Capacitor-Current Proportional-Integral Positive Feedback Active Damping for LCL-Type Grid-Connected Inverter to Achieve High Robustness Against Grid Impedance Variation

被引:112
|
作者
He, Yuying [1 ]
Wang, Xuehua [1 ]
Ruan, Xinbo [1 ,2 ]
Pan, Donghua [1 ]
Xu, Xingping [1 ]
Liu, Fuxin [2 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Aeropower Sci Tech, Nanjing 211106, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Active damping; control delays; grid impedance; LCL filter; robustness; TIME-DELAY COMPENSATION; CONTROLLER-DESIGN; DIGITAL-CONTROL; STABILITY; FILTER; REALIZATION; PERFORMANCE; VSCS;
D O I
10.1109/TPEL.2019.2906217
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Capacitor-current-feedback active damping has been widely used in LCL-type grid-connected inverters. However, the damping performance is deteriorated due to the negative equivalent resistance resulted by the digital control delays, and thus the grid-connected inverter is apt to be unstable under the grid impedance variation. To address this issue, this paper proposes the capacitor-current proportional-integral (PI) positive feedback active damping method that can ensure a positive equivalent resistance almost within the Nyquist frequency, i.e., the full controllable frequency range. In theory, the proposed damping method can be implemented by feeding back the capacitor current through a PI function. However, the integral term will continuously accumulate the noise and dc bias arising from the feedback signal. To overcome this drawback, a more practical implementation solution is drawn in this paper. Furthermore, a straightforward design procedure is presented for the convenience of selecting the proper controller parameters. With the proposed damping method and its practical implementation, high inverter robustness against the grid impedance variation can be achieved. Experiments are performed on a 6-kW prototype and the experimental results are in well agreement with the theoretical expectations.
引用
收藏
页码:12423 / 12436
页数:14
相关论文
共 50 条
  • [1] A Capacitor-Current-Feedback Positive Active Damping Control Strategy for LCL-Type Grid-Connected Inverter to Achieve High Robustness
    Li, Shaojie
    Lin, Hua
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (06) : 6462 - 6474
  • [2] An Active Capacitor Converter for Improving Robustness of the LCL-Type Grid-Connected Inverter against Grid Impedance Variation
    Zhou, Qingfeng
    Wang, Xuehua
    Ruan, Xinbo
    Teng, Yu
    Liu, Fuxin
    2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, : 3608 - 3613
  • [3] A capacitor-current real-time feedback active damping method for improving robustness of the LCL-type grid-connected inverter
    Pan, D. (pan_dh@hust.edu.cn), 1600, Chinese Society for Electrical Engineering (33):
  • [4] High Robustness Grid Current Feedback Active Damping Strategy for LCL-type Grid-connected Inverter in Weak Grid
    Dong G.
    Xu Z.
    Sun P.
    Li Q.
    Chen Y.
    Dianwang Jishu/Power System Technology, 2024, 48 (04): : 1672 - 1680
  • [5] Damping region extension for digitally controlled LCL-type grid-connected inverter with capacitor-current feedback
    Liu, Jinhong
    Zhou, Lin
    Molinas, Marta
    IET POWER ELECTRONICS, 2018, 11 (12) : 1974 - 1982
  • [6] Controller design for LCL-type grid-connected inverter to achieve high robustness against grid-impedance variation
    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science & Technology, Wuhan
    Hubei Province
    430074, China
    Zhongguo Dianji Gongcheng Xuebao, 10 (2558-2566): : 2558 - 2566
  • [7] Robust Capacitor-Current-Feedback Active Damping for the LCL-Type Grid-Connected Inverter
    Pan, Donghua
    Ruan, Xinbo
    Wang, Xuehua
    Bao, Chenlei
    Li, Weiwei
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 728 - 735
  • [8] Optimized Controller Design for LCL-Type Grid-Connected Inverter to Achieve High Robustness Against Grid-Impedance Variation
    Pan, Donghua
    Ruan, Xinbo
    Bao, Chenlei
    Li, Weiwei
    Wang, Xuehua
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (03) : 1537 - 1547
  • [9] Capacitor-Current-Feedback With Improved Delay Compensation for LCL-Type Grid-Connected Inverter to Achieve High Robustness in Weak Grid
    Zhao, Tieying
    Li, Junran
    Gao, Ning
    IEEE ACCESS, 2022, 10 : 127956 - 127968
  • [10] A grid impedance shaping method to improve robustness of LCL-type grid-connected inverter against grid impedance variation
    Teng, Yu
    Wang, Xuehua
    Yu, Hui
    Yin, Qiuyang
    Ruan, Xinbo
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 : 197 - 204