Retrospective Analysis of Synthetic Cannabinoid Metabolites in Urine of Individuals Suspected of Driving Impaired

被引:15
|
作者
Davies, Bronwen B. [1 ]
Bayard, Ciena [2 ]
Larson, Scott J. [3 ]
Zarwell, Lucas W. [2 ]
Mitchell, Roger A. [2 ]
机构
[1] George Washington Univ, Dept Forens Sci, 2100 Foxhall Rd NW, Washington, DC USA
[2] Off Chief Med Examiner, 401 E St SW, Washington, DC USA
[3] Montana Dept Justice, Forens Sci Div, 2679 Palmer St, Missoula, MT 59808 USA
关键词
TANDEM MASS-SPECTROMETRY; JWH-018; QUANTIFICATION; VALIDATION; SAMPLES; MS; EPIDEMIOLOGY; PREVALENCE; XLR-11; DRUGS;
D O I
10.1093/jat/bkv136
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Identification and analysis of synthetic cannabinoids (SCs) in biological specimens remains an ongoing challenge for forensic toxicologists. Analytical method development is both resource and time consuming, and falls behind the illicit production of newer SCs. Distinguishing optimal metabolic targets and specific SC use is further complicated by metabolic pathway convergence between different SCs. Gaining further insight into the prevalence and psychopharmacologic role of these drugs in forensic cases, particularly in individuals suspected of driving impaired, is important. The prevalence of SC metabolites (SCMs) in suspects of impaired driving in Washington, DC between June 2012 and August 2013 was studied. A total of 526 urine sampleswere screened for 12 SCMs by liquid chromatography tandem mass spectrometry in separate duplicate analyses. Nineteen cases (3.6%) confirmed positive for the following SCMs: UR-144 N-pentanoic acid (n = 17; 89%), JWH-073 butanoic acid (n = 3; 16%), JWH-018 pentanoic acid (n = 3; 16%), AM-2201 4-hydroxypentyl (n = 3; 16%) and 5fluoro PB22 3-carboxyindole (n = 1; 5%). This study made use of existing analytical methodology to provide insight into the prevalence of synthetic cannabinoid use in DUID cases. Understanding the range and extent of use in these cases can provide valuable information to the forensic
引用
收藏
页码:89 / 96
页数:8
相关论文
共 32 条
  • [21] Detection of metabolites of the new synthetic cannabinoid CUMYL-4CN-BINACA in authentic urine samples and human liver microsomes using high-resolution mass spectrometry
    Ozturk, Yeter Erol
    Yeter, Oya
    Ozturk, Serkan
    Karakus, Goksun
    Ates, Ismail
    Buyuk, Yalcin
    Yurdun, Turkan
    DRUG TESTING AND ANALYSIS, 2018, 10 (03) : 449 - 459
  • [22] Long-term stability of 24 synthetic cannabinoid metabolites spiked into whole blood and urine for up to 168 days, and the comparable study for the 6 metabolites in non-spiked real case specimens stored for  1–5 years
    Kayoko Minakata
    Koutaro Hasegawa
    Hideki Nozawa
    Itaru Yamagishi
    Naotomo Miyoshi
    Masako Suzuki
    Takuya Kitamoto
    Minako Kondo
    Kanako Watanabe
    Osamu Suzuki
    Forensic Toxicology, 2022, 40 : 289 - 301
  • [23] Metabolites of 5F-AKB-48, a synthetic cannabinoid receptor agonist, identified in human urine and liver microsomal preparations using liquid chromatography high-resolution mass spectrometry
    Holm, Niels Bjerre
    Pedersen, Anders Just
    Dalsgaard, Petur Weihe
    Linnet, Kristian
    DRUG TESTING AND ANALYSIS, 2015, 7 (03) : 199 - 206
  • [24] Long-term stability of 24 synthetic cannabinoid metabolites spiked into whole blood and urine for up to 168 days, and the comparable study for the 6 metabolites in non-spiked real case specimens stored for 1-5 years
    Minakata, Kayoko
    Hasegawa, Koutaro
    Nozawa, Hideki
    Yamagishi, Itaru
    Miyoshi, Naotomo
    Suzuki, Masako
    Kitamoto, Takuya
    Kondo, Minako
    Watanabe, Kanako
    Suzuki, Osamu
    FORENSIC TOXICOLOGY, 2022, 40 (02) : 289 - 301
  • [25] The analysis of the reduction in vehicle speech intelligibility for normal hearing and hearing impaired individuals in a simulated driving environment with contributions from the ordered and masking noise sources
    Department of Mechanical, Automotive and Materials Engineering, University of Windsor, Windsor, ON, N9B 3P4, Canada
    1600, Audio Engineering Society (61):
  • [26] The Analysis of the Reduction in Vehicle Speech Intelligibility for Normal Hearing and Hearing Impaired Individuals in a Simulated Driving Environment with Contributions from the Ordered and Masking Noise Sources
    Samardzic, Nikolina
    Novak, Colin
    JOURNAL OF THE AUDIO ENGINEERING SOCIETY, 2013, 61 (09): : 676 - 687
  • [27] Analysis of tamoxifen and its metabolites in synthetic gastric fluid digests and urine samples using high-performance liquid chromatography with electrospray mass spectrometry
    Li, XF
    Carter, S
    Dovichi, NJ
    Zhao, JY
    Kovarik, P
    Sakuma, T
    JOURNAL OF CHROMATOGRAPHY A, 2001, 914 (1-2) : 5 - 12
  • [28] Ambient Fail exception messages during breath testing of suspected impaired drivers using the Intoxilyzer((R)) 5000C: a 10-year retrospective analysis
    Palmentier, J-P.
    Langille, R.
    House, C.
    Patrick, J.
    CANADIAN SOCIETY OF FORENSIC SCIENCE JOURNAL, 2015, 48 (01) : 46 - 57
  • [29] Radio Frequency Interference messages during breath testing of suspected impaired drivers using the Intoxilyzer (R) 5000C: A 13-year retrospective analysis
    Palmentier, Jean-Paul F. P.
    Woodall, Karen L.
    Savoia, Carlo
    CANADIAN SOCIETY OF FORENSIC SCIENCE JOURNAL, 2016, 49 (03) : 127 - 137
  • [30] Frequency Interference messages during breath testing of suspected impaired drivers using the Intoxilyzer (c) 5000C: A 13-year retrospective analysis (vol 49, pg 127, 2016)
    Palmentier, J-P F. P.
    Woodall, K. L.
    Savoia, C.