Fully threaded headless compression screw versus partially threaded cancellous lag screw in medial malleolus fractures: clinical and radiological outcomes

被引:7
|
作者
Bulut, Tugrul [1 ]
Gursoy, Merve [2 ]
Ertem, Hakan [1 ]
机构
[1] Izmir Katip Celebi Univ, Dept Orthopaed & Traumatol, Ataturk Training & Res Hosp, TR-35360 Izmir, Turkey
[2] Izmir Democracy Univ, Dept Radiol, Fac Med, Izmir, Turkey
关键词
Medial malleolar fracture; Ankle fracture; Headless compression screw; Cancellous lag screw;
D O I
10.1007/s00068-019-01207-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose The aim of this study was to evaluate the clinical and radiological results of medial malleolar fractures, which were treated with fully threaded headless compression screws and to compare the clinical and radiological results of this screws and partially threaded cancellous lag screws. Methods Sixty-one patients who attended the final follow-up examination were included in the study. Group 1 comprised 29 patients applied with fully threaded headless compression screws and Group 2 comprised 32 patients with partially threaded cancellous lag screws. Radiological evaluation was made with standard radiographs. The clinical evaluations were applied using the AOFAS ankle hindfoot scale. Pain or sensitivity by touching over the medial malleolus was recorded and scored according to Visual Analog Scale. Results No significant differences were determined between the groups with respect to age, gender, fracture type, follow-up time, bone union time and AOFAS scores. The medial sensitivity associated with implant irritation was significantly lower in Group 1. There was no need for removal of the fixation material in any patient of Group 1. Conclusions The results of this study showed satisfactory results in the two fixation techniques in medial malleolar fractures. However, the rates of medial sensitivity associated with implant irritation were lower in the group where fully threaded headless compression screws were used. Therefore, to prevent postoperative patient dissatisfaction caused by persistent medial sensitivity associated with implant irritation, despite successful surgical treatment, the primary choice may be fully threaded headless compression screws.
引用
收藏
页码:179 / 185
页数:7
相关论文
共 50 条
  • [31] A comparative study of early functional outcomes in undisplaced neck of femur fracture treated with partially threaded and fully threaded cannulated screw fixation in patients above 60 years age
    Awais, Muhammad Zarak
    Salik, Eman
    Bokhari, Syed Hassan Raza
    Iqbal, Muhammad Tahir
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2023, 39 (05) : 1531 - 1534
  • [32] Prospective study of treatment outcomes with lag screw versus Herbert screw fixation in mandibular fractures
    Kotrashetti, S. M.
    Singh, A. G.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 46 (01) : 54 - 58
  • [33] Syndesmosis Fixation in Unstable Ankle Fractures Using a Partially Threaded 5.0-mm Cannulated Screw
    Lee, Seung Yeol
    Moon, Sang Young
    Park, Moon Seok
    Jo, Byung Chae
    Jeong, Hyunseok
    Lee, Kyoung Min
    JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (04): : 721 - 725
  • [34] Biomechanical comparison of nitinol compression staples versus fully threaded lag screws for talonavicular arthrodesis
    Reddy, P. J.
    Manning, B. T.
    Bezold, W.
    Garlapaty, A.
    Cook, J. L.
    Schweser, K.
    JOURNAL OF ORTHOPAEDICS, 2023, 37 : 64 - 68
  • [35] Comparison of a standard locking screw versus a double-threaded cortical compression screw for fixation of die-punch fragments in distal radius fractures with volar plating
    Muccioli, C.
    Diaz, J. J. Hidalgo
    Pizza, C.
    Gouzou, S.
    Facca, S.
    Liverneaux, P.
    HAND SURGERY & REHABILITATION, 2020, 39 (01): : 30 - 35
  • [36] LAG-SCREW OSTEOSYNTHESIS OF MANDIBULAR CONDYLE FRACTURES - A CLINICAL AND RADIOLOGICAL STUDY
    KALLELA, I
    SODERHOLM, AL
    PAUKKU, P
    LINDQVIST, C
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 53 (12) : 1397 - 1404
  • [37] Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures
    Li, Jiantao
    Wang, Menglin
    Li, Lianting
    Zhang, Hao
    Hao, Ming
    Li, Chen
    Han, Lin
    Zhou, Jianfeng
    Wang, Kun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [38] Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures
    Jiantao Li
    Menglin Wang
    Lianting Li
    Hao Zhang
    Ming Hao
    Chen Li
    Lin Han
    Jianfeng Zhou
    Kun Wang
    Journal of Orthopaedic Surgery and Research, 13
  • [39] Intramedullary Threaded Nail Fixation Versus Plate and Screw Construct in Metacarpal Neck Fractures: A Biomechanical Study
    Wallace, Doyle R.
    Shiver, A. Luke
    Pulliam, Steven K.
    Byrd, Bruce M.
    McGee-Lawrence, Meghan E.
    Snoddy, Mark C.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2023, 31 (11) : E516 - E522
  • [40] Is bioabsorbable screw an alternative choice for displaced medial epicondylar fractures in adolescents A comparative study of metallic cannulated lag screw versus bioabsorbable screw
    Li, Jin
    Rai, Saroj
    Ze, Renhao
    Tang, Xin
    Liu, Ruikang
    Hong, Pan
    MEDICINE, 2020, 99 (35)