An experimental investigation of a double pass solar air heater performance: A comparison between natural and forced air circulation processes

被引:48
|
作者
Salih, Mothana M. Mohamed [1 ]
Alomar, Omar Rafae [1 ]
Ali, Firas Aziz [1 ]
Maher, Abd Hareth [1 ]
机构
[1] Northern Tech Univ, Engn Tech Coll Mosul, Cultural Grp St, Mosul, Iraq
关键词
Natural and forced convection; Double-pass air solar collector; Solar radiation; Two air passages; THERMAL PERFORMANCE; ABSORBER PLATE; DESIGN; ENERGY;
D O I
10.1016/j.solener.2019.09.060
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This work involves an experimental study on a trapezoidal Double-Pass Solar Air Heater (DPSAH) to analyse its performance under natural and forced convection cases for the purpose of comparison. The experiments have been conducted in winter and compared for each case in same time and weather conditions. The collector has been carefully designed and constructed to prevent as possible the heat losses. A uniform fins have been fixed on both sides of the absorber plate to enhance the heat exchange rate. Effects of solar radiation and air mass flowrate on DPSAH performance have been investigated. The results show that DPSAH produces higher efficiency when the system is operated under natural convection case in comparison to forced convection case. The maximum efficiency has been found equal to 73.5% and 65% for natural and forced convection, respectively. A significant temperature difference has been obtained under natural convection case compared to forced convection. The results confirmed that DPSAH with adding fins leads to considerable performance improvement compared to conventional DPSAH due to enhance the absorbing solar energy caused by increasing surface area. The increasing in air mass flowrate has inverse influence on the performance of DPSAH. For natural circulation case, the outlet, plate and glass temperatures have been always observed higher than the forced convection case. It is evident that type of heat transfer has considerably affect the system performance and consequently, the selection of air circulation process are required to be satisfactorily chosen according to the application to achieve the desired objective.
引用
收藏
页码:184 / 194
页数:11
相关论文
共 50 条
  • [11] Experimental investigation of single pass solar air heater with reflectors and turbulators
    Abdullah, A. S.
    Amro, M., I
    Younes, M. M.
    Omara, Z. M.
    Kabeel, A. E.
    Essa, F. A.
    ALEXANDRIA ENGINEERING JOURNAL, 2020, 59 (02) : 579 - 587
  • [12] Study of the performance of double pass solar air heater of a new designed absorber: An experimental work
    Abo-Elfadl, Saleh
    Hassan, Hamdy
    El-Dosoky, M. F.
    SOLAR ENERGY, 2020, 198 : 479 - 489
  • [13] Thermal performance of a packed bed double pass solar air heater with a latent heat storage system: an experimental investigation
    Dosapati, Chaitanya
    Mandapati, Mohan Jagadeesh Kumar
    WORLD JOURNAL OF ENGINEERING, 2019, 17 (02) : 203 - 213
  • [14] Experimental and simulation studies on a single pass, double duct solar air heater
    Forson, FK
    Nazha, MAA
    Rajakaruna, H
    ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (08) : 1209 - 1227
  • [15] Experimental investigation of the performance of a double pass solar water heater with reflector
    Mandal, Soumya
    Ghosh, Subir Kumar
    RENEWABLE ENERGY, 2020, 149 : 631 - 640
  • [16] Effect of Tubular Solar Absorber on Performance of Counterflow Double Pass Solar Air Heater: Experimental and Numerical Studies
    Hussein, N.F.
    Ahmed, S.T.
    Ekaida, A.L.
    International Journal of Engineering, Transactions B: Applications, 2022, 35 (10): : 2007 - 2017
  • [17] Effect of Tubular Solar Absorber on Performance of Counterflow Double Pass Solar Air Heater: Experimental and Numerical Studies
    Hussein, N.F.
    Ahmed, S.T.
    Ekaid, A.L.
    International Journal of Engineering, Transactions A: Basics, 2022, 35 (10): : 2007 - 2017
  • [18] Experimental investigation of a double pass converging finned wire mesh packed bed solar air heater
    Singh, Satyender
    Dhruw, Laxmikant
    Chander, Subhash
    JOURNAL OF ENERGY STORAGE, 2019, 21 : 713 - 723
  • [19] Effect of Tubular Solar Absorber on Performance of Counterflow Double Pass Solar Air Heater: Experimental and Numerical Studies
    Hussein, N. F.
    Ahmed, S. T.
    Ekaid, A. L.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2022, 35 (10): : 2007 - 2017
  • [20] Experimental investigation on the performance of an impinging jet solar air heater
    Rajaseenivasan, T.
    Prasanth, S. Ravi
    Antony, M. Salamon
    Srithar, K.
    ALEXANDRIA ENGINEERING JOURNAL, 2017, 56 (01) : 63 - 69