Distal biceps tendon rupture: Biomechanical analysis of repair strength of the Bio-Tenodesis screw versus suture anchors

被引:46
|
作者
Krushinski, Erik M. [1 ]
Brown, John A. [1 ]
Murthi, Anand M. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Orthopaed, Shoulder & Elbow Serv, Baltimore, MD 21201 USA
关键词
D O I
10.1016/j.jse.2006.05.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to compare the strength and stiffness of distal biceps tendon ruptures repaired with either a Bio-Tenodesis screw or suture anchor technique in a cadaveric model. Ten matched pairs of cadaveric arms underwent simulated distal biceps tendon ruptures and were repaired with either a Bio-Tenodesis screw or suture anchor technique. We analyzed pullout strength, stiffness, and mode of failure for each construct. The mean pullout strength of the repair with a Bio-Tenodesis screw was significantly higher (192 N [SD, 42.5 N] vs 147 N [SD, 29.5 N], P <.013). Use of the Bio-Tenodesis screw is an effective means of repairing distal biceps tendon ruptures. It provides significantly more initial pullout strength compared with suture anchors. This could potentially allow more aggressive rehabilitation and faster return to function.
引用
收藏
页码:218 / 223
页数:6
相关论文
共 50 条
  • [1] Repair of distal biceps tendon rupture with suture anchors
    Lynch, SA
    Beard, DM
    Renström, PAFH
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (02) : 125 - 131
  • [2] Repair of distal biceps tendon rupture with suture anchors
    Scott A. Lynch
    David M. Beard
    P. A. F. H. Renström
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 1999, 7 : 125 - 131
  • [3] Biomechanical Comparison of Onlay Distal Biceps Tendon Repair: All-Suture Anchors Versus Titanium Suture Anchors
    Otto, Alexander
    Mehl, Julian
    Obopilwe, Elifho
    Cote, Mark
    Lacheta, Lucca
    Scheiderer, Bastian
    Imhoff, Andreas B.
    Mazzocca, Augustus D.
    Siebenlist, Sebastian
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (10): : 2478 - 2483
  • [4] Double intramedullary cortical button versus suture anchors for distal biceps tendon repair: a biomechanical comparison
    Sebastian Siebenlist
    Arne Buchholz
    Julian Zapf
    Gunther H. Sandmann
    Karl F. Braun
    Frank Martetschläger
    Alexander Hapfelmeier
    Tobias M. Kraus
    Andreas Lenich
    Peter Biberthaler
    Florian Elser
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 926 - 933
  • [5] Double intramedullary cortical button versus suture anchors for distal biceps tendon repair: a biomechanical comparison
    Siebenlist, Sebastian
    Buchholz, Arne
    Zapf, Julian
    Sandmann, Gunther H.
    Braun, Karl F.
    Martetschlaeger, Frank
    Hapfelmeier, Alexander
    Kraus, Tobias M.
    Lenich, Andreas
    Biberthaler, Peter
    Elser, Florian
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (03) : 926 - 933
  • [6] Repair of distal biceps tendon rupture with the Biotenodesis screw
    Khan, W
    Agarwal, M
    Funk, L
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (03) : 206 - 208
  • [7] Repair of distal biceps tendon rupture with the Biotenodesis screw
    W. Khan
    M. Agarwal
    L. Funk
    [J]. Archives of Orthopaedic and Trauma Surgery, 2004, 124 : 206 - 208
  • [8] Proximal versus distal screw placement for biceps tenodesis: a biomechanical study
    De Villiers, Daniel Johannes
    Loh, Brian
    Tacey, Mark
    Keith, Prue
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2016, 24 (02) : 258 - 261
  • [9] Repair of the distal biceps tendon using suture anchors and an anterior approach
    Lintner, S
    Fischer, T
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (322) : 116 - 119
  • [10] A biomechanical comparison of EndoButton versus suture anchor repair of distal biceps tendon injuries
    Spang, Jeffrey T.
    Weinhold, Paul S.
    Karas, Spero G.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (04) : 509 - 514