Use of tunable monochromatic X-ray sources for metrological studies in the low-energy range at the Laboratoire National Henri Becquerel

被引:2
|
作者
Plagnard, J. [1 ]
Lepy, M. -C. [1 ]
机构
[1] CEA Saclay, Lab Natl Henri Becquerel, F-91190 Gif Sur Yvette, France
关键词
D O I
10.1051/ndata:07195
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In the frame of the French Metrology Institute, the Laboratoire National Henri Becquerel (LNHB) performs accurate measurements of photon emission intensities in order to improve the knowledge of radionuclides decay scheme. This is achieved using semiconductor detectors, however, in the low-energy range (E < 20 keV) their efficiency calibration is not straightforward. Moreover, their energy resolution and the detailed shape of their response function are parameters of interest for accurate processing of low-energy X-ray spectra. For these purposes, and in complement to the use of classical calibration method using standard radionuclides, an original method for detectors characterization have been developed using tunable monochromatic radiation. The tunable radiation makes possible examining and identifying the different features of X-ray spectra by fine scanning at the binding energies of the detector materials, thus improving the knowledge of the detector response function and the subsequent processing of complex X-ray spectra. Since 2001, the SOLEX source (Source Of Low Energy X-rays) has been installed at LNHB and provides tunable monochromatic radiation in the 1-20 keV energy range. This facility has been applied to the measurement of photon emission intensities and attenuation coefficients of materials (Al, Cu) in the low-energy range. In the next future, the SOLEIL synchrotron facility will be equipped with a metrology beam line that will be partially managed by LNHB: this will allow subsequent development of such metrological studies with enhanced performances.
引用
收藏
页码:433 / 436
页数:4
相关论文
共 50 条
  • [41] ORIGIN OF LOW-ENERGY DIFFUSE COSMIC X-RAY FLUX
    CULHANE, JL
    FABIAN, AC
    NATURE, 1972, 237 (5355) : 379 - &
  • [42] SOME RECENT DEVELOPMENTS IN LOW-ENERGY X-RAY SPECTROSCOPY
    HENKE, BL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (08): : 1021 - 1021
  • [43] LOW-ENERGY X-RAY OBSERVATIONS OF THE WOLF 630 SYSTEM
    JOHNSON, HM
    ASTROPHYSICAL JOURNAL, 1987, 316 (01): : 458 - 461
  • [44] PRIMEVAL GAS CLOUDS AND LOW-ENERGY X-RAY BACKGROUND
    KELLOGG, EM
    ASTROPHYSICAL JOURNAL, 1977, 218 (03): : 582 - &
  • [45] LOW-ENERGY X-RAY TRANSMISSION GRATING SPECTROMETER FOR AXAF
    BRINKMAN, AC
    VANROOIJEN, JJ
    BLEEKER, JAM
    DIJKSTRA, JH
    HEISE, J
    DEKORTE, PAJ
    MEWE, R
    PAERELS, F
    ASTROPHYSICAL LETTERS & COMMUNICATIONS, 1987, 26 (1-2) : 73 - 86
  • [46] GaAs low-energy X-ray radioluminescence nuclear battery
    Zhang, Zheng-Rong
    Liu, Yun-Peng
    Tang, Xiao-Bin
    Xu, Zhi-Heng
    Yuan, Zi-Cheng
    Chen, Wang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2018, 415 : 9 - 16
  • [47] Low-energy X-ray spectral variability of NGC 4051
    Mon Not Royal Astron Soc, 3 (549):
  • [48] Qualification and performance of the Low-Energy X-ray Reflectometer (LEXR)
    Henriksen, P. L.
    Christensen, F. E.
    Massahi, S.
    Ferreira, D. D. M.
    Svendsen, S.
    Gellert, N.
    Vu, L. M.
    Jegers, A. S.
    Shortt, B.
    SPACE TELESCOPES AND INSTRUMENTATION 2020: ULTRAVIOLET TO GAMMA RAY, 2021, 11444
  • [49] SURFACE CHARACTERIZATION OF SOLIDS BY LOW-ENERGY X-RAY SPECTROMETRY
    ROMAND, M
    CHARBONNIER, M
    GAILLARD, F
    BADOR, R
    ROCHE, A
    THEVENARD, P
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1984, 9 (02): : 95 - 98
  • [50] ENTRANCE WINDOWS IN GERMANIUM LOW-ENERGY X-RAY DETECTORS
    LLACER, J
    HALLER, EE
    CORDI, RC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 53 - 60