Biodegradable cement augmentation of gamma nail osteosynthesis reduces migration in pertrochanteric fractures, a biomechanical in vitro study

被引:4
|
作者
Bungartz, Matthias [1 ]
Matziolis, Georg [1 ]
Layher, Frank [1 ]
Horbert, Victoria [2 ]
Maslaris, Alexander [1 ]
Brinkmann, Olaf [1 ]
机构
[1] Chair Jena Univ Hosp, Dept Orthopaed, Waldkliniken Eisenberg, Klosterlausnitzer Str 81, D-07607 Eisenberg, Germany
[2] Jena Univ Hosp, Expt Rheumatol Unit, Jena, Germany
关键词
Biodegradable cement augmentation; Pertrochanteric fracture; Osteoporosis; Cut-out; Fragment migration; BONE-CEMENT; EX-VIVO; MODEL; SCREW; FIXATION; IMPLANTS;
D O I
10.1016/j.clinbiomech.2021.105327
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Cut-out of gamma nail often results from poor primary bone stability, suboptimal reduction (varus) and excentric placement of the head element which may lead to "instability" and frequently requires revision. Various studies have shown that augmentation with polymethylmethacrylate cement increases the primary stability of osteosynthesis. However, it has not yet been widely used in fracture treatment due to certain disadvantages, e.g., the lack of osteointegration, the formation of an interface membrane or the presence of toxic monomers. Few studies show that biodegradable bone cements increase the stability of osteosynthesis in different anatomical regions and therefore could be an alternative to polymethylmethacrylate cement in the treatment of pertrochanteric fractures. Methods: Two biomechanical situations were simulated using 24 Sawbones (simple and multifragmentary pertrochanteric fractures; AO-classification 31-A1 and 31-A2. Both groups were stabilized using the Gamma3 (R) nailing system with and without biodegradable bone cement. Sawbones underwent the same cyclic loading test, simulating 10.000 gait cycles loading the bones with three times body weight. Migration was determined by comparing computed tomography scans recorded before and after the mechanical testing. The three-dimensional migration of the lag screw was calculated, and the rotation of the head around the longitudinal axis was determined. Findings: Biodegradable cement reduced migration by approximately 35% in 31-A1 fractures (25.4% in 31-A2 fractures) and the rotation of the head around the lag screw by approximately 37% in 31-A1 fractures (17.8%, 31-A2). Interpretation: Use of biodegradable bone cement improved the primary stability of gamma nail osteosynthesis in the biomechanical model.
引用
收藏
页数:6
相关论文
共 39 条
  • [31] Comparison of fibula strut and calcium phosphate cement augmentation of the medial buttress in 2-part proximal humerus fractures reconstruction: a biomechanical study
    Dmitry Pokhvashchev
    Riley Knox
    Matthew Herring
    Safa Herfat
    Meir Tibrin Marmor
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 67 - 72
  • [32] Comparison of fibula strut and calcium phosphate cement augmentation of the medial buttress in 2-part proximal humerus fractures reconstruction: a biomechanical study
    Pokhvashchev, Dmitry
    Knox, Riley
    Matthew, Herring
    Safa, Herfat
    Meir, Marmor T.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (01): : 67 - 72
  • [33] Correction to: Comparison of fibula strut and calcium phosphate cement augmentation of the medial buttress in 2-part proximal humerus fractures reconstruction: a biomechanical study
    Dmitry Pokhvashchev
    Riley Knox
    Matthew Herring
    Safa Herfat
    Meir Tibrin Marmor
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 73 - 73
  • [34] Comparison of Long Segmental Dorsal Stabilization with Complete Versus Restricted Pedicle Screw Cement Augmentation in Unstable Osteoporotic Midthoracic Vertebral Body Fractures: A Biomechanical Study
    Spiegl, Ulrich J.
    Weidling, Martin
    Schleifenbaum, Stefan
    Reinhardt, Martin
    Heyde, Christoph-E.
    WORLD NEUROSURGERY, 2020, 143 : E541 - E549
  • [35] Novel Semi-Cannulated Screw Enhanced Bone Cement Augmentation and Pullout Strength in Posterior Cervical Lateral Mass Screw Fixations: An In Vitro Biomechanical and Morphological Study
    Huang, Canyang
    Chen, Weidong
    Huang, Zhiping
    Hu, Xiuhua
    Zheng, Minghui
    Huang, Haihong
    Zhu, Qingan
    Qu, Dongbin
    ORTHOPAEDIC SURGERY, 2023, 15 (11) : 2927 - 2936
  • [36] Surgical Treatment of Osteoporotic Thoracolumbar Compressive Fractures with Open Vertebral Cement Augmentation of Expandable Pedicle Screw Fixation: A Biomechanical Study and a 2-Year Follow-up of 20 Patients
    Wu, Zi-xiang
    Gao, Ming-xuan
    Sang, Hong-xun
    Ma, Zhen-sheng
    Cui, Geng
    Zhang, Yang
    Lei, Wei
    JOURNAL OF SURGICAL RESEARCH, 2012, 173 (01) : 91 - 98
  • [37] Migration of the Lag Screw after Intramedullary Treatment of AO/OTA 31.A2.1-3 Pertrochanteric Fractures Does Not Result in Higher Incidence of Cut-Outs, Regardless of Which Implant Was Used: A Comparison of Gamma Nail with and without U-Blade (RC) Lag Screw and Proximal Femur Nail Antirotation (PFNA)
    Lang, Nikolaus Wilhelm
    Breuer, Robert
    Beiglboeck, Hannes
    Munteanu, Alexandru
    Hajdu, Stefan
    Windhager, Reinhard
    Widhalm, Harald Kurt
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (05)
  • [38] Comparison of fibula strut and calcium phosphate cement augmentation of the medial buttress in 2-part proximal humerus fractures reconstruction: a biomechanical study (Nov, 10.1007/s00590-021-03147-1, 2021)
    Pokhvashchev, Dmitry
    Knox, Riley
    Herring, Matthew
    Herfat, Safa
    Marmor, Meir Tibrin
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (01): : 73 - 73
  • [39] With regard to: "Subtrochanteric fractures - Comparative study of the gamma nail and angular osteosynthesis with external cortical support" - J.C. Lahoud, A. Asselineau, S. Salengro, V. Molina, M. Bombart (Villeneuve-Saint-Georges) (Revue de Chirurgie Orthopedique, 1997, 83, 335-342).
    Lemaire, R
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1998, 84 (03): : 293 - 293