Calibration transfer across near infrared spectrometers for measuring hematocrit in the blood of grazing cattle

被引:10
|
作者
Luo, Xuan [1 ]
Ikehata, Akifumi [1 ]
Sashida, Kunio [2 ]
Piao, Shanji [2 ]
Okura, Tsutomu [2 ]
Terada, Yutaka [3 ]
机构
[1] NARO, Natl Food Res Inst, 2-1-12 Kannondai, Tsukuba, Ibaraki 3058642, Japan
[2] Soma Opt Ltd, Tokyo, Japan
[3] NARO, Natl Inst Anim Hlth, 3-1-5 Kannondai, Tsukuba, Ibaraki, Japan
关键词
Anemia; hematocrit; calibration transfer; robust model; wavelength selection; skew and bias correction; piecewise direct standardization; MULTIVARIATE INSTRUMENT STANDARDIZATION; SOLUBLE SOLIDS CONTENT; PARTIAL LEAST-SQUARES; WAVELENGTH SELECTION; REGRESSION; SPECTROSCOPY; REFLECTANCE; IMPROVEMENT; SPECTRA; ARRAY;
D O I
10.1177/0967033516686658
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
For fast diagnosis of anemia for cattle farmed on pastures, portable short wavelength near infrared spectrometer instrument was built, and the feasibility of estimating hematocrit by partial least squares regression modeling was validated in our previous work. As a follow-up, the present study reports calibration transfer from one master instrument to two slave instruments. Different approaches, i.e. making robust models, skew and bias correction, and piecewise direct standardization, were compared. Our results show that making more use of simple models based on appropriate preprocessing, number of latent variables, and wavelength selection, can sometimes be as effective as applying standardization algorithm (e.g. piecewise direct standardization) when tackling the spectral differences between instruments. The importance of a robust model during the process of calibration transfer is shown. Application of standardization such as piecewise direct standardization could be risky when the model to be transferred is not robust enough.
引用
收藏
页码:15 / 25
页数:11
相关论文
共 50 条
  • [1] CALIBRATION TRANSFER AND MEASUREMENT STABILITY OF NEAR-INFRARED SPECTROMETERS
    WANG, YD
    KOWALSKI, BR
    APPLIED SPECTROSCOPY, 1992, 46 (05) : 764 - 771
  • [2] Calibration transfer of spectra from near infrared spectrometers by Procrustes analysis
    Chu, XL
    Yuan, HF
    Lu, WZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (01) : 114 - 119
  • [3] Forage calibration transfer from laboratory to portable near infrared spectrometers
    Yang, Xueping
    Cherney, J. H.
    Casler, M. D.
    Berzaghi, Paolo
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2023, 31 (03) : 126 - 140
  • [4] Calibration transfer of near infrared spectrometers for the assessment of plasma ethanol precipitation process
    Sun, Zhongyu
    Wang, Jiayue
    Nie, Lei
    Li, Lian
    Cao, Dawei
    Fan, Jiajin
    Wang, Haiyan
    Liu, Ruichen
    Zhang, Yinran
    Zang, Hengchang
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2018, 181 : 64 - 71
  • [5] A PHANTOM FOR THE TESTING AND CALIBRATION OF NEAR-INFRARED SPECTROMETERS
    FIRBANK, M
    DELPY, DT
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (09): : 1509 - 1513
  • [6] Calibration Transfer between Two Near-Infrared Spectrometers Based on a Wavelet Packet Transform
    Chao Tan
    Menglong Li
    Analytical Sciences, 2007, 23 : 201 - 206
  • [7] Calibration transfer between two near-infrared spectrometers based on a wavelet packet transform
    Tan, Chao
    Li, Menglong
    ANALYTICAL SCIENCES, 2007, 23 (02) : 201 - 206
  • [8] Transfer of a calibration model for the prediction of lignin in pulpwood among four portable near infrared spectrometers
    Zhang, Xiaoxue
    Chen, Xinyu
    Xiong, Zhixin
    Siesler, Heinz W.
    Liang, Long
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2022, 30 (04) : 208 - 218
  • [9] Improved calibration transfer between near-Infrared (NIR) spectrometers using canonical correlation analysis
    Yang, Junxing
    Lou, Xiaoping
    Yang, Hongqi
    Yang, Huibing
    Liu, Chaoying
    Wu, Jingjing
    Bin, Jun
    ANALYTICAL LETTERS, 2019, 52 (14) : 2188 - 2202
  • [10] CALIBRATION OF GRAZING-INCIDENCE SPECTROMETERS USING CHARGE-TRANSFER EXCITATION
    ISLER, RC
    LANGLEY, RA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (05): : 868 - 868