Effects of end distance on thin sheet steel bolted connections

被引:21
|
作者
Cai, Yancheng [1 ]
Young, Ben [1 ,2 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Pokfulam Rd, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
关键词
Bearing failure; Bolted connection; End distance; Thin-walled plates; Tearout failure; ELEVATED-TEMPERATURES; SECTION COLUMNS; BEARING FACTORS; BEHAVIOR; STRENGTH; TESTS;
D O I
10.1016/j.engstruct.2019.109331
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effects of end distance on thin sheet steel (TSS) bolted connections were investigated experimentally. The TSS grades G450, G500 and G550, with the respective nominal thicknesses of 1.90 mm, 1.20 mm and 0.42 mm, were used to fabricate the connection specimens. The connection specimens were assembled by one bolt in both single shear and double shear. The connection specimens in the single shear and double shear were designed in 5 series with different ratios of bolt diameter to connection plate thickness. In each series, the end distance of the connection specimen was varied. The connection specimens were subjected to tensile loading using the displacement control test method. The effects of end distance on the behavior of the specimens were obtained, including ultimate loads and failure modes. It was found that the ultimate loads were increased when the end distances were increased up to three times and five times the bolt diameter for single shear and double shear, respectively. Furthermore, the tearout failure mode progressed to bearing failure mode with the increment of the end distance. The experimental results were compared with the predicted nominal strengths and failure modes by using the Australian/New Zealand Standard (AS/NZS), North American Specification (NAS) and European Code (EC3-1.3) for cold-formed steel structures. Overall, it is found that both the NAS and EC3-1.3 specifications generally provide conservative predictions, while the AS/NZS generally provides unconservative predictions. However, the reliability analysis showed that the design provisions of AS/NZS are reliable and probabilistically safe for the TSS bolted connections in this study. The AS/NZS, NAS and EC3-1.3 generally predict accurate failure modes of the specimens. However, the EC3-1.3 provides more accurate predictions when specimens fail in plate bearing.
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [21] Mechanical behavior of loose high-strength bolted connections with thin sheet steels
    Xue, Xiaolei
    Lin, Shentong
    Guo, Zhan
    Zhao, Yang
    Lin, Quan
    Chen, Yu
    THIN-WALLED STRUCTURES, 2021, 168
  • [22] Bearing factors for single shear bolted connections of thin sheet steels at elevated temperatures
    Yan, Shu
    Young, Ben
    THIN-WALLED STRUCTURES, 2012, 52 : 126 - 142
  • [23] Development of bolted end plate connections for steel reinforced concrete composite structures
    Xiao, Y
    Anderson, JC
    Wu, YT
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 785 - 792
  • [24] Effect of end distance and bolt number on bearing strength of bolted connections at elevated temperature
    Kuo-Chen Yang
    Re-Jia Hsu
    Chiung-Fang Hsu
    International Journal of Steel Structures, 2013, 13 : 635 - 644
  • [25] Effect of End Distance and Bolt Number on Bearing Strength of Bolted Connections at Elevated Temperature
    Yang, Kuo-Chen
    Hsu, Re-Jia
    Hsu, Chiung-Fang
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2013, 13 (04) : 635 - 644
  • [26] Finite element modelling of thin sheet steel screw connections
    Rautenbach, E.
    van Rensburg, B. W. J.
    INSIGHTS AND INNOVATIONS IN STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION, 2016, : 1253 - 1258
  • [27] BOLTED FRICTION CONNECTIONS WITH WEATHERING STEEL
    Yura, Joseph A.
    Frank, Karl H.
    Cayes, Lloyd
    1981, 107 (11): : 2071 - 2087
  • [28] BOLTED FRICTION CONNECTIONS WITH WEATHERING STEEL
    YURA, JA
    FRANK, KH
    CAYES, L
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1981, 107 (11): : 2071 - 2087
  • [29] Shear Strength of a Cold-Formed Steel Sheet in Bolted Connections Using Oversized Holes
    Yu, Cheng
    Xu, Ke
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2013, 139 (05): : 860 - 864
  • [30] Behaviour of bolted end-plate connections to concrete-filled steel columns
    Tao, Zhong
    Li, Wei
    Shi, Bo-Lin
    Han, Lin-Hai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 134 : 194 - 208