Methods of Measurement of LTCC Metallization Thickness

被引:0
|
作者
Khiang, Lee Soo [1 ]
Ahmad, Norhawati [1 ]
Isa, Muammar Mohamad [1 ]
Alias, Rosidah [1 ]
机构
[1] Univ Malaysia Perlis, Sch Microelect Engn, Jejawi 02060, Perlis, Malaysia
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Metallization provides electrical routing and serves as thermal via in LTCC (Low Temperature Cofired Ceramic) technology. High electrical and thermal conductivity is desirable. It is often achieved with the use of low electrical resistance materials, such as gold, silver and copper. The conductive paste made of these materials is expensive. Hence, the fabrication of LTCC has to be performance-wise and cost effective. The width, length and thickness of metallization are associated with the amount of conductor paste used. The thickness of metallization governs the functionality and performance of some components, such as resistor. In this paper, the physical attributes Of LTCC substrate and its metallization was studied. Due to the constraint brought by the physical attributes of LTCC samples, various methods had been carried out This paper also summarized the pros and cons of each method. The methods are limited to the equipment available.
引用
收藏
页码:280 / 286
页数:7
相关论文
共 50 条
  • [31] Methods and Modern Devices for Thickness Measurement of Metal Deposits.
    Guehring, W.H.
    Galvanotechnik, 1981, 72 (10): : 1059 - 1071
  • [32] COMPARATIVE STUDY ON METHODS FOR MEASUREMENT OF THICKNESS OF THIN-LAYERS
    SANTAS, JC
    ANALES DE FISICA, 1972, 68 (7-9): : 217 - 219
  • [33] Comparison of Two Different Methods in Central Corneal Thickness Measurement
    Yaycioglu, Rana Altan
    Pelit, Aysel
    Toygar, Okan
    Akova, Yonca Aydin
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2006, 36 (04): : 306 - 310
  • [34] Effect of load and thickness on the constrained sintering of LTCC substrates
    Cho, Jung-Hwan
    Yeo, Dong-Hun
    Shin, Hyo-Soon
    Hong, Youn-Woo
    Nahm, Sahn
    JOURNAL OF CERAMIC PROCESSING RESEARCH, 2011, 12 (05): : 500 - 503
  • [35] Comparing Full Lateral Metallization and Reference Plane Stitching in LTCC Boards for Satellite Applications
    Trave, A.
    Di Pasquale, A.
    Antonini, G.
    Orlandi, A.
    2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1-3, 2008, : 6 - 11
  • [37] Investigation methods of the layer deposited by metallization
    Chiș, Marius
    Achimaș, Gheorghe
    Trif, Adrian
    Campbell, Ian
    Academic Journal of Manufacturing Engineering, 2019, 17 (01): : 57 - 62
  • [38] Measurement of melanoma thickness - comparison of two methods: Ultrasound versus morphology
    Kaikaris, Vygintas
    Samsanavicius, Donatas
    Maslauskas, Kestutis
    Rimdeika, Rytis
    Valiukeviciene, Skaidra
    Makstiene, Jurgita
    Pundzius, Juozas
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2011, 64 (06): : 796 - 802
  • [39] Corneal thickness measurement by confocal microscopy, ultrasound, and scanning slit methods
    McLaren, JW
    Nau, CB
    Erie, JC
    Bourne, WM
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (06) : 1011 - 1020
  • [40] Comparative study on the specimen thickness measurement using EELS and CBED methods
    Heo Y.-U.
    Appl. Microsc., 2020, 1 (1):