Influence of Inverter-Interfaced Renewable Energy Generators on Directional Relay and an Improved Scheme

被引:99
|
作者
Jia, Ke [1 ]
Yang, Zhe [1 ]
Fang, Yu [1 ]
Bi, Tianshu [1 ]
Sumner, Mark [2 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternat Elect Power Syst Renewable, Beijing 102206, Peoples R China
[2] Univ Nottingham, Nottingham NG7 2RD, England
基金
中国国家自然科学基金;
关键词
Angular characteristics; directional relay; high-frequency impedance; renewable power sources; sequence super-imposed impedance; GRID-CONNECTED INVERTER; WIND POWER; PROTECTION CHALLENGES; DISTANCE PROTECTION; LCL FILTER; SYSTEMS; COORDINATION; INTEGRATION; RESOURCES; LINES;
D O I
10.1109/TPEL.2019.2904715
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Renewable energy sources are typically interfaced to the grid using power electronics, which can cause their fault current characteristics to display significant low-frequency harmonics and unbalanced sequence impedances. Such current characteristics can lead to the operation failure of fault-component-based directional relays. To demonstrate the influence of inverter-interfaced renewable energy generators (IIREGs) on directional relays in detail, analytical expressions for the IIREG equivalent positive- and negative-sequence superimposed impedances are derived in this paper. Considering various factors, the angular characteristics of the sequence superimposed impedances are investigated. Based on these attributes, it can be concluded that fault-component-based directional relays may be unable to operate in some circumstances. A novel high-frequency impedance-based protection scheme is proposed to manage the adaptability problem by determining the fault direction due to a stable impedance angle. The theoretical analysis and the proposed scheme are tested and verified through real time digital simulation and field testing data.
引用
收藏
页码:11843 / 11855
页数:13
相关论文
共 50 条
  • [31] Impact of Inverter-Interfaced Renewable Generation on Transient Stability at Varying Levels of Penetration
    Liu, Zhao
    Zhang, Ziang
    Lin, Yashen
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 4027 - 4032
  • [32] Fault Approximation Tool for Grid-Connected Inverter-Interfaced Distributed Generators
    Kennedy, Joel
    Ciufo, Phil
    Agalgaonkar, Ashish
    2014 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2014,
  • [33] Fault Models of Inverter-Interfaced Distributed Generators Within a Low-Voltage Microgrid
    Guo, Wen-Ming
    Mu, Long-Hua
    Zhang, Xin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (01) : 453 - 461
  • [34] Pilot protection scheme for distribution network considering low voltage ride-through of inverter-interfaced distributed generators
    Zhao, Fengxian
    Meng, Zhen
    Li, Yongqin
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 15 (11) : 1613 - 1621
  • [35] Fault Models of Inverter-Interfaced Distributed Generators: Experimental Verification and Application to Fault Analysis
    Plet, Cornelis A.
    Brucoli, Maria
    McDonald, John D. F.
    Green, Timothy C.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [36] Ground Fault Overvoltage With Inverter-Interfaced Distributed Energy Resources
    Ropp, Michael
    Hoke, Anderson
    Chakraborty, Sudipta
    Schutz, Dustin
    Mouw, Chris
    Nelson, Austin
    McCarty, Michael
    Wang, Trudie
    Sorenson, Adam
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (02) : 890 - 899
  • [37] An Improved Pilot Protection for Distribution Network With Inverter-Interfaced Distributed Generations
    Han, Bowen
    Wang, Gang
    Li, Haifeng
    Zeng, Dehui
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 2555 - 2559
  • [38] Robust Controller Design for Inverter-Interfaced Distributed Generators Considering Islanded Operation of a Microgrid
    Chung, Il-Yop
    Liu, Wenxin
    Leng, Siyu
    Cartes, David A.
    Collins, Emmanuel G., Jr.
    2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 958 - 965
  • [39] A New Approach to Transmission Line Pilot Protection in the Presence of Inverter-Interfaced Distributed Generators
    Chakeri, Vahid
    Seyedi, Heresh
    Tarafdar Hagh, Mehrdad
    IEEE SYSTEMS JOURNAL, 2021, 15 (04): : 5383 - 5392
  • [40] Pilot protection based on current amplitude ratio for teed line in inverter-interfaced renewable energy power plants
    Jia K.
    Yang Z.
    Zhu Z.
    Zheng L.
    Bi T.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (12): : 82 - 88