 134 patients (143 hips). Three sockets (2%) had a complete and nonprogressive radiolucent line less than I-mm thick, one stem (0.7%) had lucencies involving five zones, and two stems (1.4%) had isolated femoral osteolysis, Neither component migration nor acetabular osteolysis were detected. A press-fit metal-backed socket may offer a good solution for alumina socket fixation when combined with a careful surgical technique of implantation.
引用
收藏
页码:134 / 142
页数:9
相关论文
共 50 条
  • [31] Preliminary results of the 5-year study of outpatient psychosomatic followup care
    Kobelt, A
    Grosch, E
    Lamprecht, F
    Künsebeck, HW
    Hentschel, HJ
    Schmid-Ott, G
    [J]. PSYCHOTHERAPIE PSYCHOSOMATIK MEDIZINISCHE PSYCHOLOGIE, 2004, 54 (02) : 98 - 98
  • [32] A 5-year followup study of asymptomatic men with testicular microlithiasis - Comment
    Nargund, Vinod H.
    [J]. JOURNAL OF UROLOGY, 2008, 179 (04): : 1423 - 1423
  • [33] 5-Jahres-Ergebnisse der zementfreien Allofit®-Press-fit-PfanneFive-year survival rate of the Allofit titanium press-fit cup
    K. Schroeder
    A. Moehlenbruch
    M. Zimmermann-Stenzel
    D. Parsch
    [J]. Der Orthopäde, 2010, 39 (1): : 87 - 91
  • [34] The influence of chronic inflammation in prostatic carcinogenesis: A 5-year followup study
    MacLennan, Gregory T.
    Eisenberg, Rosana
    Fleshman, Ranleigh L.
    Taylor, J. Michael
    Fu, Pingfu
    Resnick, Martin I.
    Gupta, Sanjay
    [J]. JOURNAL OF UROLOGY, 2006, 176 (03): : 1012 - 1016
  • [35] Primary antiphospholipid syndrome: A 5-year transesophageal echocardiographic followup study
    Zavaleta, NE
    Montes, RM
    Soto, ME
    Vanzzini, NA
    Amigo, MC
    [J]. JOURNAL OF RHEUMATOLOGY, 2004, 31 (12) : 2402 - 2407
  • [36] ILEAL CONDUIT AND CYSTECTOMY - 10-YEAR RETROSPECTIVE STUDY OF ILEAL CONDUITS PERFORMED IN CONJUNCTION WITH CYSTECTOMY AND WITH A MINIMUM 5-YEAR FOLLOWUP
    DAUGHTRY, JD
    SUSAN, LP
    STEWART, BH
    STRAFFON, RA
    [J]. JOURNAL OF UROLOGY, 1977, 118 (04): : 556 - 557
  • [37] 5-to 8-year results of the Freeman press-fit hip arthroplasty without HA coating - A clinicoradiologic study
    Menon, DK
    McCreath, SW
    [J]. JOURNAL OF ARTHROPLASTY, 1999, 14 (05): : 581 - 588
  • [38] Reply to the Letter to the Editor: No Difference Between Trabecular Metal Cones and Femoral Head Allografts in Revision TKA: Minimum 5-year Followup
    Sandiford, Nemandra A.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2018, 476 (05) : 1121 - 1121
  • [39] Cementless porous-coated sockets without holes implanted with pure press-fit technique - Average 6-year follow-up
    Spak, RT
    Stuchin, SA
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (01): : 4 - 10
  • [40] Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: Average ten-year follow-up
    Udomkiat, P
    Dorr, LD
    Wan, ZN
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (07): : 1195 - 1200