The Solid Phase Extraction of Lead Using Silver Nanoparticles-Attached to Silica Gel Prior to its Determination by FAAS

被引:27
|
作者
Baysal, Asli [1 ]
Kahraman, Mehmet [2 ]
Akman, Suleyman [1 ]
机构
[1] Istanbul Tech Univ, Dept Chem, Fac Arts & Sci, TR-80626 Istanbul, Turkey
[2] Yeditepe Univ, Dept Genet & Bioengn, Fac Engn & Architecture, Istanbul, Turkey
关键词
Silica gel; Lead; Nano sized silver; Atomic absorption spectrometry; ATOMIC-ABSORPTION-SPECTROMETRY; MULTIWALLED CARBON NANOTUBES; ICP-AES; PRECONCENTRATION; SEPARATION; ENRICHMENT; WATER; DIOXIDE; COPPER; IONS;
D O I
10.2174/157341109789077740
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nano-silver coated silica gel was impregnated with ammonium pyrrolidine-dithiocarbamate (APDC) and used for the separation and preconcentration of lead prior to its determination by flame atomic absorption spectrometry. The silver coated silica gel was prepared by mixing slurried silica gel with solid silver nitrate and sodium boron hydride. The silver coated silica gel was then impregnated with ammonium pyrrolidine-dithiocarbamate. For enrichment/separation of the analyte, as an alternative to the conventional column technique, the housing of a syringe-mountable filter was filled with the sorbent and mounted to the tip of a 50 mL of syringe. In order to retain the analytes, the sample solution was drawn into the syringe and ejected back again by passing through the sorbent in the filter. The analyte on the sorbent was then eluted by drawing and ejected back an eluent. The effects of experimental conditions with regards to the amount of sorbent, pH of sample, concentration and kind of eluent, foreign ions, flow rates of sample and eluent on the recovery (retention and elution) of the analyte were investigated. All quantifications were performed with a flame atomic absorption spectrophotometer. The analyte was quantitatively retained at pH >= 7 and eluted with 3.0 M of HNO3 applying a 20 mL min(-1) of drawing and discharging rates (flow rates) for sorption and elution steps with less than 10% of RSD. In order to increase the sample volume and thereby concentration factor, several portions of sample were successively drawn and ejected back through the sorbent but eluted only once. The limit of detection of the method for lead was 0.36 ng mL(-1) according to 3 sigma criteria (N=10). The validation of the proposed method was tested by using waste water certified reference materials and quantitative recoveries in the range of 95% confidence level were obtained. Finally, the presented method was used for the determination of lead in real water samples. The sorbent prepared is novel and its use in syringe mountable filter for enrichment/separation is challenging.
引用
收藏
页码:352 / 357
页数:6
相关论文
共 50 条
  • [31] Solid phase extraction of lead and cadmium using solid sulfur as a new metal extractor prior to determination by flame atomic absorption spectrometry
    Parham, H.
    Pourreza, N.
    Rahbar, N.
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 163 (2-3) : 588 - 592
  • [32] Silver Nanoparticles as a New Solid-Phase Adsorbent and Its Application to Preconcentration and Determination of Lead from Biological Samples
    Mostafa Khajeh
    Esmael Sanchooli
    Biological Trace Element Research, 2011, 143 : 1856 - 1864
  • [33] Silver Nanoparticles as a New Solid-Phase Adsorbent and Its Application to Preconcentration and Determination of Lead from Biological Samples
    Khajeh, Mostafa
    Sanchooli, Esmael
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2011, 143 (03) : 1856 - 1864
  • [34] Silica-coated Mn3O4 nanoparticles coated with an ionic liquid for use in solid phase extraction of silver(I) ions prior to their determination by AAS
    Abdolmohammad-Zadeh, Hossein
    Javan, Zahra
    MICROCHIMICA ACTA, 2015, 182 (7-8) : 1447 - 1456
  • [35] Silica-coated Mn3O4 nanoparticles coated with an ionic liquid for use in solid phase extraction of silver(I) ions prior to their determination by AAS
    Hossein Abdolmohammad-Zadeh
    Zahra Javan
    Microchimica Acta, 2015, 182 : 1447 - 1456
  • [36] Continuous flow system for lead determination by faas in spirituous beverages with solid phase extraction and on-line copper removal
    de Peña, YP
    Paredes, B
    Rondón, W
    Burguera, M
    Burguera, JL
    Rondón, C
    Carrero, P
    Capote, T
    TALANTA, 2004, 64 (05) : 1351 - 1358
  • [37] Preparation of dendrimer-like polyamidoamine immobilized silica gel and its application to online preconcentration and separation palladium prior to FAAS determination
    Wu, XZ
    Liu, P
    Pu, QS
    Sun, QY
    Su, ZX
    TALANTA, 2004, 62 (05) : 918 - 923
  • [38] Highly selective determination of rhodium(III) using silica gel surface-imprinted solid-phase extraction
    Zheng, Hong
    Yang, Shuling
    Wang, Jianchao
    Sun, Wenfeng
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (11) : 1013 - 1023
  • [39] Chemically functionalized silica gel with alizarin violet and its application for selective solid-phase extraction of lead from environmental samples
    Fan, Jing
    Wu, Chunlai
    Xu, Haizhu
    Wang, Jianji
    Peng, Chuanyun
    TALANTA, 2008, 74 (04) : 1020 - 1025
  • [40] Ligandless temperature-controlled ionic liquid-phase microextraction of lead(II) ion prior to its determination by FAAS
    Zeid A. Alothman
    Erkan Yilmaz
    Mohamed Habila
    Azza Shabaka
    Mustafa Soylak
    Microchimica Acta, 2013, 180 : 669 - 674