An Assessment of Airborne Fungi Exposure Risk Level in Air-conditioned Offices

被引:12
|
作者
Wong, L. T. [1 ]
Chan, W. Y. [1 ]
Mui, K. W. [1 ]
Hui, P. S. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
Indoor air quality; Airborne fungi; Risk assessment; Relative index of fungal exposure (RIFE); INDOOR AIR; SUBTROPICAL CLIMATES; HONG-KONG; BUILDINGS; SYSTEMS; MYCOTOXINS; ALLERGENS; QUALITY; MODEL; MOLD;
D O I
10.1177/1420326X09347061
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The exposure to airborne fungi has not been included in many regular indoor air quality (IAQ) assessments of air-conditioned (A/C) offices. This study examined the feasibility of using a proposed relative index of fungal exposure (RIFE) as a quantitative measure to specify the enclosure effect of an indoor environment in 82 Hong Kong A/C offices. The airborne fungi count ranged from 2 to 92 CFU.m(-3). Yeast, Aspergillus, Cladosporium, and Penicillium were reported as dominant in the offices. The RIFE of Yeast, Aspergillus, and Penicillium were 1.26, 1.21, and 1.02, respectively, and it would confirm a higher indoor exposure risk relative to that of outdoors. The RIFE of the common outdoor fungi Cladosporium was 0.48. This study presents a useful index for IAQ assessment regarding relative risk exposure of airborne fungi in A/C offices.
引用
收藏
页码:553 / 561
页数:9
相关论文
共 50 条
  • [41] Bayesian assessments for acceptable airborne bacteria levels in air-conditioned spaces
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    Chan, W. Y.
    INDOOR AND BUILT ENVIRONMENT, 2008, 17 (01) : 80 - 86
  • [42] MEASUREMENT OF AIRBORNE RADON CONCENTRATION IN AIR-CONDITIONED BUILDING BY USING SSNTD
    LU, YQ
    FENG, YH
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 383 - 385
  • [43] Recurrent exposure to Histoplasma capsulatum in modern air-conditioned buildings
    Luby, JP
    Southern, PM
    Haley, CE
    Vahle, KL
    Munford, RS
    Haley, RW
    CLINICAL INFECTIOUS DISEASES, 2005, 41 (02) : 170 - 176
  • [44] Occupant perceptions on the thermal comfort guidelines in air-conditioned offices in Colombo, Sri Lanka
    Rodrigo, G. A.
    Perera, B. A. K. S.
    Ekanayake, B. J.
    INTERNATIONAL JOURNAL OF CONSTRUCTION MANAGEMENT, 2022, 22 (04) : 579 - 587
  • [45] A TALE OF 2 POPULATIONS - THERMAL COMFORT IN AIR-CONDITIONED AND NATURALLY VENTILATED OFFICES IN THAILAND
    BUSCH, JF
    ENERGY AND BUILDINGS, 1992, 18 (3-4) : 235 - 249
  • [46] The Relation between Clothing Insulation and Thermal Comfort of Occupants in Air-Conditioned Offices in Thailand
    Sikram, Tanadej
    Ichinose, Masayuki
    Sasaki, Rumiko
    SMART AND HEALTHY WITHIN THE TWO-DEGREE LIMIT (PLEA 2018), VOL 3, 2018, : 991 - 992
  • [47] AIRBORNE MICROBIAL CONTAMINANTS IN INDOOR ENVIRONMENTS - NATURALLY VENTILATED AND AIR-CONDITIONED HOMES
    KODAMA, AM
    MCGEE, RI
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1986, 41 (05): : 306 - 311
  • [48] AIRBORNE INFECTION IN A FULLY AIR-CONDITIONED HOSPITAL .1. AIR TRANSFER BETWEEN ROOMS
    FOORD, N
    LIDWELL, OM
    JOURNAL OF HYGIENE, 1975, 75 (01) : 15 - 30
  • [49] Isolation, identification and testing for allergenicity of fungi from air-conditioned indoor environments
    Khan, A. A. Haleem
    Karuppayil, S. Mohan
    Manoharachary, C.
    Kunwar, I. K.
    Waghray, S.
    AEROBIOLOGIA, 2009, 25 (02) : 119 - 123
  • [50] Occupant comfort in naturally ventilated and mixed-mode spaces within air-conditioned offices
    Drake, Scott
    de Dear, Richard
    Alessi, Angela
    Deuble, Max
    ARCHITECTURAL SCIENCE REVIEW, 2010, 53 (03) : 297 - 306