Measurement of coronary flow reserve in the anterior and posterior descending coronary arteries by transthoracic Doppler ultrasound

被引:71
|
作者
Voci, P
Pizzuto, F
Mariano, E
Puddu, PE
Chiavari, PA
Romeo, F
机构
[1] Univ Roma La Sapienza, Sect Cardiol 2, Rome, Italy
[2] Univ Roma Tor Vergata, Dept Cardiol, Rome, Italy
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2002年 / 90卷 / 09期
关键词
D O I
10.1016/S0002-9149(02)02666-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We describe for the first time transthoracic Doppler ultrasound assessment of coronary flow reserve (CFR) in both the posterior descending (PDA) and left anterior descending (LAD) coronary arteries. CFR (hyperemic/resting diastolic flow velocity ratio) was measured by 90-second intravenous adenosine infusion (140 mug/kg/min). Baseline PDA,flow was detected in 62 of 81 subjects (76%), and the CFR was measurable in 44 of them (54%) because of adenosine-induced hyperventilation. According to angiography, these 44 subjects were divided into 3 groups: group 1 (0% to 29% stenosis), group 2 (30% to 69% stenosis), and group 3 (greater than or equal to70% stenosis). PDA CFR was 2.62 +/- 0.25 in 17 patients in group 1, 2.33 +/- 0.32 in 9 patients in group 2, and 1.40 +/- 0.54 in 18 patients in group 3 (F = 41.83, p <0.0001). LAD CFR was 3.31 +/- 0.54 in 15 patients in group 1, 2.49 +/- 0.71 in 10 patients in group 2, and 1.12 +/- 0.49 in 19 patients in group 3 (F = 65.68, p <0.0001). A cut-off of <2 identified >= 70% stenosis in both of the arteries supplying the PDA and in the LAD. Noninvasive measurement of PDA CFR is feasible and may improve with technologic advancement and the use of selective adenosine receptor agonists, thus preventing hyperventilation. (C) 2002 by Excerpta Medica, Inc.
引用
收藏
页码:988 / 991
页数:4
相关论文
共 50 条
  • [21] Accelerated stenotic flow in the left anterior descending coronary artery explains the causes of impaired coronary flow reserve: an integrated transthoracic enhanced Doppler study
    Caiati, Carlo
    Pollice, Paolo
    Iacovelli, Fortunato
    Sturda, Francesca
    Lepera, Mario Erminio
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [22] Measurement of coronary flow velocity reserve in the left anterior descending coronary artery using transthoracic Doppler echocardiography: Results from 100 consecutive patients who underwent coronary angiography
    Yoshitani, H
    Takeuchi, M
    Miyazaki, C
    Takagi, Y
    Otani, S
    Sakamoto, K
    CIRCULATION, 2002, 106 (19) : 348 - 348
  • [23] Feasibility of noninvasive transthoracic echocardiography/Doppler measurement of coronary flow reserve in left anterior descending coronary artery in patients with acute coronary syndrome: A new technique tested in clinical practice
    Winter, R
    Gudmundsson, P
    Willenheimer, R
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (05) : 464 - 468
  • [24] Evaluation of coronary reserve in the left anterior descending coronary artery by contrast-enhanced transthoracic harmonic echo Doppler
    Caiati, C
    Montaldo, C
    Zedda, N
    Ruscazio, M
    Pirisi, R
    Iliceto, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 201A - 201A
  • [25] Feasibility of measuring coronary flow velocity and reserve in the left anterior descending coronary artery by transthoracic Doppler echocardiography in a relatively obese American population
    Takeuchi, M
    Lodato, JA
    Furlong, KT
    Lang, RM
    Yoshikawa, J
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2005, 22 (03): : 225 - 232
  • [26] Simultaneous analysis of contractility and coronary flow reserve of the anterior descending coronary artery by transthoracic Doppler echocardiography during dipyridamole echo-stress
    Lowenstein, J
    Tiano, C
    Marquez, G
    Presti, C
    EUROPEAN HEART JOURNAL, 2000, 21 : 466 - 466
  • [27] Noninvasive visualization and measurement of posterior descending coronary artery flow velocity by transthoracic Doppler echocardiography in normal children
    Aoki, M
    Harada, K
    Takada, G
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (03): : 376 - +
  • [28] Early effect of percutaneous coronary intervention of non-left anterior descending artery on coronary flow velocity reserve of left anterior descending artery assessed by transthoracic Doppler echocardiography
    Hada, Masahiro
    Hoshino, Masahiro
    Wakasa, Nobutaka
    Sugiyama, Tomoyo
    Kanaji, Yoshihisa
    Yamaguchi, Masao
    Misawa, Toru
    Nagamine, Tatsuhiro
    Nogami, Kai
    Yasui, Yumi
    Yonetsu, Taishi
    Sasano, Tetsuo
    Kakuta, Tsunekazu
    PLOS ONE, 2021, 16 (08):
  • [29] Usefulness of an echo-contrast agent for assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery with transthoracic Doppler scan echocardiography
    Okayama, H
    Sumimoto, T
    Hiasa, G
    Morioka, N
    Yamamoto, K
    Kawada, H
    AMERICAN HEART JOURNAL, 2002, 143 (04) : 668 - 675
  • [30] Transthoracic Doppler coronary flow reserve at the right coronary artery stenosis
    Boshchenko, A.
    Vrublevsky, A.
    Karpov, R.
    EUROPEAN HEART JOURNAL, 2010, 31 : 913 - 913