Adjuvant vaginal cuff brachytherapy: dosimetric comparison of conventional versus 3-dimensional planning in endometrial cancer

被引:8
|
作者
Gultekin, Melis [1 ]
Yilmaz, Melek Tugce [1 ]
Biltekin, Fatih [1 ]
Yuce, Deniz [2 ]
Sari, Sezin Yuce [1 ]
Akyol, Fadil [1 ]
Yildiz, Ferah [1 ]
机构
[1] Hacettepe Univ, Fac Med, Dept Radiat Oncol, TR-06100 Ankara, Turkey
[2] Hacettepe Univ, Fac Med, Dept Prevent Oncol, Ankara, Turkey
关键词
endometrial cancer; brachytherapy; vaginal cuff brachytherapy; three-dimensional planning; dosimetric comparison; POSTOPERATIVE RADIATION-THERAPY; IMAGE-GUIDED BRACHYTHERAPY; EXTERNAL-BEAM RADIOTHERAPY; DOSE-RATE BRACHYTHERAPY; QUALITY-OF-LIFE; AMERICAN SOCIETY; CARCINOMA; RECOMMENDATIONS; GUIDELINES; PORTEC-2;
D O I
10.5114/jcb.2020.101694
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate dosimetric differences between point-based 2-dimensional (2D) vaginal brachytherapy (VBT) treatment planning technique and volume-based 3-dimensional (3D) VBT method for endometrial cancer (EC). Material and methods: Ten patients with uterine-confined EC treated with VBT were included in this study. All patients received 27.5 Gy in 5 fractions. Three different treatment plans were performed for each patient: plan A for dose prescribed to the entire vaginal wall thickness delineated via computed tomography guidance, plan B for dose prescribed to the vaginal mucosa/cylinder surface, and plan C for dose prescribed to 5 mm beyond the vaginal mucosa/cylinder surface. Dose-volume histograms (DVH) of treatment volumes and organs at risk (OARs) were evaluated and compared. Results: DVH analysis of target volume doses (D-100, D-95, and D-90) showed a significant difference between plan A and plan B (p = 0.005), and plan B was found lower. D-100 for plan C was significantly higher than plan A (p = 0.009), but for D-95 and D-90, no statistically significant difference was found (p = 0.028 and p = 0.028, respectively). In terms of OARs doses, including vagina, rectum, bladder, and sigmoid, D-2cm3 doses were significantly higher in plan A than plan B (p = 0.009, p = 0.009, p = 0.005, and p = 0.005, respectively). All these doses were also significantly lower than in plan C (p = 0.005, p = 0.012, and p = 0.013, respectively), except for sigmoid (p = 0.155). Conclusions: In this dosimetric analysis, we have shown that the volume-based 3D VBT technique provides the ability to balance the target dose against the sparing of OARs. Therefore, in the new modern 3D treatment era, instead of normalization of the dose to standard reference points, customized 3D volume-based VBT planning should be recommended.
引用
收藏
页码:601 / 605
页数:5
相关论文
共 50 条
  • [41] Evaluating the relationship between vaginal apex ?dog ears? and patterns of recurrence in endometrial cancer following adjuvant image guided vaginal cuff brachytherapy
    Venner, Emily K.
    Ward, Kristin A.
    Wages, Nolan A.
    Walker, Bryant
    Libby, Bruce P.
    Showalter, Timothy N.
    Romano, Kara D.
    BRACHYTHERAPY, 2023, 22 (02) : 139 - 145
  • [42] Is There Any Advantage to 3D Planning for Vaginal Cuff Brachytherapy?
    Kim, H.
    Kim, H.
    Beriwal, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S474 - S474
  • [43] Dosimetric Comparison of 3-Dimensional Conformal and Intensity-Modulated Radiotherapy Planning Techniques in Breast Cancer
    Sirin Ozdemir, Beyza
    Kirecci, Orkun
    UHOD-ULUSLARARASI HEMATOLOJI-ONKOLOJI DERGISI, 2019, 29 (04): : 191 - 197
  • [44] Dosimetric impact of bladder filling on organs at risk with barium contrast in the small bowel for adjuvant vaginal cuff brachytherapy
    Salas Buzon, Maria del Carmen
    Gutierrez Bayard, Lucia
    Rodriguez Sanchez, Raquel
    Quinones Rodriguez, Luis Angel
    Sayago Gil, Sarah
    Munoz Higueras, Cristina
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2021, 13 (06) : 655 - 662
  • [45] Dosimetric evaluation of different cylinder diameters in three-dimensional vaginal brachytherapy for early-stage endometrial cancer
    Wang, Kaiyue
    Jiang, Ping
    Wang, Junjie
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2024, 150 (12)
  • [46] Are outcomes of adjuvant vaginal vault brachytherapy in endometrial cancer related to the way it is delivered?
    Alzouebi, M.
    Pledge, S. D.
    Martin, J. E.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2012, 11 (03) : 170 - 183
  • [47] RESULTS OF EXCLUSIVE ADJUVANT VAGINAL BRACHYTHERAPY IN INTERMEDIATE-RISK ENDOMETRIAL CANCER
    Coza, O.
    Gavris, S.
    Ordeanu, C.
    Bako, M.
    Irimie, A.
    Eniu, D.
    Rancea, A.
    Hica, S.
    Coza, D.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S268 - S268
  • [48] Vaginal cuff brachytherapy for endometrial cancer: a review of major clinical trials with a focus on fractionation
    Parsons, Matthew W.
    Huang, Y. Jessica
    Burt, Lindsay
    Suneja, Gita
    Gaffney, David
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2022, 32 (03) : 311 - 315
  • [49] Clinical outcome and toxicity of MRI-based vaginal cuff brachytherapy in endometrial cancer
    Jaisawang, C.
    Alisanant, P.
    Shotelersuk, K.
    Khorprasert, C.
    Amornwichet, N.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S807 - S808
  • [50] Dosimetric comparison of conventional whole-brain radiotherapy with 3-dimensional conformal radiotherapy
    Fakhrian, K.
    Lateit, T.
    Buehler, H.
    Qweider, M.
    Strohm, G. L.
    Adamietz, I. A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 : 143 - 143