Performance investigation of zero-building-integrated photovoltaic roof system: A case study in Egypt

被引:19
|
作者
Megahed, Tamer F. [1 ,2 ]
Radwan, Ali [3 ]
机构
[1] Egypt Japan Univ Sci & Technol, Elect Power Engn, Alexandria 21934, Egypt
[2] Mansoura Univ, Elect Power Engn Dept, Fac Engn, Mansoura 35516, Egypt
[3] Mansoura Univ, Dept Power Mech Engn, Fac Engn, Mansoura 35516, Egypt
关键词
Photovoltaic; 3D thermal model; Inverters; Batteries; Cost analysis; Maximum power tracking; PV; TECHNOLOGY;
D O I
10.1016/j.aej.2020.09.031
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The concept of zero-energy buildings was developed due to the high cost of electricity and the availability of renewable energy. This study presents detailed design steps for a zero building using a grid-connected photovoltaic (PV) system with a battery to supply the load demand for a building in Egypt (31.0409 degrees N, 31.3785 degrees E). In the system design, the sizes of the system components are determined, including the sizes of the PV cells, batteries, chargers, and controllers, such that they fulfill the load requirements. Maximum power tracking is designed to achieve maximum utilization of solar energy. In addition, a cooling model for the PV system is introduced to increase its efficiency. The PV performance with and without the thermal absorber is theoretically investigated and compared using a three-dimensional conjugate heat transfer model. A coupled thermal-electrical iterative model is also used to estimate the system's hourly performance. Findings show that increasing the cooling flow rate for the proposed PV system from 0 L/min to 1 L/min significantly decreases the temperature of the PV module from 60 degrees C to 41 degrees C at a solar radiation of 650 W/m(2). The theoretical results show that using the PV thermal technology at a coolant flow rate of 2 L/min /module generates the highest electrical power along with enough thermal energy for residential building heating. The outlet warm water from the cooling process has been used household uses to achieve a zero-building theory. This thermal energy can also be used in floor heating radiant systems with high energy efficiency and good thermal comfort. Furthermore, the proposed system can sell 33.5 and 61.9 kWh energy to the grid per day in summer and winter, respectively. (C) 2020 The Authors. Published by Elsevier B.V. on behalf of Faculty of Engineering, Alexandria University.
引用
收藏
页码:5053 / 5067
页数:15
相关论文
共 50 条
  • [31] Towards a Net Zero Building Using Photovoltaic Panels: A Case Study in an Educational Building
    Dhakal, Rabin
    Sedai, Ashish
    Paneru, Suman
    Yosofvand, Mohammad
    Moussal, Hanna
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2021, 11 (02): : 879 - 889
  • [32] Simulation Modeling of a Photovoltaic-Green Roof System for Energy Cost Reduction of a Building: Texas Case Study
    Kim, Sojung
    Aydin, Burchan
    Kim, Sumin
    ENERGIES, 2021, 14 (17)
  • [33] Study on Energy Payback Time of Building Integrated Photovoltaic System
    Huang, Dikai
    Yu, Tai
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1087 - 1092
  • [34] Experimental study of ventilated building integrated photovoltaic/ thermal system
    Ma, Li-Qun
    Zhao, Yu-Long
    Zhao, Yun-Tong
    Wang, Shi-Xue
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2022, 56 (11): : 2168 - 2174
  • [35] Development and Performance of Roof-Based Building-Integrated Photovoltaic-Thermal Systems: A Review
    Cheng, Xu
    Zou, Zhijun
    Yu, Guoqing
    Ma, Guobin
    Ye, Hai
    Li, Yilin
    Liu, Hongzhi
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2021, 143 (04):
  • [36] Performance modeling and testing of a Building Integrated Concentrating Photovoltaic (BICPV) system
    Baig, Hasan
    Sellami, Nazmi
    Mallick, Tapas K.
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2015, 134 : 29 - 44
  • [37] Evaluation Study Design and Operation of a Building Integrated Photovoltaic System
    Mosalam, Heba
    2018 6TH IEEE INTERNATIONAL CONFERENCE ON SMART GRID (ICSMARTGRIDS), 2018, : 195 - 201
  • [38] Electrical performance results of an energy efficient building with an integrated photovoltaic system
    Ziuku, Sosten
    Meyer, Edson L.
    JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2010, 21 (03) : 2 - 8
  • [39] Design and performance analysis of a novel office building integrated photovoltaic system
    Wang, Gang
    Cao, Fan
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 10964 - 10979
  • [40] Investigation of the role of cavity airflow on the performance of building-integrated photovoltaic panels
    Mirzaei, Parham A.
    Paterna, Enrico
    Carmeliet, Jan
    SOLAR ENERGY, 2014, 107 : 510 - 522