Infant polysomnography: Reliability and validity of infant arousal assessment

被引:20
|
作者
Crowell, DH
Kulp, TD
Kapuniai, LE
Hunt, CE
Brooks, LJ
Weese-Mayer, DE
Silvestri, J
Ward, SD
Corwin, M
Tinsley, L
Peucker, M
机构
[1] John A Burns Sch Med, Dept Pediat, Honolulu, HI 96826 USA
[2] Kapiolani Med Ctr Women & Children, Honolulu, HI 96826 USA
[3] Childrens Hosp Los Angeles, Los Angeles, CA 90027 USA
[4] Rush Univ, Rush Presbyterian St Lukes Med Ctr, Rush Childrens Hosp, Dept Pediat, Chicago, IL 60612 USA
[5] Univ Penn, Childrens Hosp Philadelphia, Philadelphia, PA 19104 USA
[6] NHLBI, Natl Ctr Sleep Disorders Res, NIH, Bethesda, MD 20892 USA
[7] Boston Univ, Sch Med, Dept Pediat, Boston, MA 02118 USA
[8] Boston Univ, Sch Med, Dept Epidemiol & Biostat, Boston, MA 02118 USA
[9] Boston Univ, Sch Publ Hlth, Boston, MA 02118 USA
关键词
infant; polysomnography; transient EEG arousal; reliability; validity;
D O I
10.1097/00004691-200210000-00010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Infant arousal scoring based on the Atlas Task Force definition of transient EEG arousal was evaluated to determine (1) whether transient arousals can be identified and assessed reliably in infants and (2) whether arousal and no-arousal epochs scored previously by trained raters can be validated reliably by independent sleep experts. Phase I for inter-and intrarater reliability scoring was based on two datasets of sleep epochs selected randomly from nocturnal polysomnograms of healthy full-term, preterm, idiopathic apparent life-threatening event cases, and siblings of Sudden Infant Death Syndrome infants of 35 to 64 weeks postconceptional age. After training, test set I reliability was assessed and discrepancies identified. After retraining, test set 2 was scored by the same raters to determine interrater reliability. Later, three raters from the trained group rescored test set 2 to assess inter- and intrarater reliabilities. Interrater and intrarater reliability k's, With 95% confidence intervals, ranged from substantial to almost perfect levels of agreement. Interrater reliabilities for spontaneous arousals were initially moderate and then substantial. During the validation phase, 315 previously scored epochs were presented to four sleep experts to rate as containing arousal or no-arousal events. Interrater expert agreements were diverse and considered as noninterpretable. Concordance in sleep experts' agreements, based on identification of the previously sampled arousal and no-arousal epochs, was used as a secondary evaluative technique. Results showed agreement by two or more experts on 86% of the Collaborative Home Infant Monitoring Evaluation Study arousal scored events. Conversely, only 1% of the Collaborative Home Infant Monitoring Evaluation Study-scored no-arousal epochs were rated as an arousal. In summary, this study presents an empirically tested model with procedures and criteria for attaining improved reliability in transient EEG arousal assessments in infants using the modified Atlas Task Force standards. With training based on specific criteria, substantial inter- and intrarater agreement in identifying infant arousals was demonstrated. Corroborative validation results were too disparate for meaningful interpretation. Alternate evaluation based on concordance agreements supports reliance on infant EEG criteria for assessment. Results mandate additional confirmatory validation studies with specific training on infant EEG arousal assessment criteria.
引用
收藏
页码:469 / 483
页数:15
相关论文
共 50 条
  • [41] A Review of Normal Values of Infant Sleep Polysomnography
    Ng, Daniel K.
    Chan, Chung-Hong
    PEDIATRICS AND NEONATOLOGY, 2013, 54 (02): : 82 - 87
  • [42] Reliability and Validity of the Preterm Infant Feeding Survey: Instrument Development and Testing
    Dowling, Donna A.
    Madigan, Elizabeth
    Anthony, Mary K.
    Abou Elfettoh, Amel
    Graham, Gregory
    JOURNAL OF NURSING MEASUREMENT, 2009, 17 (03) : 171 - 182
  • [43] Validity and reliability of the Infant Feeding Attitude Scale in young people in Turkey
    Leyla Erdim
    Neriman Zengin
    Journal of Public Health, 2021, 29 : 1391 - 1399
  • [44] A validity and reliability study investigating the Turkish version of the Infant Colic Scale
    Cetinkaya, Bengu
    Basbakkal, Zumrut
    GASTROENTEROLOGY NURSING, 2007, 30 (02) : 84 - 90
  • [45] The Spanish version of the Alberta Infant Motor Scale: Validity and reliability analysis
    Morales-Monforte, Erica
    Bagur-Calafat, Caridad
    Suc-Lerin, Neus
    Fornaguera-Marti, Montserrat
    Cazorla-Sanchez, Engracia
    Girabent-Farres, Montserrat
    DEVELOPMENTAL NEUROREHABILITATION, 2017, 20 (02) : 76 - 82
  • [46] Preliminary estimation of the reliability and validity of the Infant Dental Anxiety Scale.
    Farah, RA
    Humphris, G
    Lee, GT
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A268 - A268
  • [47] Validity and reliability of the Infant Feeding Attitude Scale in young people in Turkey
    Erdim, Leyla
    Zengin, Neriman
    JOURNAL OF PUBLIC HEALTH-HEIDELBERG, 2021, 29 (06): : 1391 - 1399
  • [48] Concurrent validity and reliability of the Alberta Infant Motor Scale in premature infants
    Almeida, Kennea Martins
    Peixoto Dutra, Maria Virginia
    de Mello, Rosane Reis
    Rodrigues Reis, Ana Beatriz
    Martins, Priscila Silveira
    JORNAL DE PEDIATRIA, 2008, 84 (05) : 442 - 448
  • [49] ABNORMAL FORMS OF AROUSAL REACTIONS IN THE INFANT
    DREYFUSBRISAC, C
    BLANC, C
    KRAMARZ, P
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1956, 8 (04): : 726 - 726
  • [50] MATERNAL CONTRIBUTIONS TO INFANT REGULATION OF AROUSAL
    GABLE, S
    ISABELLA, RA
    INFANT BEHAVIOR & DEVELOPMENT, 1992, 15 (01): : 95 - 107