A model for the design and evaluation of algorithms for closed-loop cardiovascular therapy

被引:15
|
作者
Woodruff, EA
Martin, JF
Omens, M
机构
[1] JOHNSON & JOHNSON CONSUMER PROD INC, ETHICON ENDOSURG DIV, CINCINNATI, OH 45242 USA
[2] IVAC MED, SAN DIEGO, CA 92037 USA
关键词
cardiovascular modeling; cardiovascular surgery; closed-loop control system; model reference adaptive controller; self-tuning regulator; simulation;
D O I
10.1109/10.605426
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Developing a clinically useful closed-loop drug delivery system can be extremely time consuming and costly, One approach to reducing the time and cost associated with developing closed-loop systems is to reduce the number of animal experiments and perform an extensive set of simulation studies, Through simulations, a closed-loop controller's performance can be evaluated over a complete spectrum of the patient population, including boundary conditions, Simulation studies are repeatable, offering significant advantages in comparing modifications in control algorithms, Finally, simulation studies can be performed in a fraction of the time required for animal studies, at a fraction of the cost, me have developed a simulator, that included a nonlinear pulsatile-flow cardiovascular model, a physiological regulatory mechanism, and the pharmacology of four frequently titrated cardiovascular drugs, This simulator has already been used in the design and evaluation of two closed-loop algorithms-a self-tuning regulator (STR) and a multiple model adaptive controller (MMAC)-for blood pressure control during and after cardiac surgery.
引用
收藏
页码:694 / 705
页数:12
相关论文
共 50 条
  • [31] Network design model for remanufacturing closed-loop supply chain competition
    Yang, Yuxiang
    Tang, Yibing
    Wu, Zengyuan
    Hu, Chenxia
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2014, 50 (20): : 205 - 212
  • [32] A robust optimization model for the design of a cardboard closed-loop supply chain
    Safaei, Abdul Sattar
    Roozbeh, Azadeh
    Paydar, Mohammad Mandi
    JOURNAL OF CLEANER PRODUCTION, 2017, 166 : 1154 - 1168
  • [33] Optimization Design of Closed-loop Supply Chain Based on MILP Model
    Zhang Peilin
    Yang Long
    Yin Ling
    2010 THE 3RD INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND INDUSTRIAL APPLICATION (PACIIA2010), VOL II, 2010, : 25 - 28
  • [34] Optimal closed-loop identification test design for internal model control
    Zhu, YC
    van den Bosch, PPJ
    AUTOMATICA, 2000, 36 (08) : 1237 - 1241
  • [35] Design of Closed-Loop Supply Chain Model with Efficient Operation Strategy
    Chen, Xing
    Chuluunsukh, Anudari
    Yun, YoungSu
    Gen, Mitsuo
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL CONFERENCE ON MANAGEMENT SCIENCE AND ENGINEERING MANAGEMENT, 2018, : 962 - 974
  • [36] A Dynamic Model for Facility Location in Closed-Loop Supply Chain Design
    Joochim, Orapadee
    OPERATIONS RESEARCH PROCEEDINGS 2012, 2014, : 541 - 547
  • [37] Design and Analysis of Closed-Loop Decoder Adaptation Algorithms for Brain-Machine Interfaces
    Dangi, Siddharth
    Orsborn, Amy L.
    Moorman, Helene G.
    Carmena, Jose M.
    NEURAL COMPUTATION, 2013, 25 (07) : 1693 - 1731
  • [38] CADCS SIMULATION OF THE CLOSED-LOOP CARDIOVASCULAR-SYSTEM
    AVANZOLINI, G
    BARBINI, P
    CAPPELLO, A
    CEVENINI, G
    INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1988, 22 (01): : 39 - 49
  • [39] Modeling and Analysis of Closed-Loop Control of the Cardiovascular System
    Gee, Michelle
    Hornung, Eden
    Moss, Alison
    Kuttippurathu, Lakshmi
    Schwaber, James S.
    Ogunnaike, Babatunde
    Vadigepalli, Rajanikanth
    FASEB JOURNAL, 2022, 36
  • [40] Effects of CPAP therapy on cardiovascular variability in obstructive sleep apnea: a closed-loop analysis
    Belozeroff, V
    Berry, RB
    Sassoon, CSH
    Khoo, MCK
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2002, 282 (01): : H110 - H121