Quinoline-derived fluorescent probes for the discrimination of Cys from Hcys/GSH and bioimaging in living cells

被引:30
|
作者
Wu, Qingqing [1 ,2 ]
Mao, Mao [3 ]
Liang, Wenlang [1 ]
Stadler, Florian J. [1 ]
机构
[1] Shenzhen Univ, Guangdong Res Ctr Interfacial Engn Funct Mat, Coll Mat Sci & Engn,Shenzhen Key Lab Polymer Sci, Nanshan Dist Key Lab Biopolymers & Safety Evaluat, Shenzhen 518060, Peoples R China
[2] Shenzhen Univ, Coll Optoelect Engn, Minist Educ & Guangdong Prov, Key Lab Optoelect Devices & Syst, Shenzhen 518060, Peoples R China
[3] Nanjing Univ Informat Sci & Technol, Sch Atmospher Phys, Nanjing 210044, Jiangsu, Peoples R China
关键词
Quinoline; Ratiometric; Fluorescence; Probe; Thiol; Cell imaging; LARGE STOKES SHIFT; LARGE EMISSION SHIFT; TURN-ON PROBE; SELECTIVE DETECTION; THIOL PROBE; DISTINGUISHING CYSTEINE; BLOOD-PLASMA; LIVE CELLS; IN-VIVO; HOMOCYSTEINE;
D O I
10.1016/j.talanta.2018.04.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Development of thiol-specific fluorescent probes with selectivity in different thiol compounds is more practical and significant than those without that capacity. In this work, a new quinoline-derived fluorophore, hydroxyl substituted quinoline-benzo[d]oxazole 6 with high fluorescence quantum yield is synthesized and esterified with acrylic acid to afford two fluorescent probes, BQA-1 and BQA-2 for selectively discriminating Cys from Hcys/GSH based on conjugate addition-cyclization mechanism. BQA-1 exhibits a large ratiometric fluorescence response toward Cys in aqueous pH 7.4 solution with big emission peak-shifting from 383 nets to 518 nm, over 130 nm. The detection limit is determined to be as low as 0.59 mu M. In contrast to BQA-1, BQA-2 whose acrylic ester moiety is further modified with pyridine group, displays a turn-on fluorescence response to Cys with detection limit of 0.98 mu M. Both BQA-1 and BQA-2 have relatively weak response to another two biothiols, Hcys and GSH and nearly no response to other nucleophiles. Furthermore, the potential application for the detection of biothiols in living cells has been demonstrated by cell imaging experiment.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 50 条
  • [21] A novel strategy for rhodamine B-based fluorescent probes with a selective glutathione response for bioimaging in living cells
    Li, Zhipeng
    Xiong, Wei
    He, Xiaojun
    Qi, Xiaoliang
    Ding, Feng
    Shen, Jianliang
    ANALYST, 2020, 145 (12) : 4239 - 4244
  • [22] Indolenine-Based Derivatives as Customizable Two-Photon Fluorescent Probes for pH Bioimaging in Living Cells
    Benitez-Martin, Carlos
    Guadix, Juan A.
    Pearson, John R.
    Najera, Francisco
    Perez-Pomares, Jose M.
    Perez-Inestrosa, Ezequiel
    ACS SENSORS, 2020, 5 (04): : 1068 - 1074
  • [23] A simple amide fluorescent sensor based on quinoline for selective and sensitive recognition of zinc(II) ions and bioimaging in living cells
    Liu, Haiyang
    Tan, Ying
    Dai, Qiuzi
    Liang, Hongda
    Song, Jun
    Qu, Junle
    Wong, Wai-Yeung
    DYES AND PIGMENTS, 2018, 158 : 312 - 318
  • [24] Rational design of cascade reaction-assisted trinal-site fluorescent probe for simultaneous discrimination of Cys, Hcy, GSH, and H 2 S in living cells and zebrafish
    Wang, Qian
    Zhang, Wenting
    Cai, Mingzhe
    Ma, Yafei
    Yu, Ajuan
    Chen, Sheng
    Zhang, Shusheng
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 418
  • [25] An AIE-active fluorescent probe with near-infrared (NIR) emission for selectively monitoring and bioimaging Cys in living cells
    Zhang, Zhen
    Zhao, Weijun
    Chen, Yun
    Wei, Sheng-Hao
    Zhu, Fei
    Zhu, Xu-Zhong
    Wang, Cheng-Yun
    TETRAHEDRON, 2023, 140
  • [26] Fluorescent Probes for Lipid Rafts: From Model Membranes to Living Cells
    Klymchenko, Andrey S.
    Kreder, Remy
    CHEMISTRY & BIOLOGY, 2014, 21 (01): : 97 - 113
  • [27] Adjusting the Linear Range of Au-MOF Fluorescent Probes for Real Time Analyzing Intracellular GSH in Living Cells
    Du, Tianyu
    Zhang, Hang
    Ruan, Jun
    Jiang, Hui
    Chen, Hong-Yuan
    Wang, Xuemei
    ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (15) : 12417 - 12423
  • [28] A novel near-infrared styryl-BODIPY fluorescent probe for discrimination of GSH and its application in living cells
    Wang, Chengjun
    Xia, Xiang
    Luo, Jirong
    Qian, Ying
    DYES AND PIGMENTS, 2018, 152 : 85 - 92
  • [29] Multi-signal fluorescent probe for simultaneous differentiation and imaging of Hg2+, Cys, Hcy, and GSH in living cells and zebrafish
    Li, Yang
    Li, Jing
    Yu, Ting
    Cai, Hongyi
    Zhang, Youyu
    Li, Haitao
    Zhou, Huijun
    Yin, Peng
    JOURNAL OF HAZARDOUS MATERIALS, 2025, 488
  • [30] Quantitative Detection of Zn2+ in Infant Formula and Living Cells Using Quinoline-Based Fluorescent Probes
    Lu, Wen
    Chen, Jichao
    Tang, Jiongya
    Chen, Yutian
    Ma, Yingying
    Sang, Wuhan
    Feng, Sicheng
    Yang, Shilong
    Wang, Yanqin
    Li, Xu
    FOOD ANALYTICAL METHODS, 2025, 18 (02) : 190 - 201