Determination of sodium and potassium contents in palm-based polyols using graphite furnace atomic absorption spectrometer

被引:1
|
作者
Ramli, Nur Aainaa Syahirah [1 ]
Noor, Mohd Azmil Mohd [1 ]
Ismail, Tuan Noor Maznee Tuan [1 ]
机构
[1] Malaysian Palm Oil Board MPOB, Qual & Environm Assessment Unit, Adv Oleochem Technol Div, Persiaran Institusi, Kajang 43000, Selangor, Malaysia
关键词
Graphite furnace atomic absorption spectrometer; Sodium; Potassium; Palm-based polyol; Dissolution;
D O I
10.1007/s11696-020-01493-8
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the production of palm-based polyols (PBP), multiple purification steps might introduce sodium (Na) and potassium (K) into the polyols. The Na and K have potential to influence reactivity of polyether polyols with isocyanate in polyurethane (PU) production. The Na and K contents in polyether polyols for PU production are both limited to 10 mg kg(-1). This study focuses on method(s) development for determination of Na and K in PBP by graphite furnace atomic absorption spectrometer (GF AAS) using dilution in isopropyl alcohol as a sample preparation method. All measurements were performed without any chemical modifier. In GF AAS analysis, it is essential to establish the optimum temperature program which includes pyrolysis and atomization temperature. At the optimized condition, the developed method was validated according to the validation protocol described by International Conference on Harmonization (ICH) and AOAC International. Several parameters were evaluated include linearity of calibration curve, limit of detection (LOD), limit of quantitation (LOQ), sensitivity, recovery, and precision. The optimization of temperature program for both Na and K determinations deduced the optimum pyrolysis and atomization temperature of 900 and 1600 degrees C, respectively. The method for Na determination concludes as follows: the analytical curve showed linear correlation with R-2 value of 0.9928. The LOD and LOQ were 0.307 and 1.025 mu g kg(-1), respectively. Recoveries in the range of 97 to 108% were obtained from spiked samples (4-12 mu g kg(-1)). Whereas, the method for K determination deduces as follows: the analytical curve showed linear correlation with R-2 value of 0.9985. The LOD and LOQ were 0.249 and 0.829 mu g kg(-1), respectively. Recoveries in the range of 90-109% were obtained from spiked samples (4-12 mu g kg(-1)). The Na and K contents obtained from the developed GF AAS method are in agreement with inductively coupled plasma optical emission spectrometry (ICP OES) with 95% confidence level. The Na and K contents in PBP samples were within the limit allowed for PU production.
引用
收藏
页码:2561 / 2574
页数:14
相关论文
共 50 条
  • [31] Direct and simultaneous determination of arsenic, manganese, cobalt and nickel in urine with a multielement graphite furnace atomic absorption spectrometer
    Hsiang, MC
    Sung, YH
    Huang, SD
    TALANTA, 2004, 62 (04) : 791 - 799
  • [32] Direct and simultaneous determination of copper, chromium, aluminum, and manganese in urine with a multielement graphite furnace atomic absorption spectrometer
    Lin, TW
    Huang, SD
    ANALYTICAL CHEMISTRY, 2001, 73 (17) : 4319 - 4325
  • [33] DETERMINATION OF GERMANIUM BY ATOMIC ABSORPTION SPECTROMETRY USING THE GRAPHITE FURNACE PLATFORM TECHNIQUE.
    Gao Ying-qi
    Ni Zhe-ming
    Xi You Jin Shu/Rare Metals, 1982, 1 (01): : 57 - 60
  • [34] DETERMINATION OF MOLYBDENUM IN PLASMA USING GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY
    MORRICE, PC
    HUMPHRIES, WR
    BREMNER, I
    ANALYST, 1989, 114 (12) : 1667 - 1669
  • [35] Direct determination of chromium in sugar and milk using graphite furnace atomic absorption spectrometry
    Quináia, SP
    Nóbrega, JA
    QUIMICA NOVA, 2000, 23 (02): : 185 - 190
  • [36] Graphite Furnace Atomic Absorption Spectrophotometric Determination of Trace Horseradish Peroxidase Using Nanosilver
    Jiang Zhi-liang
    Tang Ya-fang
    Wei Lin
    Liang Ai-hui
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (08): : 2732 - 2736
  • [37] Determination of aluminum in moisturizing body lotions using graphite furnace atomic absorption spectrometry
    Castilho, Ivan N. B.
    de Quadros, Daiane P. C.
    Mior, Renata
    Welz, Bernhard
    Carasek, Eduardo
    Borges, Daniel L. G.
    ANALYTICAL METHODS, 2015, 7 (22) : 9636 - 9640
  • [38] DETERMINATION OF SODIUM AND POTASSIUM IN WINE BY ATOMIC ABSORPTION SPECTROPHOTOMETRY
    HILL, GL
    CAPUTI, A
    AMERICAN JOURNAL OF ENOLOGY AND VITICULTURE, 1969, 20 (04): : 227 - &
  • [39] DETERMINATION OF SODIUM AND POTASSIUM IN NANOLITER VOLUMES OF BIOLOGICAL-FLUIDS BY FURNACE ATOMIC-ABSORPTION SPECTROMETRY
    NASH, LA
    PETERSON, LN
    NADLER, SP
    LEVINE, DZ
    ANALYTICAL CHEMISTRY, 1988, 60 (21) : 2413 - 2418
  • [40] Determination of the temperature of the graphite probe surface in graphite probe furnace atomic absorption spectrometry
    Chakrabarti, CL
    Chen, JG
    Grenier, M
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (11) : 1335 - 1343