CEMENT THICKNESS OF POST AND CORES FABRICATED BY MODERN DIGITAL TECHNOLOGY

被引:3
|
作者
Kanduti, Domen [1 ]
Kopac, Igor [2 ]
机构
[1] Univ Ljubljana, Fac Med, Dent Clin, Dept Oral Dis & Periodontol, Hrvatski Trg 6, Ljubljana 1000, Slovenia
[2] Univ Ljubljana, Fac Med, Prosthodont Dept, Dent Clin, Hrvatski Trg 6, Ljubljana 1000, Slovenia
来源
MATERIALI IN TEHNOLOGIJE | 2021年 / 55卷 / 01期
关键词
post and core; metal casting; CAD-CAM; selective laser melting; FRACTURE-RESISTANCE; CAD/CAM; DOWEL; RESTORATION; TEETH; CAST;
D O I
10.17222/mit.2020.136
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Computer-assisted digital (CAD-CAM) technologies in prosthodontics can be used for the fabrication of posts and cores. Digital techniques shorten the necessary clinical and laboratory procedures and make fabrication easier, quicker and accurate. Extracted single-rooted permanent maxillary incisors were used in the study. For each tooth one metal post was fabricated with a digital technique using SLM fabrication technology (group A) or one by casting (group B) in randomized tooth order. All the posts were cemented with zinc phosphate cement. All the teeth were sliced perpendicular to the axis of the post in four planes. The thickness of the cement layer was measured on four slices with an optical microscope with 60x and 100x magnification lens and was compared between both groups. The average cement thickness for group A was 36.76 +/- 17.29 mu m in cross-section 1, 62.38 +/- 15.24 mu m in cross-section 2, 129.42 +/- 38.37 mu m in cross-section 3, and 142.76 +/- 36.35 mu m in cross-section 4. For group B the average cement thickness was 18.18 +/- 4.6 mu m in cross-section 1, 15.36 +/- 5.41 mu m in cross-section 2, 25.41 +/- 13.42 mu m in cross-section 3, and 23.69 +/- 13.44 mu m in cross-section 4. The CAD-CAM post and core fabrication technique had a significantly larger cement thickness in all cross-sections compared to casting; however, the post accuracy was still within a clinically acceptable range.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 50 条
  • [41] Modern electro-technology in South-East Asian cement plants
    Ranze, W
    ZKG INTERNATIONAL, 1997, 50 (09): : 512 - 523
  • [42] A VISIT TO THE LENGERICH CEMENT WORKS - DISCUSSION OF EXPERIENCES WITH MODERN CONTROL ROOM TECHNOLOGY
    FROHLICH, H
    KRUDE, HJ
    ZEMENT-KALK-GIPS, 1994, 47 (06): : 359 - 361
  • [43] PRESENT STATE OF SACK PACKING AND DISPATCH TECHNOLOGY AT A MODERN CEMENT PLANT IN THAILAND
    ELSINGHORST, D
    LOWAG, HG
    ZEMENT-KALK-GIPS, 1988, 41 (08): : 381 - 385
  • [44] Present state of sack packing and dispatch technology at a modern cement plant in Thailand
    Elsinghorst, D.
    Lowag, H.G.
    ZKG international, 1988, 41 (08): : 381 - 385
  • [45] Does the thickness of the resin cement affect the bond strength of a fiber post to the root dentin?
    Perez, Bianca E. M.
    Barbosa, Silvia H.
    Melo, Renata M.
    Zamboni, Sandra C.
    Oezcan, Mutlu
    Valandro, Luiz Felipe
    Bottino, Marco A.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2006, 19 (06) : 606 - 609
  • [46] Design and measurement of very high bitrate digital ICs fabricated in InPHBT technology
    Konczykowska, A
    Blayac, S
    Jorge, F
    Riet, M
    Puyal, V
    Godin, J
    2003 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2003, : 1177 - 1180
  • [47] Using ductile cores for enhancing the mechanical performance of hollow strut β-TCP scaffolds fabricated by digital light processing
    Paredes, Claudia
    Martinez-Vazquez, Francisco J.
    Elsayed, Hamada
    Colombo, Paolo
    Pajares, Antonia
    Miranda, Pedro
    CERAMICS INTERNATIONAL, 2021, 47 (07) : 10163 - 10173
  • [48] Evaluation of Internal Fit in Custom-Made Posts and Cores Fabricated with Fully Digital Versus Conventional Techniques
    Jensen, Eric
    Sayardoust, Shariel
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (12)
  • [49] Trueness and intaglio fit of custom-made polyetheretherketone post-and-cores fabricated using different techniques
    Bassiouny, Dina
    Petersmann, Sandra
    Zohdy, Maged
    Morsi, Tarek
    Taha, Doaa
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 811 - 819
  • [50] MULTIPURPOSE INTERFACE FOR SENSOR SYSTEMS FABRICATED BY CMOS TECHNOLOGY WITH POST-PROCESSING
    LEME, CA
    BALTES, H