Analysis of synchronous generator internal faults based on fractal

被引:0
|
作者
Fang, Hongwei [1 ]
Xia, Changliang [1 ]
Jin, Xuefeng [1 ]
Xiu, Jie [1 ]
机构
[1] Tianjin Univ, Sch Elect Engn & Automat, Tianjin 300072, Peoples R China
关键词
generator; internal fault; fractal dimension; rescaled range analysis; dynamic simulative experiment;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The parameter waveforms of synchronous generator are related closely to their operating conditions, which can reflect and foresee some certain states or faults to occur in generator. The chaos and fractal theory is used to synthetically analyze parameter waveforms in this paper. The steady and transient process of synchronous generator with internal fault has been investigated based on the Rescaled Range analysis. Through fractal dimension analysis of the simulative and experimental data respectively, two main useful laws are obtained. Firstly, transient waveform's fractal dimension is a quantitative representation of generator's internal fault type and have great relevancy with its spectrum distribution. Secondly, the steady and transient state fault pattern can be detected by using R/S analysis method to some extent, but it should combine with other method before it can be applied into practice. These results provide new criterions for the protection and fault detection of the generator with internal fault.
引用
收藏
页码:7503 / 7507
页数:5
相关论文
共 50 条
  • [11] A new model of synchronous machine internal faults based on winding distribution
    Tu, Xiaoping
    Dessaint, Louis-A.
    El Kahel, Mohammed
    Barry, Alpha O.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (06) : 1818 - 1828
  • [12] Impacts of Flickers, Harmonics and Faults on Synchronous Generator Operations
    Fan, Wen
    Liao, Yuan
    2012 44TH SOUTHEASTERN SYMPOSIUM ON SYSTEM THEORY (SSST), 2012, : 220 - 225
  • [13] A synchronous machine model to analyze internal faults
    Muthumuni, D
    McLaren, PG
    Dirks, E
    Pathirana, V
    CONFERENCE RECORD OF THE 2001 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2001, : 1595 - 1600
  • [14] Thermal Analysis of Internal Short-Circuit Faults in Stator Windings of Multiphase Permanent Magnet Synchronous Generator with Rectifier-load System
    Tian, Daizong
    Sun, Yuguang
    Du, Wei
    Gui, Lin
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 1271 - 1276
  • [15] Magnetic Saturation Effects in a Synchronous Generator During Unbalanced Faults
    Louie, Kwok-Wai K. W.
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2006, 6 (02): : 1 - 19
  • [16] Experimental Platform for Controlled Faults on Synchronous Generator Armature Windings
    Monaro, Renato Machado
    Vieira, Jose C. M.
    Coury, Denis Vinicius
    Malik, Om P.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (04) : 948 - 957
  • [17] Transient Response of Synchronous Generator to Faults on the Evacuation Overhead Line
    Dilertea, Flaviu
    Surianu, Flavius-Dan
    2018 INTERNATIONAL CONFERENCE ON APPLIED AND THEORETICAL ELECTRICITY (ICATE), 2018,
  • [18] Experimental Platform for Controlled Faults on Synchronous Generator Armature Windings
    Monaro, Renato
    Viera, Jose
    Coury, Denis
    Malik, Om
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [19] FAST GENERATOR PROTECTION AGAINST INTERNAL ASYMMETRICAL FAULTS
    DASH, PK
    MALIK, OP
    HOPE, GS
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (05): : 1498 - 1506
  • [20] Analysis for Impacts of Internal Impedance on the Load Characteristic of a Permanent Magnet Synchronous Generator
    Shen, Yue
    Zhang, Lingtan
    Sheng, Limin
    Li, Lin
    THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 1135 - +