A study of pulsating flow in automotive catalyst systems

被引:0
|
作者
Benjamin, SF [1 ]
Roberts, CA [1 ]
Wollin, J [1 ]
机构
[1] Coventry Univ, Sch Engn, Coventry CV1 5FB, W Midlands, England
关键词
Automobiles - Catalytic converters - Diffusers (fluid) - Pressure drop - Reynolds number - Steady flow;
D O I
10.1007/s00348-002-0481-0
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Conversion efficiency, durability and pressure drop of automotive exhaust catalysts are dependent on the flow distribution within the substrate. This study examines the effect of pulsating flow on the flow distribution within these systems. The flow distribution was measured for a range of flow rates at pulsation frequencies of 16, 32, 64 and 100 Hz. It was shown that the flow uniformity at 16 Hz was similar to the steady equivalent whereas improved uniformity was seen at the higher frequencies resulting in a reduced pressure drop. It was further found that flow maldistribution under pulsating conditions was less sensitive to increases in flow rate compared to steady-state flow. Downstream of the monolith strong pulses were observed although the pulse shapes changed across the substrate diameter. Flow maldistribution correlated well with a non-dimensional parameter derived from the inlet flow velocity, pulsation frequency and diffuser length.
引用
收藏
页码:629 / 639
页数:11
相关论文
共 50 条
  • [41] Experimental study of heat transfer in pulsating turbulent flow in a pipe
    Elshafei, Elsayed A. M.
    Mohamed, M. Safwat
    Mansour, H.
    Sakr, M.
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2008, 29 (04) : 1029 - 1038
  • [42] Study on Circulation Flow in Closed Loop Pulsating Heat Pipe
    Kang, Shung-Wen
    Chan, Chien-Hsuan
    Hsiao, Pai-Chun
    JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS, 2022, 43 (02): : 79 - 86
  • [43] Study on Circulation Flow in Closed Loop Pulsating Heat Pipe
    Kang, Shung-Wen
    Chan, Chien-Hsuan
    Hsiao, Pai-Chun
    Journal of the Chinese Society of Mechanical Engineers, Transactions of the Chinese Institute of Engineers, Series C/Chung-Kuo Chi Hsueh Kung Ch'eng Hsuebo Pao, 2022, 43 (02): : 79 - 86
  • [44] Numerical study of pulsating flow through a tapered artery with stenosis
    Liu, GT
    Wang, XJ
    Ai, BQ
    Liu, LG
    CHINESE JOURNAL OF PHYSICS, 2004, 42 (04) : 401 - 409
  • [45] Study on the pulsating flow of a worm-like micellar solution
    Emilio Herrera, E.
    Calderas, F.
    Chavez, A. E.
    Manero, O.
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2010, 165 (3-4) : 174 - 183
  • [46] Analytical study of pulsating laminar flow field in rectangular channel
    Liu, Yu-Sheng
    Tan, Si-Chao
    Gao, Pu-Zhen
    Yuan, Qi-Bin
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2012, 46 (11): : 1318 - 1323
  • [47] Study of High-Frequency Pulsating Flow Control Valves
    Zhang, Dongdong
    Wu, Yunchen
    Zhu, Kuankuan
    Shi, Ruiyi
    Ruan, Jian
    Ding, Chuan
    APPLIED SCIENCES-BASEL, 2024, 14 (22):
  • [48] Study on the measurement error of differential pressure flowmeter in pulsating flow
    Zhu, Yun
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2006, 27 (08): : 894 - 897
  • [49] Numerical study of heat transfer in pulsating turbulent air flow
    Elshafei, E. A. M.
    Mohamed, M. Safwat
    Mansour, H.
    Sakr, M.
    2007 INTERNATIONAL CONFERENCE ON THERMAL ISSUES IN EMERGINGTECHNOLOGIES - THEORY AND APPLICATIONS, 2007, : 60 - +
  • [50] Study on Phase Difference and Transient Flow Field in Rod Bundle under Pulsating Flow
    Li X.
    Qi P.
    Tan S.
    Hao S.
    Mi Z.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (08): : 1402 - 1409