Factors affecting microbiological quality of household drinking water supplied by small-scale ultrafiltration systems: A field study

被引:8
|
作者
Zhang, Xiaolei [1 ]
He, Yankun [1 ]
Zhang, Beichen [1 ]
Qin, Lanlan [1 ]
Yang, Qing [1 ]
Huang, Haiou [1 ]
机构
[1] Beijing Normal Univ, Sch Environm, State Key Joint Lab Environm Simulat & Pollut Con, Beijing 100875, Peoples R China
关键词
Drinking water; Microbiological quality; Rural area; Secondary contamination; Ultrafiltration; BACTERIA; DISINFECTION;
D O I
10.1016/j.scitotenv.2019.06.327
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Small scale ultrafiltration (UF) systems have been increasingly used in rural areas for drinking water supply, but their effectiveness in guarantying microbiological water safety at household level has rarely been assessed. Therefore, this study surveyed six representative villages where UF was utilized for full-scale chinking water supply for at least four years. At each village, the influent and the effluent from every stages of the treatment, as well as household tap water, were sampled and analyzed for microbiological indicating parameters, including total coliform count, Escherichia toff count, and heterotrophic plate count. The results were further assessed against current drinking water quality guidelines and standards. It was found that: (1) the qualification rate of household tap water samples varied substantially in the studied villages (0-75%), mainly due to the lack of post disinfection and the occurrence of fecal contamination during water distribution; (2) UP appeared to be effective in controlling microbial contamination for small-scale systems with high-quality source water, while for systems using inferior source water, fecal contamination during water distribution necessitated continuous post disinfection; and, (3) existing monitoring of membrane operational parameters cannot ensure microbial quality of treated water, and therefore, routine monitoring of microbial indicators in household water is recommended. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:725 / 733
页数:9
相关论文
共 35 条
  • [31] Study on the factors affecting simultaneous removal of ammonia and manganese by pilot-scale biological aerated filter (BAF) for drinking water pre-treatment
    Han, Mei
    Zhao, Zhi-wei
    Gao, Wei
    Cui, Fu-yi
    BIORESOURCE TECHNOLOGY, 2013, 145 : 17 - 24
  • [32] Improvement of Biogas Quality and Quantity for Small-Scale Biogas-Electricity Generation Application in off-Grid Settings: A Field-Based Study
    Wasajja, Henry
    Al-Muraisy, Saqr A. A.
    Piaggio, Antonella L.
    Ceron-Chafla, Pamela
    Aravind, Purushothaman Vellayani
    Spanjers, Henri
    van Lier, Jules B.
    Lindeboom, Ralph E. F.
    ENERGIES, 2021, 14 (11)
  • [33] Pilot study on arsenic removal from groundwater using a small-scale reverse osmosis system-Towards sustainable drinking water production (vol 318, pg 671, 2016)
    Schmidt, Stefan-Andre
    Gukelberger, Ephraim
    Hermann, Mario
    Fiedler, Florian
    Grossmann, Benjamin
    Hoinkis, Jan
    Ghosh, Ashok
    Chatterjee, Debashis
    Bundschuh, Jochen
    JOURNAL OF HAZARDOUS MATERIALS, 2017, 324 : 797 - 797
  • [34] 222Radon reduction in small-scale water supply systems using low-technology reduction methods in the Republic of Korea: A field research and mass balance model approach
    Kim, Youngyeon
    Jang, Youngho
    Kim, Hyeon
    Shin, Hyungsoon
    Singh, Rajendra
    Kim, Keugtae
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 869
  • [35] Water quality assessment of an artificial small-scale reservoir in the Moroccan Pre-Rif: a case study of Boudaroua Lake using multivariate statistical techniques and self-organizing maps
    En-nkhili, Hicham
    Igouzal, Mohammed
    Etebaai, Issam
    DESALINATION AND WATER TREATMENT, 2022, 260 : 279 - 290