ANALYSIS OF TEMPERATURE DROPS ON THE WALL THICKNESS OF A SUPERCRITICAL BOILER WATER-WALL TUBE

被引:6
|
作者
Zima, Wieslaw [1 ]
机构
[1] Cracow Univ Technol, Inst Thermal Power Engn, Krakow, Poland
来源
THERMAL SCIENCE | 2019年 / 23卷
关键词
supercritical power boiler; finned water-wall tubes; transient state; control volume method; temperature drops; CONJUGATE HEAT-TRANSFER; SIMULATION;
D O I
10.2298/TSCI19S4091Z
中图分类号
O414.1 [热力学];
学科分类号
摘要
The paper presents selected results of numerical computations related to simulations of a supercritical power boiler evaporator operation. A detailed analysis is carried out of temperature drops on the thickness of the water-wall tube and the tube fin. A comparison is also made between the results obtained at the fin division into one and two control volumes. The tube cross-sections analysed along the tube length and including the fins are divided into 24 control volumes, for which 2-D transient heat conduction equations are formulated. The 1-D equations describing the principles of mass, momentum, and energy conservation are solved on the side of the working fluid. A convective condition, described by an empirical heat transfer coefficient, is set on the water-wall tube inner surface. The developed mathematical model is a distributed parameter model. The numerical computations are performed for a boiler operating in a power plant in Poland. The analysis takes account of the non-uniformity of the furnace chamber thermal load along its height.
引用
收藏
页码:S1091 / S1100
页数:10
相关论文
共 50 条
  • [1] The Temperature of a Water-Wall Tube in a Drum Boiler
    Kholshchev, V.V.
    Thermal Engineering, 1998, 45 (10): : 839 - 841
  • [2] High-temperature Corrosion of Water-wall in Supercritical Boiler
    Pan, Ling
    Ma, Guangyuan
    Cao, Shunan
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY AND ENVIRONMENTAL SCIENCE 2015, 2015, 31 : 1342 - 1346
  • [3] ANALYSIS OF THE REASONS FOR THE LEAKAGE OF A BOILER WATER-WALL TUBE IN A POWER PLANT
    Guo, Ruidong
    Xue, Song
    Yang, Tao
    Liu, Xuedong
    MATERIALI IN TEHNOLOGIJE, 2020, 54 (02): : 221 - 226
  • [4] Analysis of spiral water-wall tube in once-through boiler
    Hsi An Chiao Tung Ta Hsueh, 11 (51-54):
  • [5] Failure analysis of the water-wall tube in KIVCET waste heat boiler
    Li, Jiadong
    Zhou, Ping
    Yu, Gang
    Yan, Hongjie
    Chen, Zhuo
    Song, Guomeng
    Liao, Zhou
    ENGINEERING FAILURE ANALYSIS, 2021, 121
  • [6] The Numerical Calculation of the Temperature Field of Water-wall Tube of the Supercritical Boiler under Near-Critical Condition
    Li Chun-yan
    MATERIALS RESEARCH AND APPLICATIONS, PTS 1-3, 2014, 875-877 : 1876 - 1880
  • [7] A non-equal fragment model of a water-wall in a supercritical boiler
    Wang, Jizhou
    Zhang, Yanping
    Li, Yu
    Huang, Shuhong
    JOURNAL OF THE ENERGY INSTITUTE, 2015, 88 (02) : 143 - 150
  • [8] Research Of The Fins Thickness Based On 600MW Supercritical Boiler Water-wall Cross-Section Temperature Distribution
    Su, Yongjun
    Yang, Junbao
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 384 - 389
  • [9] Failure Investigation of Fire-Side Water-Wall Tube Boiler
    Fatah, M. C.
    Agustiadi, D.
    Pramono, A. W.
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2021, 20 (05): : 242 - 248
  • [10] Failure investigation of a water-wall tube of fossil-fuel fired boiler
    Ranjeeth, R.
    Aditya, D.
    Gautam, Anil
    Singh, S. P.
    Bhattacharya, S.
    ENGINEERING FAILURE ANALYSIS, 2024, 155