Accuracy of Computed Tomographic Angiography for Stenosis Quantification Using Quantitative Coronary Angiography or Intravascular Ultrasound as the Gold Standard

被引:27
|
作者
Joshi, Subodh B. [1 ]
Okabe, Teruo [1 ]
Roswell, Robert O. [1 ]
Weissman, Gaby [1 ]
Lopez, Cristian F. [1 ]
Lindsay, Joseph [1 ]
Pichard, Augusto D. [1 ]
Weissman, Neil J. [1 ]
Waksman, Ron [1 ]
Weigold, Wm Guy [1 ]
机构
[1] Washington Hosp Ctr, Dept Cardiol, Washington, DC 20010 USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2009年 / 104卷 / 08期
关键词
ARTERY STENOSES; DIAGNOSTIC-ACCURACY; NONINVASIVE DETECTION; DISEASE; TECHNOLOGY; CRITERIA; LESIONS;
D O I
10.1016/j.amjcard.2009.05.052
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Computed tomographic angiography (CTA) is considered to have limited accuracy for quantifying exact percent diameter stenosis in coronary arteries. However, most studies evaluating CTA use quantitative coronary angiography (QCA) as the gold standard, a technique with its own limitations. We sought to determine whether CTA measurements of stenosis severity correlate better with intravascular ultrasound (IVUS) than with QCA. Luminal dimensions of 67 de novo coronary lesions were measured by CTA, IVUS, and QCA. IVUS was performed when lesion severity by angiography was equivocal. Mean percent diameter stenosis by QCA was 51 +/- 9.8% and mean IVUS minimal luminal area was 3.8 +/- 1.8 mm(2). There was a moderate correlation between CTA minimal luminal area and IVUS minimal luminal area (r(2) = 0.41, p <0.001), but no relation between CTA and QCA measurements of minimal luminal diameter (r(2) = 0.01, p = 0.57) or diameter stenosis (r(2) = 0.02, p = 0.31). There was also no relation between IVUS minimal luminal area and QCA diameter stenosis (r(2) = 0.01, p = 0.50). When lesions with moderate or severe calcification were excluded, the correlation between CTA minimal luminal area and IVUS minimal luminal area was good (r(2) = 0.68, p <0.001). In conclusion, in this cohort of patients with intermediate-grade lesions on cardiac catheterization, absolute measurements of stenosis severity on CTA correlated with IVUS but not with QCA. Our findings suggest that limitations of quantitative coronary angiography as a gold standard need to be considered in studies evaluating the accuracy of coronary CTA. (C) 2009 Elsevier Inc. All rights reserved. (Am J Cardiol 2009;104:1047-1051)
引用
收藏
页码:1047 / 1051
页数:5
相关论文
共 50 条
  • [21] Diagnostic value of coronary CT angiography in comparison with invasive coronary angiography and intravascular ultrasound in patients with intermediate coronary artery stenosis: results from the prospective multicentre FIGURE-OUT (Functional Imaging criteria for GUiding REview of invasive coronary angiOgraphy, intravascular Ultrasound, and coronary computed Tomographic angiography) study
    Doh, Joon-Hyung
    Koo, Bon-Kwon
    Nam, Chang-Wook
    Kim, Ji-Hyun
    Min, James K.
    Nakazato, Ryo
    Silalahi, Todung
    Prawira, Hardjo
    Choi, Hyunmin
    Lee, Sung Yun
    Namgung, June
    Kwon, Sung Uk
    Kwak, Jae-Jin
    Lee, Won Ro
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (08) : 870 - 877
  • [22] Coronary computed tomographic angiography and invasive coronary angiography: A reevaluation
    Hecht, Harvey S.
    Villines, Todd C.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2020, 14 (04) : 374 - 376
  • [23] Computed tomographic coronary angiography: An alternative to invasive coronary angiography
    Chow, BJW
    Hoffmann, U
    Nieman, K
    CANADIAN JOURNAL OF CARDIOLOGY, 2005, 21 (11) : 933 - 940
  • [24] Quantification of three-dimensional computed tomography angiography for evaluating coronary luminal stenosis using digital subtraction angiography as the standard of reference
    Guo, Wei
    Liu, Xin
    Gao, Zhifan
    Pirbhulal, Sandeep
    Huang, Wenhua
    Lin, Wan-Hua
    Zhang, Heye
    Tan, Ning
    Zhang, Yuan-Ting
    BIOMEDICAL ENGINEERING ONLINE, 2015, 14
  • [26] Quantification of three-dimensional computed tomography angiography for evaluating coronary luminal stenosis using digital subtraction angiography as the standard of reference
    Wei Guo
    Xin Liu
    Zhifan Gao
    Sandeep Pirbhulal
    Wenhua Huang
    Wan-Hua Lin
    Heye Zhang
    Ning Tan
    Yuan-Ting Zhang
    BioMedical Engineering OnLine, 14
  • [27] Functional imaging criteria of non-invasive coronary computed tomographic angiography, invasive coronary angiography and intravascular ultrasound by fractional flow reserve
    Doh, J. H.
    Koo, B. K.
    Nam, C. W.
    Kim, H. S.
    Kim, J. H.
    Lee, S. Y.
    Min, J. K.
    Choe, H.
    EUROPEAN HEART JOURNAL, 2012, 33 : 1012 - 1012
  • [28] Coronary angiography and intravascular ultrasound
    Nissen, S
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (4A): : 15A - 20A
  • [29] Coronary arteries three-dimensional quantification using intravascular ultrasound and angiography
    Leor, OR
    Mauri, J
    Fernandez-Nofrerias, E
    Ayerbe, JL
    Gomez Perez, M
    Tudela, VV
    Rotger, D
    Radeva, P
    EUROPEAN HEART JOURNAL, 2003, 24 : 605 - 605
  • [30] Application of Quantitative Assessment of Coronary Atherosclerosis by Coronary Computed Tomographic Angiography
    Lee, Su Nam
    Lin, Andrew
    Dey, Damini
    Berman, Daniel S.
    Han, Donghee