Intraocular pressure adjusted for central corneal thickness as a screening tool for open-angle glaucoma in an at-risk population

被引:7
|
作者
de Saint Sardos, A.
Fansi, Kamdeu
Chagnon, M. [2 ]
Harasymowycz, P. J. [1 ]
机构
[1] Univ Montreal, Hop Maison Neuve Rosemont, Dept Ophthalmol, Ophthalmol Res Unit, Montreal, PQ H1T 2M4, Canada
[2] Univ Montreal, Dept Math & Stat, Montreal, PQ H1T 2M4, Canada
关键词
CCT; IOP; glaucoma screening; OCULAR HYPERTENSION TREATMENT; BALTIMORE EYE SURVEY; APPLANATION TONOMETRY; VISUAL-FIELD; PROGRESSION; WORLDWIDE; VALIDITY; PEOPLE; NUMBER; DAMAGE;
D O I
10.3129/i09-129
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: Evaluation of intraocular pressure (IOP) adjusted for central corneal thickness (CCT) screening for open-angle glaucoma (OAG) in an at-risk population. Study Design: Community-based screening clinic. Participants: Three hundred and forty-nine persons of black race, or >50 years of age, or with a positive family history of glaucoma. Methods: Ophthalmological examination including Goldmann applanation tonometry, ultrasonographic corneal pachymetry, and visual field testing. Glaucomatous optic nerve damage with visual field loss was the gold standard. IOP was adjusted for CCT based on 3 nomograms. Results were compared with screening using unadjusted IOP. Outcome measures included sensitivity, specificity, areas under the receiver operating characteristic (ROC) curves, positive and negative predictive values (PPVs and NPVs), as well as positive and negative likelihood ratios. Results: No significant difference in CCT was found between those with glaucoma (560 [SD 37] mu m, n = 31) and those without (557 [SD 35] mu m, n = 233). Screening adjusted IOPs for glaucoma with an IOP > 21 mm Hg resulted in PPVs of 23.8% to 25% and NPVs of 89.3% to 89.6%, similar to preadjustment values. Areas under the ROC curves varied from 0.544 to 0.571 post adjustment from the initial value of 0.574. Conclusions: IOP adjusted for CCT is unlikely to improve tonometry as a screening tool for OAG in an at-risk population.
引用
收藏
页码:571 / 575
页数:5
相关论文
共 50 条
  • [41] Comparative results of central corneal thickness measurements in primary open-angle glaucoma, pseudoexfoliation glaucoma, and ocular hypertension
    Gorezis, Spiridon
    Christos, Gartzos
    Stefaniotou, Maria
    Moustaklis, Kostantinos
    Skyrlas, Aggelos
    Kitsos, Georgios
    OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (01) : 17 - 21
  • [42] Central Corneal Thickness in Patients With Exfoliation Syndrome, Exfoliative Glaucoma, Primary Open-Angle Glaucoma and Ocular Hypertention
    Mikropoulos, D. G.
    Economou, A. I.
    Kaltsos, K.
    Boboridis, K.
    Dimopoulos, A. T.
    Georgiadou, I.
    Nasr, M. B.
    Ziakas, N.
    Konstas, A. G. P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [43] Association between corneal thickness, intraocular pressure, and disease stability in Primary Open Angle glaucoma
    Walker, JH
    Buys, Y
    Trope, GE
    Vicente, C
    Einarson, TR
    Covert, D
    Isekedjian, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U455 - U455
  • [44] Risk Factors for Progression of Primary Open-Angle Glaucoma with Lower Normal Intraocular Pressure
    Ueda, Yuta
    Suda, Kenji
    Kameda, Takanori
    Ikeda, Hanako Ohashi
    Miyake, Masahiro
    Hasegawa, Tomoko
    Numa, Shogo
    Tsujikawa, Akitaka
    OPHTHALMIC RESEARCH, 2024, 67 (01) : 184 - 191
  • [45] Interocular Asymmetry of Visual Field Loss, Intraocular Pressure, and Corneal Parameters in Primary Open-Angle Glaucoma
    Jiang, Jun Hong
    Pan, Xia Fei
    Lin, Zhong
    Moonasar, Nived
    Ye, Cong
    Zhang, Shao Dan
    Feng, Ke Mi
    Liang, Yuan Bo
    OPHTHALMIC RESEARCH, 2021, 64 (05) : 857 - 862
  • [46] Diurnal intraocular pressure fluctuation and its risk factors in angle-closure and open-angle glaucoma
    S Srinivasan
    N S Choudhari
    M Baskaran
    R J George
    B Shantha
    L Vijaya
    Eye, 2016, 30 : 362 - 368
  • [47] Diurnal intraocular pressure fluctuation and its risk factors in angle-closure and open-angle glaucoma
    Srinivasan, S.
    Choudhari, N. S.
    Baskaran, M.
    George, R. J.
    Shantha, B.
    Vijaya, L.
    EYE, 2016, 30 (03) : 362 - 368
  • [48] Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma
    Copt, RP
    Thomas, R
    Mermoud, A
    ARCHIVES OF OPHTHALMOLOGY, 1999, 117 (01) : 14 - 16
  • [49] Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls
    Vinciguerra, Riccardo
    Rehman, Salwah
    Vallabh, Neeru A.
    Batterbury, Mark
    Czanner, Gabriela
    Choudhary, Anshoo
    Cheeseman, Robert
    Elsheikh, Ahmed
    Willoughby, Colin E.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (01) : 121 - 126
  • [50] Central corneal thickness and intraocular pressure in a Mongolian population
    Foster, PJ
    Baasanhu, J
    Alsbirk, PH
    Munkhbayar, D
    Uranchimeg, D
    Johnson, GJ
    OPHTHALMOLOGY, 1998, 105 (06) : 969 - 973