SEM based overlay measurement between Via patterns and buried M1 patterns using high voltage SEM

被引:6
|
作者
Hasumi, Kazuhisa [1 ]
Inoue, Osamu [1 ]
Okagawa, Yutaka [1 ]
Shao, Chuanyu [1 ]
Leray, Philippe [2 ]
Halder, Sandip [2 ]
Lorusso, Gian [2 ]
Jehoul, Christiane [2 ]
机构
[1] Hitachi High Technol, Tokyo, Japan
[2] Imec, Leuven, Belgium
关键词
High Voltage SEM; Overlay; See-through;
D O I
10.1117/12.2257848
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The miniaturization of semiconductors continues, importance of overlay measurement is increasing. We measured overlay with analysis SEM called Miracle Eye which can output ultrahigh acceleration voltage in 1998. Meanwhile, since 2006, we have been working on SEM based overlay measurement and developed overlay measurement function of the same layer using CD-SEM. Then, we evaluated overlay of the same layer pattern after etching. This time, in order to measure overlay after lithography, we evaluated the see-through overlay using high voltage SEM CV5000 released in October 2016. In collaboration between imec and Hitachi High-Technologies, we evaluated repeatability, TIS of SEM-OVL as well as correlation between SEM-OVL and Opt-OVL in the M1@ADI and V0@ADI process. Repeatability and TIS results are reasonable and SEM-OVL has good correlation with Opt-OVL. By overlay measurement using CV 5000, we got the following conclusions. (1) SEM_OVL results of both M1 and V0 at ADI show good correlation to OPT_OVL. (2) High voltage SEM can prove the measurement capability of a small pattern( Less than 1 similar to 2um) like device that can be placed in-die area. (3)"In-die SEM based overlay" shows possibility for high order control of scanner.
引用
收藏
页数:10
相关论文
共 27 条
  • [21] Using a measurement type-independent metric to compare patterns of determinants between patient-reported versus performance-based physical function in hemodialysis patients
    Liegl, Gregor
    Fischer, Felix H.
    Canaud, Bernard
    Woodward, Mark
    Barth, Claudia
    Davenport, Andrew
    Toeroek, Marietta
    Strippoli, Giovanni F. M.
    Hegbrant, Joergen
    Cromm, Krister
    Bots, Michiel L.
    Blankestijn, Peter J.
    Fischer, Kathrin I.
    Rose, Matthias
    QUALITY OF LIFE RESEARCH, 2024, 33 (11) : 2987 - 3001
  • [22] Measurement of aflatoxin M1 in powder and pasteurized milk samples by using a label-free electrochemical aptasensor based on platinum nanoparticles loaded on Fe-based metal-organic frameworks
    Jahangiri-Dehaghani, Fahime
    Zare, Hamid R.
    Shekari, Zahra
    FOOD CHEMISTRY, 2020, 310
  • [23] Sample-pretreatment-free based high sensitive determination of aflatoxin M1 in raw milk using a time-resolved fluorescent competitive immunochromatographic assay
    Tang, Xiaoqian
    Zhang, Zhaowei
    Li, Peiwu
    Zhang, Qi
    Jiang, Jun
    Wang, Du
    Lei, Jiawen
    RSC ADVANCES, 2015, 5 (01) : 558 - 564
  • [24] Clinical T1aN0M0 lung cancer: differences in clinicopathological patterns and oncological outcomes based on the findings on high-resolution computed tomography
    Sun, Ke
    You, Aijun
    Wang, Bin
    Song, Nan
    Wan, Ziwei
    Wu, Fengying
    Zhao, Wencheng
    Zhou, Fei
    Li, Wei
    EUROPEAN RADIOLOGY, 2021, 31 (10) : 7353 - 7362
  • [25] Clinical T1aN0M0 lung cancer: differences in clinicopathological patterns and oncological outcomes based on the findings on high-resolution computed tomography
    Ke Sun
    Aijun You
    Bin Wang
    Nan Song
    Ziwei Wan
    Fengying Wu
    Wencheng Zhao
    Fei Zhou
    Wei Li
    European Radiology, 2021, 31 : 7353 - 7362
  • [26] Comparing cerebral microembolisation patterns between high power short duration and pulsed field ablation techniques using artificial intelligence based robotic transcranial doppler monitoring
    Meszaros, H.
    Vamosi, P.
    Komlosi, F.
    Toth, P.
    Szegedi, N.
    Sallo, Z.
    Perge, P.
    Geller, L.
    Simon, Z. S.
    Nardai, S.
    Nagy, K., V
    EUROPEAN HEART JOURNAL, 2024, 45
  • [27] Investigations of the March 2006 African dust storm using ground-based column-integrated high spectral resolution infrared (8-13 μm) and visible aerosol optical thickness measurements: 1. Measurement procedures and results
    Thomas, M.
    Gautier, C.
    Ricchiazzi, P.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2009, 114