Photoacoustic Imaging with Capacitive Micromachined Ultrasound Transducers: Principles and Developments

被引:30
|
作者
Chan, Jasmine [1 ]
Zheng, Zhou [1 ]
Bell, Kevan [1 ]
Le, Martin [2 ]
Reza, Parsin Haji [1 ]
Yeow, John T. W. [1 ]
机构
[1] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON N2L 3G1, Canada
[2] Univ Waterloo, Dept Phys, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
photoacoustic tomography; capacitive micromachined ultrasound transducer; photoacoustic endoscopy; photoacoustic microscopy; photoacoustic computed tomography; IN-VIVO; HIGH-FREQUENCY; COMPUTED-TOMOGRAPHY; HIGH-RESOLUTION; PIEZOELECTRIC TRANSDUCER; BLOOD OXYGENATION; OPTICAL-DETECTION; CMUT; MICROSCOPY; ARRAYS;
D O I
10.3390/s19163617
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Photoacoustic imaging (PAI) is an emerging imaging technique that bridges the gap between pure optical and acoustic techniques to provide images with optical contrast at the acoustic penetration depth. The two key components that have allowed PAI to attain high-resolution images at deeper penetration depths are the photoacoustic signal generator, which is typically implemented as a pulsed laser and the detector to receive the generated acoustic signals. Many types of acoustic sensors have been explored as a detector for the PAI including Fabry-Perot interferometers (FPIs), micro ring resonators (MRRs), piezoelectric transducers, and capacitive micromachined ultrasound transducers (CMUTs). The fabrication technique of CMUTs has given it an edge over the other detectors. First, CMUTs can be easily fabricated into given shapes and sizes to fit the design specifications. Moreover, they can be made into an array to increase the imaging speed and reduce motion artifacts. With a fabrication technique that is similar to complementary metal-oxide-semiconductor (CMOS), CMUTs can be integrated with electronics to reduce the parasitic capacitance and improve the signal to noise ratio. The numerous benefits of CMUTs have enticed researchers to develop it for various PAI purposes such as photoacoustic computed tomography (PACT) and photoacoustic endoscopy applications. For PACT applications, the main areas of research are in designing two-dimensional array, transparent, and multi-frequency CMUTs. Moving from the table top approach to endoscopes, some of the different configurations that are being investigated are phased and ring arrays. In this paper, an overview of the development of CMUTs for PAI is presented.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] Micromachined capacitive transducers with improved optical detection for ultrasound applications in air
    Hall, NA
    Lee, W
    Dervan, J
    Degertekin, FL
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1027 - 1030
  • [32] Application of Capacitive micromachined ultrasound transducers for detection of specific interaction of materials
    Sapeliauskas, E.
    Barauskas, D.
    Pelenis, D.
    Vanagas, G.
    Mikolajunas, M.
    Virzonis, D.
    11TH INTERNATIONAL CONFERENCE ON INTELLIGENT TECHNOLOGIES IN LOGISTICS AND MECHATRONICS SYSTEMS (ITELMS'2016), 2016, : 141 - 144
  • [33] Modeling and Characterization of CMOS-Fabricated Capacitive Micromachined Ultrasound Transducers
    Doody, Christopher B.
    Cheng, Xiaoyang
    Rich, Collin A.
    Lemmerhirt, David F.
    White, Robert D.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2011, 20 (01) : 104 - 118
  • [34] 3D simulation of controlled micromachined capacitive ultrasound transducers
    Kaltenbacher, M
    Landes, K
    Niederer, K
    Lerch, R
    1999 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 1999, : 1155 - 1158
  • [35] Analysis of Collapse-Snapback Phenomena in Capacitive Micromachined Ultrasound Transducers
    Halbach, Chloe
    Rochus, Veronique
    Genoe, Jan
    Rottenberg, Xavier
    Cheyns, David
    Heremans, Paul
    MICROMACHINES, 2025, 16 (02)
  • [36] 3-D airborne ultrasound synthetic aperture imaging based on capacitive micromachined ultrasonic transducers
    Park, Kwan Kyu
    Khuri-Yakub, Butrus T.
    ULTRASONICS, 2013, 53 (07) : 1355 - 1362
  • [37] A Micromachined Acoustic Multiplexer for Ultrasound and Photoacoustic Imaging Applications
    Chang, Cheng-Chung
    Cho, Young
    Zou, Jun
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2014, 23 (03) : 514 - 516
  • [38] Micromachined capacitive transducer arrays for medical ultrasound imaging
    Jin, XC
    Degertekin, FL
    Calmes, S
    Zhang, XJ
    Ladabaum, I
    Khuri-Yakub, BT
    1998 IEEE ULTRASONICS SYMPOSIUM - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1877 - 1880
  • [39] Capacitive Micromachined Ultrasonic Transducers for forward looking intravascular imaging arrays
    Knight, JG
    Degertekin, FL
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1079 - 1082
  • [40] Gap Feedback Linearization of Capacitive Micromachined Ultrasonic Transducers for Harmonic Imaging
    Satir, Sarp
    Degertekin, F. Levent
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 112 - 115