Cerebral blood flow monitoring using a novel laser Doppler flowmeter in asphyxiated infants

被引:1
|
作者
Ohashi, Atsushi [1 ]
Kuroyanagi, Yuichi [1 ]
Kitamura, Naoyuki [1 ]
Kinoshita, Yo [1 ]
Kaneko, Kazunari [1 ]
Yabuta, Keijiro [2 ]
机构
[1] Kansai Med Univ, Dept Pediat, Osaka 5731191, Japan
[2] Juntendo Univ, Sch Med, Tokyo 113, Japan
关键词
asphyxia; cerebral blood flow; laser Doppler flowmeter; stability index; HEMODYNAMICS; OXYGENATION;
D O I
10.1111/j.1442-200X.2009.02842.x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: The aim of the present study was to investigate the role of early changes in cerebral blood flow (CBF) predicting the severity of neurological outcome in asphyxiated infants. Method: Serial monitoring of CBF was performed using a newly developed laser Doppler flowmeter (LDF) in parallel with conventional hemodynamic monitoring, such as mean arterial blood pressure (mABP) or heart rate (HR) in 11 asphyxiated infants (five infants with neurological sequelae and six infants without sequelae) during the first 4 days of life. Psychomotor development was followed up to 20 months. Results: No differences in average CBF, mABP, average HR, or Apgar scores were found between infants with neurological sequelae and those without (P > 0.1). Significant difference was found only in average stability index during the first 48 h of life (SI48), defined as a coefficient of variation of CBF during the corresponding period (P = 0.04). An SI48 >= 0.24 had positive predictive value of 100% for neurological sequelae while that < 0.24 had a negative predictive value of 66.7%. Conclusion: SI48, an average stability index of CBF during the first 48 h of life, can be a useful index to predict neurological outcome in asphyxiated infants.
引用
收藏
页码:715 / 719
页数:5
相关论文
共 50 条
  • [31] TESTICULAR BLOOD-FLOW MEASURED WITH A LASER DOPPLER FLOWMETER - ACUTE EFFECTS OF CATECHOLAMINES
    DAMBER, JE
    LINDAHL, O
    SELSTAM, G
    TENLAND, T
    ACTA PHYSIOLOGICA SCANDINAVICA, 1982, 115 (02): : 209 - 215
  • [32] Ocular blood flow measured with scanning laser Doppler flowmeter in normals and glaucoma patients
    Nicolela, MT
    Hnik, P
    Drance, SM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 1282 - 1282
  • [33] Ocular blood flow measured with scanning laser Doppler flowmeter in normals and glaucoma patients
    Nicolela, MT
    Hnik, P
    Drance, SM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 131 - 131
  • [34] CEREBRAL BLOOD FLOW PATTERNS IN SEVERE HEAD TRAUMA USING TRANSCRANIAL DOPPLER MONITORING
    Mijangos-Mendez, Julio
    Aguirre-Avalos, Guadalupe
    Mendoza-Garibay, Ana
    Gonzalez-Navarro, Erika
    Corona-Jimenez, Federico
    Coronado-Magana, Hilario
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U91 - U91
  • [35] EARLY DETECTION OF LUNG REJECTION BY MEASUREMENT OF BRONCHIAL MUCOSAL BLOOD-FLOW USING LASER DOPPLER FLOWMETER
    TANABE, H
    YADA, I
    NAMIKAWA, S
    KUSAGAWA, M
    TRANSPLANTATION PROCEEDINGS, 1989, 21 (01) : 2590 - 2591
  • [36] Some Reasons to Build a New Laser Doppler Flowmeter to Monitor Microvascular Blood Flow
    Figueiras, E.
    Loureiro, V.
    Requicha Ferreira, L. F.
    Humeau, A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1865 - 1868
  • [37] EVALUATION OF AN INFRARED LASER-DOPPLER BLOOD FLOWMETER
    SHEPHERD, AP
    RIEDEL, GL
    KIEL, JW
    HAUMSCHILD, DJ
    MAXWELL, LC
    AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (06): : G832 - G839
  • [38] Evaluation of a new laser Doppler retinal blood flowmeter
    Feke, GT
    Ishiko, S
    McMeel, JW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S487 - S487
  • [39] Orthostatic response of cephalic blood flow using a mini laser Doppler blood flowmeter and hemodynamics of a new active standing test
    Goma, Masaki
    Kimura, Yoshinori
    Shimura, Hiroki
    Kaneshige, Masahiro
    Kobayashi, Tetsuro
    Kikuchi, Masashi
    Terada, Nobuyuki
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2015, 115 (10) : 2167 - 2176
  • [40] Orthostatic response of cephalic blood flow using a mini laser Doppler blood flowmeter and hemodynamics of a new active standing test
    Masaki Goma
    Yoshinori Kimura
    Hiroki Shimura
    Masahiro Kaneshige
    Tetsuro Kobayashi
    Masashi Kikuchi
    Nobuyuki Terada
    European Journal of Applied Physiology, 2015, 115 : 2167 - 2176