Capacitor-Current Proportional-Integral Positive Feedback Active Damping for LCL-Type Grid-Connected Inverter to Achieve High Robustness Against Grid Impedance Variation

被引:112
|
作者
He, Yuying [1 ]
Wang, Xuehua [1 ]
Ruan, Xinbo [1 ,2 ]
Pan, Donghua [1 ]
Xu, Xingping [1 ]
Liu, Fuxin [2 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Aeropower Sci Tech, Nanjing 211106, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Active damping; control delays; grid impedance; LCL filter; robustness; TIME-DELAY COMPENSATION; CONTROLLER-DESIGN; DIGITAL-CONTROL; STABILITY; FILTER; REALIZATION; PERFORMANCE; VSCS;
D O I
10.1109/TPEL.2019.2906217
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Capacitor-current-feedback active damping has been widely used in LCL-type grid-connected inverters. However, the damping performance is deteriorated due to the negative equivalent resistance resulted by the digital control delays, and thus the grid-connected inverter is apt to be unstable under the grid impedance variation. To address this issue, this paper proposes the capacitor-current proportional-integral (PI) positive feedback active damping method that can ensure a positive equivalent resistance almost within the Nyquist frequency, i.e., the full controllable frequency range. In theory, the proposed damping method can be implemented by feeding back the capacitor current through a PI function. However, the integral term will continuously accumulate the noise and dc bias arising from the feedback signal. To overcome this drawback, a more practical implementation solution is drawn in this paper. Furthermore, a straightforward design procedure is presented for the convenience of selecting the proper controller parameters. With the proposed damping method and its practical implementation, high inverter robustness against the grid impedance variation can be achieved. Experiments are performed on a 6-kW prototype and the experimental results are in well agreement with the theoretical expectations.
引用
收藏
页码:12423 / 12436
页数:14
相关论文
共 50 条
  • [21] Systematic controller design for digitally controlled LCL-type grid-connected inverter with grid-current-feedback active damping
    Zhu, Donghai
    Zou, Xudong
    Zhao, Yingying
    Peng, Teng
    Zhou, Shiying
    Kang, Yong
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 110 : 642 - 652
  • [22] Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping
    Bao, Chenlei
    Ruan, Xinbo
    Wang, Xuehua
    Li, Weiwei
    Pan, Donghua
    Weng, Kailei
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) : 1239 - 1253
  • [23] Hybrid Active Damping Combining Capacitor Current Feedback and Point of Common Coupling Voltage Feedforward for LCL-Type Grid-Connected Inverter
    He, Yuying
    Wang, Xuehua
    Ruan, Xinbo
    Pan, Donghua
    Qin, Kuang
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (02) : 2373 - 2383
  • [24] Optimized design method for grid-current-feedback active damping to improve dynamic characteristic of LCL-type grid-connected inverter
    Chen, Yandong
    Xie, Zhiwei
    Zhou, Leming
    Wang, Zili
    Zhou, Xiaoping
    Wu, Wenhua
    Yang, Ling
    Luo, An
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 100 : 19 - 28
  • [25] Unified Active Damping Strategy Based on Generalized Virtual Impedance in LCL-Type Grid-Connected Inverter
    Chen, Wei
    Zhang, Yan
    Tu, Yiming
    Guan, Yuanpeng
    Shen, Ke
    Liu, Jinjun
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (08) : 8129 - 8139
  • [26] Grid-Current Control With Inverter-Current Feedback Active Damping for LCL Grid-Connected Inverter
    Upadhyay, Nitin
    Padhy, Narayana Prasad
    Agarwal, Pramod
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (01) : 1738 - 1749
  • [27] An Adaptive Proportional Feedforward Scheme for LCL-Type Grid-Connected Inverter
    Qin, Kuang
    Wang, Wentao
    Wang, Xuehua
    He, Yuying
    Ruan, Xinbo
    Liu, Fuxin
    2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 3287 - 3292
  • [28] Design and implementation of an LCL grid-connected inverter based on capacitive current fractional proportional-integral feedback strategy
    Wang, Qingyi
    Ju, Binlei
    Zhang, Yiqiong
    Zhou, Dan
    Wang, Nan
    Wu, Genping
    IET CONTROL THEORY AND APPLICATIONS, 2020, 14 (18): : 2889 - 2899
  • [29] A resonant damping control and analysis for LCL-type grid-connected inverter
    Khan, Danish
    Hu, Pengfei
    Habib, Salman
    Waseem, Muhammad
    Lin, Zhenzhi
    Ahmed, Emad M.
    ENERGY REPORTS, 2022, 8 : 911 - 928
  • [30] Robust Grid-Current-Feedback Resonance Suppression Method for LCL-Type Grid-Connected Inverter Connected to Weak Grid
    Zhou, Xiaoping
    Zhou, Leming
    Chen, Yandong
    Shuai, Zhikang
    Guerrero, Josep M.
    Luo, An
    Wu, Wenhua
    Yang, Ling
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2018, 6 (04) : 2126 - 2137