Fluoride release from two types of fluoride-containing orthodontic adhesives: Conventional versus resin-modified glass ionomer cements-An in vitro study

被引:9
|
作者
Dziuk, Yasemin [1 ]
Chhatwani, Sachin [1 ]
Mohlhenrich, Stephan C. [1 ]
Tulka, Sabrina [2 ]
Naumova, Ella A. [3 ]
Danesh, Gholamreza [1 ]
机构
[1] Univ Witten Herdecke, Fac Hlth, Dept Orthodont, Witten, Germany
[2] Univ Witten Herdecke, Fac Hlth, Inst Med Biometry & Epidemiol, Witten, Germany
[3] Univ Witten Herdecke, Fac Hlth, Dept Biol & Mat Sci Dent, Witten, Germany
来源
PLOS ONE | 2021年 / 16卷 / 02期
关键词
WHITE-SPOT LESIONS; CONTINUOUS-FLOW SYSTEM; RESTORATIVE MATERIALS; STRENGTH; ABILITY;
D O I
10.1371/journal.pone.0247716
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction Development of white spot lesions (WSLs) during orthodontic treatment is a common risk factor. Fixation of the orthodontic appliances with glass ionomer cements could reduce the prevalence of WSL's due to their fluoride release capacities. The purpose of this study was to evaluate differences of fluoride release properties from resin-modified and conventional glass ionomer cements (GICs). Methods The resin-modified GICs Fuji ORTHO LC (GC Orthodontics), Meron Plus QM (VOCO), as well as the conventional GICs Fuji ORTHO (GC Orthodontics), Meron (VOCO) and Ketac Cem Easymix (3M ESPE) were tested in this study. The different types of GICs were applied to hydroxyapatite discs according to the manufacturer's instructions and stored in a solution of TISAB III (Total Ionic Strength Adjustment Buffer III) and fluoride-free water at 37 degrees C. Fluoride measurements were made after 5 minutes, 2 hours, 24 hours, 14 days, 28 days, 2 months, 3 months and 6 months. One factor analysis of variance (ANOVA) was used for the overall comparison of the cumulative fluoride release (from measurement times of 5 minutes to 6 months) between the different materials with the overall level of significance set to 0.05. Tukey's post hoc test was used for post hoc pairwise comparisons in the cumulative fluoride release between the different materials. Results The cumulative fluoride release (mean +/- sd) in descending order was: Fuji ORTHO LC (221.7 +/- 10.29 ppm), Fuji ORTHO (191.5 +/- 15.03 ppm), Meron Plus QM (173.0 +/- 5.89 ppm), Meron (161.3 +/- 7.84 ppm) and Ketac Cem Easymix (154.6 +/- 6.09 ppm) within 6 months. Analysis of variance detected a significant difference in the cumulative fluoride release between at least two of the materials (rounded p-value < 0.001). Pairwise analysis with Tukey's post hoc test showed a significant difference in the cumulative fluoride release for all the comparisons except M and MPQM (p = 0.061) and KCE and M (p = 0.517). Conclusion Fluoride ions were released cumulatively over the entire test period for all products. When comparing the two products from the same company (Fuji ORTHO LC vs. Fuji ORTHO from GC Orthodontics Europe GmbH and Meron Plus QM vs. Meron from VOCO GmbH, Mannheim, Germany), it can be said that the resin-modified GICs have a higher release than conventional GICs. The highest individual fluoride release of all GICs was at 24 hours. A general statement, whether resin-modified or conventional GICs have a higher release of fluoride cannot be made.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Fluoride release from glass ionomer cements in vitro in a 90 days study
    Baietti, AM
    Checchi, L
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 174 - 174
  • [32] Effect of home-use fluoride gels on resin-modified glass-ionomer cements
    El-Badrawy, WA
    McComb, D
    OPERATIVE DENTISTRY, 1998, 23 (01) : 2 - 9
  • [33] Fluoride release from a polyacid-modified resin composite and 3 resin-modified glass-ionomer materials
    Yip, HK
    Smales, RJ
    QUINTESSENCE INTERNATIONAL, 2000, 31 (04): : 261 - 266
  • [34] Effect of fluoride gels on micromorphology of resin-modified glass-ionomer cements and polyacid-modified resin composites
    Turssi, CP
    de Magalhaes, CS
    Serra, MC
    QUINTESSENCE INTERNATIONAL, 2001, 32 (07): : 571 - 577
  • [35] Fluoride release from glass-ionomer cements, compomers and resin composites
    Vermeersch, G
    Leloup, G
    Vreven, J
    JOURNAL OF ORAL REHABILITATION, 2001, 28 (01) : 26 - 32
  • [36] An in vitro study of fluoride release from a resin-modified glass ionomer cement after exposure to toothpaste slurries of different pH.
    Olsson C.
    Emilson C.G.
    Birkhed D.
    Clinical Oral Investigations, 2000, 4 (4) : 233 - 237
  • [37] Microhardness of in vitro caries inhibition zone adjacent to conventional and resin-modified glass ionomer cements
    Pereira, PNR
    Inokoshi, S
    Yamada, T
    Tagami, J
    DENTAL MATERIALS, 1998, 14 (03) : 179 - 185
  • [38] The influence of light-curing time on fluoride release, surface topography, and bacterial adhesion in resin-modified glass ionomer cements: AFM and SEM in vitro study
    Olmos-Olmos, Gabriela
    Teutle-Coyotecatl, Bernardo
    Roman-Mendez, Cristian D.
    Carrasco-Gutierrez, Rosendo
    Gonzalez-Torres, Maykel
    Contreras-Bulnes, Rosalia
    Rodriguez-Vilchis, Laura E.
    de los Angeles Moyaho-Bernal, Maria
    MICROSCOPY RESEARCH AND TECHNIQUE, 2021, 84 (08) : 1628 - 1637
  • [39] Fluoride release from an orthodontic glass ionomer adhesive in vitro and enamel fluoride uptake in vivo
    Chatzistavrou, Evangelia
    Eliades, Theodore
    Zinelis, Spiros
    Athanasiou, Athanasios E.
    Eliades, George
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : 458 - 459
  • [40] Fluoride release from conventional glass-ionomer cements and polyacid-modified composite resins
    Yildiz, M
    Bayindir, YZ
    FLUORIDE, 2004, 37 (01) : 38 - 42