Calibration transfer across near infrared spectrometers for measuring hematocrit in the blood of grazing cattle

被引:10
|
作者
Luo, Xuan [1 ]
Ikehata, Akifumi [1 ]
Sashida, Kunio [2 ]
Piao, Shanji [2 ]
Okura, Tsutomu [2 ]
Terada, Yutaka [3 ]
机构
[1] NARO, Natl Food Res Inst, 2-1-12 Kannondai, Tsukuba, Ibaraki 3058642, Japan
[2] Soma Opt Ltd, Tokyo, Japan
[3] NARO, Natl Inst Anim Hlth, 3-1-5 Kannondai, Tsukuba, Ibaraki, Japan
关键词
Anemia; hematocrit; calibration transfer; robust model; wavelength selection; skew and bias correction; piecewise direct standardization; MULTIVARIATE INSTRUMENT STANDARDIZATION; SOLUBLE SOLIDS CONTENT; PARTIAL LEAST-SQUARES; WAVELENGTH SELECTION; REGRESSION; SPECTROSCOPY; REFLECTANCE; IMPROVEMENT; SPECTRA; ARRAY;
D O I
10.1177/0967033516686658
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
For fast diagnosis of anemia for cattle farmed on pastures, portable short wavelength near infrared spectrometer instrument was built, and the feasibility of estimating hematocrit by partial least squares regression modeling was validated in our previous work. As a follow-up, the present study reports calibration transfer from one master instrument to two slave instruments. Different approaches, i.e. making robust models, skew and bias correction, and piecewise direct standardization, were compared. Our results show that making more use of simple models based on appropriate preprocessing, number of latent variables, and wavelength selection, can sometimes be as effective as applying standardization algorithm (e.g. piecewise direct standardization) when tackling the spectral differences between instruments. The importance of a robust model during the process of calibration transfer is shown. Application of standardization such as piecewise direct standardization could be risky when the model to be transferred is not robust enough.
引用
收藏
页码:15 / 25
页数:11
相关论文
共 50 条
  • [21] Calibration of visible and near infrared spectrums for measuring freshness of vegetables
    Abdullah, Faisal
    Jafri, M. Z. Mat
    Jaafar, M. S.
    Wong, C. J.
    THERMOSENSE XXX, 2008, 6939 : U93 - U98
  • [22] Calibration transfer in near infrared analysis of liquids and solids
    Wang, Q
    DeJesus, S
    Conzen, JP
    Schmidt, A
    Weiler, H
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, 1998, : A201 - A205
  • [23] Are standard sample measurements still needed to transfer multivariate calibration models between near-infrared spectrometers? The answer is not always
    Mishra, Puneet
    Nikzad-Langerodi, Ramin
    Marini, Federico
    Roger, Jean Michel
    Biancolillo, Alessandra
    Rutledge, Douglas N.
    Lohumi, Santosh
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 143
  • [24] Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers
    Zhang, Hui
    Tan, Haining
    Lin, Boran
    Yang, Xiangchun
    Sun, Zhongyu
    Zhong, Liang
    Gao, Lele
    Li, Lian
    Dong, Qin
    Nie, Lei
    Zang, Hengchang
    MOLECULES, 2023, 28 (01):
  • [25] Calibration transfer between miniature photodiode array-based spectrometers in the near infrared assessment of mandarin soluble solids content
    Greensill, CV
    Walsh, KB
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2002, 10 (01) : 27 - 35
  • [26] COMPARISON OF SPECTRAL RESPONSE OF NEAR-INFRARED SPECTROMETERS USED FOR ROUTINE ANALYSES .2. STUDY OF THE TRANSFER OF CALIBRATION BETWEEN INSTRUMENTS
    DESAINTDO, I
    BERTRAND, D
    ANALUSIS, 1990, 18 (03) : 157 - 161
  • [27] Measuring glucose blood with spectroscopy skin in near infrared
    Marius, Ionescu
    Sever, Pasca
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTERS AND ARTIFICIAL INTELLIGENCE (ECAI-2019), 2019,
  • [28] Calibration of a visible and near-infrared portable transfer radiometer
    Biggar, SF
    METROLOGIA, 1998, 35 (04) : 701 - 706
  • [29] CALIBRATION TRANSFER BETWEEN NEAR-INFRARED REFLECTANCE SPECTROPHOTOMETERS
    SHENK, JS
    WESTERHAUS, MO
    TEMPLETON, WC
    CROP SCIENCE, 1985, 25 (01) : 159 - 161
  • [30] Near-infrared calibration transfer based on spectral regression
    Peng, Jiangtao
    Peng, Silong
    Jiang, An
    Tan, Jie
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2011, 78 (04) : 1315 - 1320