Corneal Parameters in Healthy Subjects Assessed by Corvis ST

被引:22
|
作者
Salouti, Ramin [1 ,2 ]
Bagheri, Mansoureh [1 ]
Shamsi, Anis [1 ]
Zamani, Mohammad [2 ]
Ghoreyshi, Maryam [3 ]
Nowroozzadeh, M. Hossein [1 ]
机构
[1] Shiraz Univ Med Sci, Poostchi Ophthalmol Res Ctr, Sch Med, Dept Ophthalmol, Shiraz, Iran
[2] Salouti Eye Clin, Salouti Cornea Res Ctr, Shiraz, Iran
[3] Shiraz Univ Med Sci, Hlth Policy Res Ctr, Shiraz, Iran
关键词
Central Corneal Thickness; Corneal Biomechanics; Corvis ST; Intraocular Pressure; INTRAOCULAR-PRESSURE; BIOMECHANICAL METRICS; NONCONTACT; THICKNESS; TONOMETER;
D O I
10.18502/jovr.v15i1.5936
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate corneal biomechanics using Corvis ST in healthy eyes from Iranian keratorefractive surgery candidates. Methods: In this prospective consecutive observational case series, the intraocular pressure (IOP), central corneal thickness (CCT), and biomechanical properties of 1,304 eyes from 652 patients were evaluated using Corvis ST. Keratometric readings and manifest refraction were also recorded. Results: The mean (+/- SD) age of participants was 28 +/- 5 years, and 31.7% were male. The mean spherical equivalent refraction was -3.50 +/- 1.57 diopters (D), the mean IOP was 16.8 +/- 2.9 mmHg, and the mean CCT was 531 +/- 31.. m for the right eye. The respective means (+/- SD) corneal biomechanical parameters of the right eye were as follows: first applanation time: 7.36 +/- 0.39 milliseconds (ms); first applanation length: 1.82 +/- 0.22 mm; velocity in: 0.12 +/- 0.04 m/s; second applanation time: 20.13 +/- 0.48 ms; second applanation length: 1.34 +/- 0.55 mm; velocity out: -0.67 +/- 0.17 m/s; total time: 16.84 +/- 0.64 ms; deformation amplitude: 1.05 +/- 0.10 mm; peak distance: 4.60 +/- 1.01 mm; and concave radius of curvature: 7.35 +/- 1.39 mm. In the linear regression analysis, IOP exhibited a statistically significant association with the first and second applanation times, total time, velocity in, peak distance, deformation amplitude, and concave radius of curvature. Conclusion: Our study results can be used as a reference for the interpretation of Corvis ST parameters in healthy refractive surgery candidates in the Iranian population. Our results confirmed that IOP is a major determinant of Corvis parameters.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 50 条
  • [31] Measurement of corneal biomechanical properties in diabetes mellitus using the Corvis ST
    Ohn, Kyoung
    Noh, Young Ho
    Moon, Jung Il
    Jung, Younhea
    MEDICINE, 2022, 101 (36) : E30248
  • [32] Novel Method of Measuring Corneal Viscoelasticity Using the Corvis ST Tonometer
    Boszczyk, Agnieszka
    Kasprzak, Henryk
    Przezdziecka-Dolyk, Joanna
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (01)
  • [33] Determination of Corneal Nonlinear Viscoelastic Biomechanical Properties using Corvis ST
    Zhalgas, Aidana
    Ko, Match W. L.
    Kim, Jong R.
    2019 IEEE 19TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2019, : 634 - 637
  • [34] A comparison of the corneal biomechanics in pseudoexfoliation glaucoma, primary open-angle glaucoma and healthy controls using Corvis ST
    Pradhan, Zia Sultan
    Deshmukh, Sujit
    Dixit, Shivani
    Sreenivasaiah, Shruthi
    Shroff, Sujani
    Devi, Sathi
    Webers, Carroll A. B.
    Rao, Harsha Laxmana
    PLOS ONE, 2020, 15 (10):
  • [35] Ocular Biomechanical Metrics by CorVis ST in Healthy Brazilian Patients
    Valbon, Bruno Freitas
    Ambrosio, Renato, Jr.
    Fontes, Bruno Machado
    Luz, Allan
    Roberts, Cynthia J.
    Alves, Milton Ruiz
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (07) : 468 - 473
  • [36] Evaluation of changes in corneal biomechanics after orthokeratology using Corvis ST
    Zhang, PeiPei
    Wu, JinFang
    Jiang, Jun
    Zhang, XinYu
    Ran, ZiYing
    Jiang, Fan
    Zheng, XiaoBo
    Wang, JunJie
    Elsheikh, Ahmed
    Bao, FangJun
    CONTACT LENS & ANTERIOR EYE, 2024, 47 (01):
  • [37] Relationship of corneal hysteresis and optic nerve parameters in healthy myopic subjects
    Kunliang Qiu
    Xuehui Lu
    Riping Zhang
    Geng Wang
    Mingzhi Zhang
    Scientific Reports, 7
  • [38] Relationship of corneal hysteresis and optic nerve parameters in healthy myopic subjects
    Qiu, Kunliang
    Zhang, Riping
    Wang, Geng
    Zhang, Mingzhi
    SCIENTIFIC REPORTS, 2017, 7
  • [39] CORNEAL BIOMECHANICS: EVALUATING PURE CORNEAL DEFORMATION IN KERATOCONIC AND NORMAL EYES USING THE CORVIS ST
    Vellara, Hans
    Ali, Noor
    Patel, Dipika
    McGhee, Charles
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 : 69 - 69
  • [40] Correlations among Corneal Biomechanical Parameters, Stiffness, and Thickness Measured Using Corvis ST and Pentacam in Patients with Ocular Hypertension
    Liu, Qian
    Pang, Chenjiu
    Liu, Changgeng
    Cheng, Wenjun
    Ming, Shuai
    Du, Wenwen
    Feng, Xiaomei
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022