A novel algorithm for automatic diagnosis of sleep apnea from airflow and oximetry signals

被引:7
|
作者
Uddin, M. B. [1 ,2 ]
Chow, C. M. [3 ,4 ]
Ling, S. H. [1 ,2 ]
Su, S. W. [1 ,2 ]
机构
[1] Univ Technol Sydney, Fac Engn & Informat Technol, Sch Biomed Engn, Sydney, NSW, Australia
[2] Univ Technol Sydney, Ctr Hlth Technol, Sydney, NSW, Australia
[3] Univ Sydney, Fac Med & Hlth, Sydney Sch Hlth Sci, Sydney, NSW, Australia
[4] Univ Sydney, Charles Perkins Ctr, Sleep Res Grp, Sydney, NSW, Australia
关键词
airflow envelope tracking; digitization; time lag adjustment; estimated total sleep time; limits of agreement; HYPOPNEA EVENTS; MONITOR; VALIDATION; UPDATE; RULE;
D O I
10.1088/1361-6579/abd238
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. Sleep apnea significantly decreases the quality of life. The apnea hypopnea index (AHI) is the main indicator for sleep apnea diagnosis. This study explored a novel automatic algorithm to diagnose sleep apnea from nasal airflow (AF) and pulse oximetry (SpO(2)) signals. Approach. Of the 988 polysomnography (PSG) records from the sleep heart health study (SHHS), 45 were randomly selected for the development of an algorithm and the remainder for validation (n = 943). The algorithm detects apnea events by a digitization process, following the determination of the peak excursion (peak-to-trough amplitude) from AF envelope. Hypopnea events were determined from the AF envelope and oxygen desaturation with correction to time lag in SpO(2). Total sleep time (TST) was estimated from an optimized percentage of artefact-free total recording time. AHI was estimated from the number of detected events divided by the estimated TST. The estimated AHI was compared to the scored SHHS data for performance evaluation. Main results. The validation showed good agreement between the estimated and scored AHI (intraclass correlation coefficient of 0.95 and mean 95% limits of agreement of -1.6 12.5 events h(-1)). The diagnostic accuracies were found: 90.7%, 91%, and 96.7% for AHI cut-off >= 5, >= 15, and >= 30 respectively. Significance. The new algorithm is accurate over other existing methods for the automatic diagnosis of sleep apnea. It is applicable to any portable sleep screeners especially for the home diagnosis of sleep apnea.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] A classification algorithm based on spectral features from nocturnal oximetry and support vector machines to assist in the diagnosis of obstructive sleep apnea
    Victor Marcos, J.
    Hornero, Roberto
    Alvarez, Daniel
    Del Campo, Felix
    Zamarron, Carlos
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5547 - +
  • [22] Accuracy of oximetry with thermistor (OxiFlow) for diagnosis of obstructive sleep apnea and hypopnea
    Baltzan, MA
    Verschelden, P
    Al-Jahdali, H
    Olha, AE
    Kimoff, RJ
    [J]. SLEEP, 2000, 23 (01) : 61 - 69
  • [23] Diagnosis of obstructive sleep apnea syndrome using overnight oximetry measurement
    Youn, T.
    Yoon, J.
    [J]. SLEEP, 2008, 31 : A189 - A189
  • [24] Nocturnal Oximetry for the Diagnosis of Obstructive Sleep Apnea Syndrome (OSAS) in Infants
    Moudaki, A.
    Polytarchou, A.
    Koltsida, G.
    Kanaka-Gantenbein, C.
    Kaditis, A.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [25] Automatic discrimination between obstructive and central sleep apnea using pulse oximetry
    Holleboom, Minke
    Fabius, Timon
    Eijsvogel, Michiel
    Van der Palen, Job
    De Jongh, Frans
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [26] Automatic diagnosis of sleep apnea from biomedical signals using artificial intelligence techniques: Methods, challenges, and future works
    Moridian, Parisa
    Shoeibi, Afshin
    Khodatars, Marjane
    Jafari, Mahboobeh
    Pachori, Ram Bilas
    Khadem, Ali
    Alizadehsani, Roohallah
    Ling, Sai Ho
    [J]. WILEY INTERDISCIPLINARY REVIEWS-DATA MINING AND KNOWLEDGE DISCOVERY, 2022, 12 (06)
  • [27] Usefulness of discrete wavelet transform in the analysis of oximetry signals to assist in childhood sleep apnea-hypopnea syndrome diagnosis
    Vaquerizo-Villar, Fernando
    Alvarez, Daniel
    Gutierrez-Tobal, Gonzalo C.
    Barroso-Garcia, Veronica
    Kheirandish-Gozal, Leila
    Crespo, Andrea
    del Campo, Felix
    Gozal, David
    Hornero, Roberto
    [J]. 2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 3753 - 3756
  • [28] Statistical and Nonlinear Analysis of Oximetry from Respiratory Polygraphy to Assist in the Diagnosis of Sleep Apnea in Children
    Alvarez, Daniel
    Gutierrez-Tobal, Gonzalo C.
    Alonso, Maria L.
    Teran, Joaqui
    del Campo, Felix
    Hornero, Roberto
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1860 - 1863
  • [29] Bispectral analysis of overnight airflow to improve the pediatric sleep apnea diagnosis
    Barroso-Garcia, Veronica
    Gutierrez-Tobal, Gonzalo C.
    Kheirandish-Gozal, Leila
    Vaquerizo-Villar, Fernando
    Alvarez, Daniel
    del Campo, Felix
    Gozal, David
    Hornero, Roberto
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 129
  • [30] Automatic Detection of Obstructive Sleep Apnea Using Speech Signals
    Goldshtein, Evgenia
    Tarasiuk, Ariel
    Zigel, Yaniv
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (05) : 1373 - 1382