Comparative analysis of different impression techniques in relation to single tooth impression

被引:65
|
作者
Merchant, Aman [1 ]
Maiti, Subhabrata [1 ]
Ashok, V [1 ]
Ganapathy, Dhanraj M. [1 ]
机构
[1] Saveetha Univ Chennai, Saveetha Dent Coll & Hosp, Saveetha Inst Med & Tech Sci, Chennai, Tamil Nadu, India
关键词
Accuracy; Dimensional Stability; Impressions; ONE-STEP; DIMENSIONAL ACCURACY; 2-STEP; CASTS; MONOPHASE;
D O I
10.6026/973206300161105
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
It is of interest to compare the accuracy of three different impression techniques for a single tooth impression. We used 3 groups with 15 samples each in this study. Group 1: Putty and light body in a sectional stock tray; Group 2: Monophase and extra light body in a sectional stock tray; Group 3: Matrix impression technique. 15 impressions were taken of a prepared tooth on a typodont with each technique. The dimensions of the casts poured from these impression techniques were compared with the control typodont tooth. Data analysis shows that the matrix impression technique gave the best results in terms of dimensional study followed by monophase and extra light body impression technique and putty and light body impression technique gave the least accurate results. The results show that there is a statistically significant difference between the three impression techniques in terms of dimensional stability. Data analysis shows that the matrix impression technique gave the best results in terms of dimensional study followed by monophase and extra light body impression technique and putty and light body impression technique gave the least accurate results. The variations between the groups are within acceptable limits. Hence, it can be concluded that all the impression techniques will result in adequate dimensional stability and can be used in clinical scenarios.
引用
收藏
页码:1105 / 1112
页数:8
相关论文
共 50 条
  • [21] A COMPARATIVE-ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN-GAUGE
    HAN, ET
    KIM, YS
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 995 - 995
  • [22] Implant Impression Techniques using Different Materials and Methods: A Review
    Yasar, Muhammed Necati
    Cetinsahin, Cem
    Bayar, Omer
    Ozer, Hasan Yildrim
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (02) : ZE12 - ZE17
  • [23] Effect of different retraction and impression techniques on the marginal fit of crowns
    Woestmann, Bernd
    Rehmann, Peter
    Trost, Dieter
    Balkenhol, Markus
    JOURNAL OF DENTISTRY, 2008, 36 (07) : 508 - 512
  • [24] IMPRESSION TECHNIQUES FOR PREPARATIONS WITH SHOULDERS
    ABARNO, JC
    SPATAKIS, S
    JOURNAL OF PROSTHETIC DENTISTRY, 1984, 51 (01): : 42 - 45
  • [25] Comparison of the Accuracy of Different Transfer Impression Techniques for Osseointegrated Implants
    Zen, Bruno Massucato
    Soares, Eveline Freitas
    Rodrigues, Mariana Agustinho
    Luthi, Leonardo Flores
    Consani, Rafael Leonardo X.
    Mesquita, Marcelo Ferraz
    Pessanha Henriques, Guilherme Elias
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 662 - 667
  • [26] Comparison of different impression techniques for edentulous jaws using three-dimensional analysis
    Jung, Sua
    Park, Chan
    Yang, Hong-So
    Lim, Hyun-Pil
    Yun, Kwi-Dug
    Ying, Zhai
    Park, Sang-Won
    JOURNAL OF ADVANCED PROSTHODONTICS, 2019, 11 (03): : 179 - 186
  • [27] Impression techniques for implant dentistry
    Chee, W.
    Jivraj, S.
    BRITISH DENTAL JOURNAL, 2006, 201 (07) : 429 - 432
  • [28] DISPLACEMENT CHARACTERISTICS OF IMPRESSION TECHNIQUES
    GOOLAMMIA, R
    WILDING, RJC
    ADAMS, LP
    JOURNAL OF DENTAL RESEARCH, 1988, 67 (04) : 785 - 785
  • [29] Evaluation of the accuracy of different transfer impression techniques for multiple implants
    Brigolini de Faria, Julio Cesar
    Silva-Concilio, Lais Regiane
    Claro Neves, Ana Christina
    Miranda, Milton Edson
    Teixeira, Marcelo Lucchesi
    BRAZILIAN ORAL RESEARCH, 2011, 25 (02) : 163 - 167
  • [30] Accuracy of Different Impression Techniques for Internal-Connection Implants
    Lee, Yun-Jung
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 823 - 830