First results from a macromolecular crystallography system with a polycapillary collimating optic and a microfocus X-ray generator

被引:15
|
作者
Gubarev, M
Ciszak, E
Ponomarev, I
Gibson, W
Joy, M [1 ]
机构
[1] NASA, George C Marshall Space Flight Ctr, Huntsville, AL 35812 USA
[2] Natl Res Council, Washington, DC 20418 USA
[3] Univ Space Res Assoc, Huntsville, AL 35805 USA
[4] Xray Opt Syst Inc, Albany, NY 12203 USA
[5] SUNY Albany, Ctr Xray Opt, Albany, NY 12222 USA
关键词
D O I
10.1107/S0021889800001837
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The design and performance of a high-flux X-ray crystallography system, optimized for diffraction measurements from small macromolecular crystals, is described. This system combines a microfocus X-ray generator [40 mu m full width at half-maximum (FWHM) spot size at a power level of 40 W] and a short focal length (F = 2.6 mm) polycapillary collimating optic, and produces a small-diameter quasi-parallel X-ray beam. Measurements of the X-ray flux, divergence and spectral purity of the resulting X-ray beam are presented. The X-ray flux through an aperture of 250 mu m diameter produced by the microfocus system is 16 times higher than that from a 3.15 kW rotating-anode generator equipped with a pyrolytic graphite monochromator. Diffraction data from lysozyme test crystals collected with the microfocus X-ray system are of high quality and can be reduced with standard crystallographic software, yielding an overall merging factor R-sym less than or equal to 6%. Significant additional improvements in flux are possible, and plans for achieving these goals are discussed.
引用
收藏
页码:882 / 887
页数:6
相关论文
共 50 条
  • [31] The complex analysis of X-ray mesh scans for macromolecular crystallography
    Melnikov, I. A.
    Bourenkov, G. B.
    Svensson, O.
    Leonard, G. A.
    Popov, A. N.
    JOURNAL OF BIOENERGETICS AND BIOMEMBRANES, 2018, 50 (06) : 562 - 563
  • [32] Validation of ligands in macromolecular structures determined by X-ray crystallography
    Smart, Oliver S.
    Horsky, Vladimir
    Gore, Swanand
    Varekova, Radka Svobodova
    Bendova, Veronika
    Kleywegt, Gerard J.
    Velankar, Sameer
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2018, 74 : 228 - 236
  • [33] Macromolecular X-ray crystallography: soon to be a road less traveled?
    Beale, J.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2020, 76 : A80 - A80
  • [34] Quantitative radiation damage studies in macromolecular X-ray crystallography
    Gerstel, Markus
    Olekhnovich, Natalya
    Brooks-Bartlett, Jonathan
    Derewenda, Zygmunt S.
    Deane, Charlotte M.
    Garman, Elspeth F.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2013, 69 : S407 - S408
  • [35] FOCUSING X-RAY BEAMLINE FOR MACROMOLECULAR CRYSTALLOGRAPHY AT THE PHOTON FACTORY
    SATOW, Y
    MIKUNI, A
    KAMIYA, N
    ANDO, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2394 - 2397
  • [36] Macromolecular X-ray crystallography: soon to be a road less travelled?
    Beale, John H.
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2020, 76 : 400 - 405
  • [37] Macromolecular crystallography at the Penn State X-ray core facility
    Yennawar, Neela
    Yennawar, Hemant
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C301 - C301
  • [38] Microfocus X-ray inspection from TWI
    不详
    INSIGHT, 2006, 48 (06) : 333 - 333
  • [39] Optimizing the spatial distribution of dose in X-ray macromolecular crystallography
    Zeldin, Oliver B.
    Gerstel, Markus
    Garman, Elspeth F.
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 49 - 57
  • [40] Micro-CT scanner with a focusing polycapillary x-ray optic
    Jorgensen, SM
    Reyes, DA
    MacDonald, CA
    Ritman, EL
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 158 - 166