Experimental study on flame pulsation behavior of external venting facade fire ejected from opening of a compartment

被引:22
|
作者
Sun, Xiepeng [1 ]
Hu, Longhua [1 ]
Zhang, Xiaolei [1 ]
Ren, Fei [1 ]
Yang, Yong [1 ]
Fang, Xiang [1 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
External venting facade fire (EVF) of compartment; Flame pulsation magnitude; Flame pulsation frequency (f); Strouhal number (St ); Froude number (Fr ); BUOYANT PLUMES; POOL;
D O I
10.1016/j.proci.2020.06.181
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present study investigated experimentally the flame pulsation magnitude (ratio of maximum flame height to mean flame height; ratio of mean flame height to continuous flame height) and flame pulsation frequency of the external venting facade fire (EVF) ejected from opening of a compartment. Experiments were conducted by employing three model-scale fire compartments with an opening and a vertical facade wall. Fifteen different opening geometries were considered. For the flame pulsation magnitude of EVF, results showed that the ratio of maximum flame height to the mean flame height was about 1.30, while the ratio of mean flame height to continuous flame height was about 1.60; both of them were independent of opening geometries and heat release rates. The flame pulsation frequency of EVF increased with increasing of heat release rate, meanwhile decreased with increasing of opening size (or namely opening characteristic lengths: l(1)= (AH(1/2))(2/5); l(2) = (AH(2))(1/4)). The measured flame pulsation frequency of EVF showed to be much lower than the predicted values by previous classic models developed for free buoyant diffusion flames, which is due to physically the inherent special exit condition (with initial horizontal convection flow of heat) at the opening for EVF. A new formula was proposed for the flame pulsation frequency of EVF in terms of a non-dimensional function between Strouhal number (St) and Froude number (Fr), using V-f proportional to root gZ(f) as the characteristic flame uprising velocity and l(1)= (AH(1/2))(2/5) as the characteristic length of the source exit convection flow condition at the opening. The flame pulsation frequency showed to be well represented by the proposed formula. These new observations and the proposed formula provide essential knowledge for the characterization of flame pulsation behavior of external venting facade fire (EVF) ejected through the opening of a compartment. (C) 2020 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:4485 / 4493
页数:9
相关论文
共 50 条
  • [41] A global non-dimensional factor characterizing side wall constraint effect on facade flame entrainment and flame height from opening of compartment fires
    Hu, L.H.
    Lu, K.H.
    Tang, F.
    Delichatsios, M.
    He, L.H.
    International Journal of Heat and Mass Transfer, 2014, 75 : 122 - 129
  • [42] A global non-dimensional factor characterizing side wall constraint effect on facade flame entrainment and flame height from opening of compartment fires
    Hu, L. H.
    Lu, K. H.
    Tang, F.
    Delichatsios, M.
    He, L. H.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 75 : 122 - 129
  • [43] An Experimental and Modeling Study on the Effect of Wall Opening Location on the Under-Ventilated Compartment Fire
    Wang, Lujia
    Park, Haejun
    SUSTAINABILITY, 2022, 14 (19)
  • [44] Preliminary experimental study of horizontal opening effect on pool fire behavior
    Chen, Xiao
    Lu, Shouxiang
    Liew, Kim Meow
    12TH INTERNATIONAL CONFERENCE ON COMBUSTION & ENERGY UTILISATION, 2015, 66 : 181 - 184
  • [45] Experimental Investigation on the Vertical Temperature Profile of Spilled Plume from a Compartment-Facade Fire with a Horizontal Projection
    Mao, Shaohua
    Liu, Shishan
    Hu, Yangyang
    Xu, Huasheng
    Xiang, Yanqing
    Lu, Kaihua
    FIRE TECHNOLOGY, 2024, 60 (02) : 1269 - 1286
  • [46] EXPERIMENTAL-STUDY ON OSCILLATING BEHAVIOR IN A SMALL-SCALE COMPARTMENT FIRE
    KIM, KI
    OHTANI, H
    UEHARA, Y
    FIRE SAFETY JOURNAL, 1993, 20 (04) : 377 - 384
  • [47] Fire spread along vertical greenery systems from window ejected flame: A study based on a fire dynamic simulator model
    Karunaratne, Tharindu Lakruwan Wickremanayake
    Chow, Cheuk Lun
    JOURNAL OF BUILDING ENGINEERING, 2022, 62
  • [48] Experimental study on flame height and temperature profile of buoyant window spill plume from an under-ventilated compartment fire
    Tang, F.
    Hu, L. H.
    Delichatsios, M. A.
    Lu, K. H.
    Zhu, W.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (1-3) : 93 - 101
  • [49] Experimental study on flame length and pulsation behavior of n-heptane continuous spill fires on water
    Zhao, Jinlong
    Song, Guangheng
    Zhang, Qingyuan
    Li, Xinjiang
    Huang, Hong
    Zhang, Jianping
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2023, 85
  • [50] An investigation of horizontal opening effect on pool fire behavior in a confined compartment: A study based on global equivalence ratio
    Chen, Xiao
    Lu, Shouxiang
    Liew, Kim Meow
    JOURNAL OF FIRE SCIENCES, 2016, 34 (01) : 13 - 29