Rapid Determination of Plutonium Isotopes in Environmental Samples Using Sequential Injection Extraction Chromatography and Detection by Inductively Coupled Plasma Mass Spectrometry

被引:48
|
作者
Qiao, Jixin [1 ]
Hou, Xiaolin [1 ]
Roos, Per [1 ]
Miro, Manuel [2 ]
机构
[1] Tech Univ Denmark, Riso Natl Lab Sustainable Energy, Div Radiat Res, DK-4000 Roskilde, Denmark
[2] Univ Balearic Isl, Fac Sci, Dept Chem, E-07071 Palma de Mallorca, Spain
关键词
ICP-MS DETECTION; ION CHROMATOGRAPHY; PU-ISOTOPES; ALPHA-SPECTROMETRY; SOIL SAMPLES; ACTINIDE ELEMENTS; ULTRATRACE LEVEL; ANION-EXCHANGE; WASTE SAMPLES; SEPARATION;
D O I
10.1021/ac901395e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article presents an automated method for the rapid determination of Pu-239 and Pu-240 in various environmental samples. The analytical method involves the in-line separation of Pu isotopes using extraction chromatography (TEVA) implemented in a sequential injection (SI) network followed by detection of isolated analytes with inductively coupled plasma mass spectrometry (ICP-MS). The method has been devised for the determination of Pu isotopes at environmentally relevant concentrations, whereby it has been successfully applied to the analyses of large volumes/amounts of samples, for example, 100-200 g of soil and sediment, 20 g of seaweed, and 200 L of seawater following analyte preconcentration. The investigation of the separation capability of the assembled SI system revealed that up to 200 g of soil or sediment can be treated using a column containing about 0.70 g of TEVA resin. The analytical results of Pu isotopes in the reference materials showed good agreement with the certified or reference values at the 0.05 significance level. Chemical yields of Pu ranged from 80 to 105%, and the decontamination factors for uranium, thorium, mercury and lead were all above 10(4). The duration of the in-line extraction chromatographic run was <1.5 h, and the proposed setup was able to handle up to 20 samples (14 mL each) in a fully automated mode using a single chromatographic column. The SI manifold is thus suitable for rapid and automated determination of Pu isotopes in environmental risk assessment and emergency preparedness scenarios.
引用
收藏
页码:8185 / 8192
页数:8
相关论文
共 50 条
  • [1] Rapid isolation of plutonium in environmental solid samples using sequential injection anion exchange chromatography followed by detection with inductively coupled plasma mass spectrometry
    Qiao, Jixin
    Hou, Xiaolin
    Roos, Per
    Miro, Manuel
    ANALYTICA CHIMICA ACTA, 2011, 685 (02) : 111 - 119
  • [2] Automated flow injection system using extraction chromatography for the determination of plutonium in urine by inductively coupled plasma mass spectrometry
    Lariviere, Dominic
    Cumming, Thomas A.
    Kiser, Stephen
    Li, Chunsheng
    Cornett, R. Jack
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (03) : 352 - 360
  • [3] Determination of fetogram plutonium by extraction chromatography using isotope dilution inductively coupled plasma mass spectrometry
    Jin, YR
    Zhang, LZ
    Han, SJ
    Zhu, FR
    Bai, JF
    Zhou, GQ
    Ma, F
    Zhang, LX
    ACTA CHIMICA SINICA, 2000, 58 (10) : 1291 - 1295
  • [4] High resolution inductively coupled plasma mass spectrometry for the trace determination of plutonium isotopes and isotope ratios in environmental samples
    Stürup, S
    Dahlgaard, H
    Nielsen, SC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (12) : 1321 - 1326
  • [5] Rapid and simultaneous determination of neptunium and plutonium isotopes in environmental samples by extraction chromatography using sequential injection analysis and ICP-MS
    Qiao, Jixin
    Hou, Xiaolin
    Roos, Per
    Miro, Manuel
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (11) : 1769 - 1779
  • [6] Determination of plutonium isotopes and neptunium-237 in environmental samples by inductively coupled plasma mass spectrometry with total sample dissolution
    Kenna, Timothy C.
    Journal of Analytical Atomic Spectrometry, 2002, 17 (11): : 1471 - 1479
  • [7] Determination of plutonium isotopes and neptunium-237 in environmental samples by inductively coupled plasma mass spectrometry with total sample dissolution
    Kenna, TC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (11) : 1471 - 1479
  • [8] Rapid determination of Pu isotopes for decommission concrete samples by inductively coupled plasma mass spectrometry
    Wang, Zhongtang
    Wen, Wei
    Quan, Wei
    Du, Liang
    Wang, Ping
    Lin, Jinxian
    Xie, Yun
    Tan, Zhaoyi
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 316 (01) : 411 - 417
  • [9] Rapid determination of Pu isotopes for decommission concrete samples by inductively coupled plasma mass spectrometry
    Zhongtang Wang
    Wei Wen
    Wei Quan
    Liang Du
    Ping Wang
    Jinxian Lin
    Yun Xie
    Zhaoyi Tan
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 316 : 411 - 417
  • [10] Determination of plutonium and americium in environmental samples by inductively coupled plasma sector field mass spectrometry and alpha spectrometry
    Varga, Zsolt
    Suranyi, Gergely
    Vajda, Nora
    Stefanka, Zsolt
    MICROCHEMICAL JOURNAL, 2007, 85 (01) : 39 - 45