Rapid Determination of Plutonium Isotopes in Environmental Samples Using Sequential Injection Extraction Chromatography and Detection by Inductively Coupled Plasma Mass Spectrometry

被引:50
|
作者
Qiao, Jixin [1 ]
Hou, Xiaolin [1 ]
Roos, Per [1 ]
Miro, Manuel [2 ]
机构
[1] Tech Univ Denmark, Riso Natl Lab Sustainable Energy, Div Radiat Res, DK-4000 Roskilde, Denmark
[2] Univ Balearic Isl, Fac Sci, Dept Chem, E-07071 Palma de Mallorca, Spain
关键词
ICP-MS DETECTION; ION CHROMATOGRAPHY; PU-ISOTOPES; ALPHA-SPECTROMETRY; SOIL SAMPLES; ACTINIDE ELEMENTS; ULTRATRACE LEVEL; ANION-EXCHANGE; WASTE SAMPLES; SEPARATION;
D O I
10.1021/ac901395e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article presents an automated method for the rapid determination of Pu-239 and Pu-240 in various environmental samples. The analytical method involves the in-line separation of Pu isotopes using extraction chromatography (TEVA) implemented in a sequential injection (SI) network followed by detection of isolated analytes with inductively coupled plasma mass spectrometry (ICP-MS). The method has been devised for the determination of Pu isotopes at environmentally relevant concentrations, whereby it has been successfully applied to the analyses of large volumes/amounts of samples, for example, 100-200 g of soil and sediment, 20 g of seaweed, and 200 L of seawater following analyte preconcentration. The investigation of the separation capability of the assembled SI system revealed that up to 200 g of soil or sediment can be treated using a column containing about 0.70 g of TEVA resin. The analytical results of Pu isotopes in the reference materials showed good agreement with the certified or reference values at the 0.05 significance level. Chemical yields of Pu ranged from 80 to 105%, and the decontamination factors for uranium, thorium, mercury and lead were all above 10(4). The duration of the in-line extraction chromatographic run was <1.5 h, and the proposed setup was able to handle up to 20 samples (14 mL each) in a fully automated mode using a single chromatographic column. The SI manifold is thus suitable for rapid and automated determination of Pu isotopes in environmental risk assessment and emergency preparedness scenarios.
引用
收藏
页码:8185 / 8192
页数:8
相关论文
共 50 条
  • [31] Rapid Determination of Dissolved Phosphorus in Environmental Waters Using Inductively Coupled Plasma Tandem Mass Spectrometry
    Ma Xu
    Liu Ning
    Xu Jian-Qiao
    Guan Peng
    Mu De-Hai
    Guo Peng-Ran
    Ouyang Gang-Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (08) : E1863 - E1867
  • [32] Rapid determination of iodine in soils using inductively coupled plasma mass spectrometry
    Mani, Devleena
    Rao, T. Gnaneshwar
    Balaram, V.
    Dayal, A. M.
    Kumar, B.
    CURRENT SCIENCE, 2007, 93 (09): : 1219 - 1221
  • [33] Determination of plutonium isotopes in environmental samples by extraction chromatography with triisooctylamine - polyethylene resin
    Popov, L.
    APPLIED RADIATION AND ISOTOPES, 2019, 146 : 48 - 56
  • [34] High-Throughput Sequential Injection Method for Simultaneous Determination of Plutonium and Neptunium in Environmental Solids Using Macroporous Anion-Exchange Chromatography, Followed by Inductively Coupled Plasma Mass Spectrometric Detection
    Qiao, Jixin
    Hou, Xiaolin
    Roos, Per
    Miro, Manuel
    ANALYTICAL CHEMISTRY, 2011, 83 (01) : 374 - 381
  • [35] Ion chromatography inductively coupled plasma mass spectrometry determination of arsenic species in marine samples
    Karthikeyan, S
    Hirata, S
    APPLIED ORGANOMETALLIC CHEMISTRY, 2004, 18 (07) : 323 - 330
  • [36] Determination of vanadium species in water samples by liquid chromatography inductively coupled plasma mass spectrometry
    Wann, CC
    Jiang, SJ
    ANALYTICA CHIMICA ACTA, 1997, 357 (03) : 211 - 218
  • [37] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    S. Tonouchi
    H. Habuki
    K. Katoh
    K. Yamazaki
    T. Hashimoto
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 252 : 367 - 371
  • [38] Determination of selected nickel isotopes in biological samples by inductively coupled plasma mass spectrometry with isotope dilution
    Patriarca, M
    Lyon, TDB
    McGaw, B
    Fell, GS
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (04) : 297 - 302
  • [39] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    Tonouchi, S
    Habuki, H
    Katoh, K
    Yamazaki, K
    Hashimoto, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 252 (02) : 367 - 371
  • [40] Determination of iodine in food samples by inductively coupled plasma mass spectrometry after alkaline extraction
    Fecher, PA
    Goldmann, I
    Nagengast, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) : 977 - 982