Digital breast tomosynthesis: Image acquisition principles and artifacts

被引:20
|
作者
Sujlana, Parvinder S. [2 ]
Mahesh, Mahadevappa [2 ]
Vedantham, Srinivasan [3 ]
Harvey, Susan C. [2 ]
Mullen, Lisa A. [2 ]
Woods, Ryan W. [1 ]
机构
[1] Univ Wisconsin, Dept Radiol, Sch Med & Publ Hlth, 600 Highland Ave, Madison, WI 53792 USA
[2] Johns Hopkins Med Inst, Russell H Morgan Dept Radiol & Radiol Sci, 601 N Wolfe St, Baltimore, MD 21287 USA
[3] Univ Arizona, Banner Univ Med Ctr, 1609 N Warren Ave, Tucson, AZ 85719 USA
关键词
Digital breast tomosynthesis; Synthesized mammograms; Physics; Artifacts; MAMMOGRAPHY; PERFORMANCE; PARAMETERS; PROJECTION; REDUCTION; MORTALITY; QUALITY; PHANTOM;
D O I
10.1016/j.clinimag.2018.07.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital breast tomosynthesis (DBT) is a new technology that is being used more frequently for both breast cancer screening and diagnostic purposes and its utilization is likely to continue to increase over time. The major benefit of tomosynthesis over 2D-mammography is that it allows radiologists to view breast tissue using a three-dimensional dataset and improves diagnostic accuracy by facilitating differentiation of potentially malignant lesions from overlap of normal tissue. In addition, image processing techniques allow reconstruction of two dimensional synthesized mammograms (SM) from DBT data, which eliminates the need for acquiring two dimensional full field digital mammography (FFDM) in addition to tomosynthesis and thereby reduces the radiation dose. DBT systems incorporate a moveable x-ray tube, which moves in a prescribed way over a limited angular range to obtain three-dimensional data of patients' breasts, and utilize reconstruction algorithms. The limited angular range for DBT leads to incomplete sampling of the object, and a movable x-ray tube prolongs the imaging time, both of which make DBT and SM susceptible to artifacts. Understanding the etiology of these artifacts should help radiologists in reducing the number of artifacts and in differentiating a true finding from one related to an artifact, thus potentially decreasing recall rates and false positive rates. This is becoming especially important with increased incorporation of DBT in practices around the world. The goal of this article is to review the physics principles behind DBT systems and use these principles to explain the origin of artifacts that can limit diagnostic evaluation.
引用
收藏
页码:188 / 195
页数:8
相关论文
共 50 条
  • [41] Digital Mammography and Digital Breast Tomosynthesis
    Moseley, Tanya W.
    [J]. CLINICAL OBSTETRICS AND GYNECOLOGY, 2016, 59 (02): : 362 - 379
  • [42] A review of breast tomosynthesis. Part I. The image acquisition process
    Sechopoulos, Ioannis
    [J]. MEDICAL PHYSICS, 2013, 40 (01)
  • [43] Calcifications in the Breast and Digital Breast Tomosynthesis
    Kopans, Daniel
    Gavenonis, Sara
    Halpern, Elkan
    Moore, Richard
    [J]. BREAST JOURNAL, 2011, 17 (06): : 638 - 644
  • [44] Enhancing tissue structures with iterative image reconstruction for digital breast tomosynthesis
    Sidky, Emil Y.
    Reiser, Ingrid S.
    Nishikawa, Robert M.
    Pan, Xiaochuan
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [45] 3D Medical Image Reconstruction on Digital Breast Tomosynthesis
    Duarte, Isabel Catarina
    Janela, Filipe
    Caldeira, Liliana
    Soares, Filipe
    Silva, Jose Silvestre
    [J]. 2012 IEEE 2ND PORTUGUESE MEETING IN BIOENGINEERING (ENBENG), 2012,
  • [46] Improving depth resolution in digital breast tomosynthesis by iterative image reconstruction
    Roth, Erin G.
    Kraemer, David N.
    Sidky, Emil Y.
    Reiser, Ingrid S.
    Pan, Xiaochun
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [47] Multiscale bilateral filtering for improving image quality in digital breast tomosynthesis
    Lu, Yao
    Chan, Heang-Ping
    Wei, Jun
    Hadjiiski, Lubomir M.
    Samala, Ravi K.
    [J]. MEDICAL PHYSICS, 2015, 42 (01) : 182 - 195
  • [48] Use of the Hotelling observer to optimize image reconstruction in digital breast tomosynthesis
    Sanchez, Adrian A.
    Sidky, Emil Y.
    Pan, Xiaochuan
    [J]. JOURNAL OF MEDICAL IMAGING, 2016, 3 (01)
  • [49] Statistical iterative reconstruction to improve image quality for digital breast tomosynthesis
    Xu, Shiyu
    Lu, Jianping
    Zhou, Otto
    Chen, Ying
    [J]. MEDICAL PHYSICS, 2015, 42 (09) : 5377 - 5390
  • [50] RELATIONSHIP BETWEEN RADIATION DOSE AND IMAGE QUALITY IN DIGITAL BREAST TOMOSYNTHESIS
    Alakhras, Maram M.
    Mello-Thoms, Claudia
    Bourne, Roger
    Rickard, Mary
    Diffey, Jennifer
    Brennan, Patrick C.
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 173 (04) : 351 - 360