Uncertainty in indoor air quality and grey system method

被引:31
|
作者
Zhu, Chihui
Li, Nianping [1 ]
Re, Di
Guan, Jun
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410081, Peoples R China
[2] Guangzhou Univ, Sch Civil Engn, Guangzhou 510006, Peoples R China
基金
中国国家自然科学基金;
关键词
indoor air quality; uncertainty; grey system theory;
D O I
10.1016/j.buildenv.2006.01.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Based on analysis of uncertainty, this paper presents grey system theory to handle the "grey" characteristic of IAQ. Grey comprehensive analysis of indoor air quality reveals that we should pay more attention to the air purification and humidity control in the design and maintenance of HVAC. In order to represent grey characteristic of IAQ system, the educed grey IAQ models can identify the variation intervals of key IAQ model parameters that are lack of directly measurable messages in practical Situations. Furthermore, grey assessment is an effective multifactor comprehensive assessment method that can express the integrative influence of contamination indexes on indoor air quality. We Can determine the IAQ grade and make comparison according to the grey incidence matrix R. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1711 / 1717
页数:7
相关论文
共 50 条
  • [41] A Novel Integrated Sensor System for Indoor Air Quality Measurement
    Masrie, Marianah
    Ahmad, Anuar
    Adnan, Ramli
    CSPA: 2009 5TH INTERNATIONAL COLLOQUIUM ON SIGNAL PROCESSING AND ITS APPLICATIONS, PROCEEDINGS, 2009, : 406 - +
  • [42] Agent-based Indoor Air Quality Control System
    Chen, Shang-Yuan
    SENSORS AND MATERIALS, 2019, 31 (05) : 1707 - 1726
  • [43] Indoor Air Quality Estimation by Using Smart Sensing System
    Kumar, Anuj
    Singh, I. P.
    Sud, S. K.
    IMECS 2009: INTERNATIONAL MULTI-CONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS, VOLS I AND II, 2009, : 1218 - 1220
  • [44] System to control indoor air quality in energy efficient buildings
    Mandayo, G. G.
    Gonzalez-Chavarri, J.
    Hammes, E.
    Newton, H.
    Castro-Hurtado, I
    Ayerdi, I
    Knapp, H.
    Sweetman, A.
    Hewitt, C. N.
    Castano, E.
    URBAN CLIMATE, 2015, 14 : 475 - 485
  • [45] Indoor Air Quality Assessment in an Art Gallery with an HVAC System
    Cai, Wei
    Wang, Danjun
    Wen, Xiaodong
    Yu, Xubo
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [46] Internet of things based indoor air quality improving system
    Shitole, Sanjay
    Nair, Devika
    Pandey, Nidhi
    Suhagiya, Heena
    2018 3RD INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2018,
  • [47] Air Quality System Using IoT for Indoor Environmental Monitoring
    AbdulWahhab, Rasha Shakir
    PROCEEDINGS OF THE 2019 5TH INTERNATIONAL CONFERENCE ON COMPUTER AND TECHNOLOGY APPLICATIONS (ICCTA 2019), 2019, : 184 - 188
  • [48] VAV system indoor air quality considerations for office spaces
    Zhang, PH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1365 - 1370
  • [49] A review on indoor air quality monitoring system: a mechatronics approach
    Kumar, S. Harish
    Kanish, T. C.
    AEROBIOLOGIA, 2024, 40 (03) : 373 - 390
  • [50] Air Quality Monitoring System for Indoor Environments using IoT
    Biswal, Amita
    Subhashini, J.
    Pasayat, Ajit Kumar
    11TH NATIONAL CONFERENCE ON MATHEMATICAL TECHNIQUES AND APPLICATIONS, 2019, 2112