Influence of cardiac motion on diffusion-weighted magnetic resonance imaging of the liver

被引:110
|
作者
Kwee, Thomas C. [1 ]
Takahara, Taro [1 ]
Niwa, Tetsu [1 ,2 ]
Ivancevic, Marko K. [3 ,4 ]
Herigault, Gwenael [5 ]
Van Cauteren, Marc [6 ]
Luijten, Peter R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Kanagawa Childrens Med Ctr, Dept Radiol, Yokohama, Kanagawa, Japan
[3] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
[4] Philips Healthcare, Cleveland, OH USA
[5] Philips Healthcare, Best, Netherlands
[6] Philips Healthcare Asia Pacific, Tokyo, Japan
关键词
Diffusion-weighted magnetic resonance imaging; DWI; Dynamic; Liver; Cardiac motion; Pseudo-anisotropy artifact; HEPATIC PSEUDO-ANISOTROPY; MRI; SEQUENCES; ARTIFACT; FIBROSIS; LESIONS;
D O I
10.1007/s10334-009-0183-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess cardiac motion-induced signal loss in diffusion-weighted magnetic resonance imaging (DWI) of the liver using dynamic DWI. Three volunteers underwent dynamic coronal DWI of the liver under breathholding, in the diastolic (DWI(diast)) or systolic (DWI(syst)) cardiac phase, and with motion probing gradients (MPGs) in phase encoding (P, left-right), frequency encoding (M, superior-inferior), or slice select (S, anterior-posterior) direction. Liver-to-background contrasts (LBCs) of DWI(syst) were compared to those of DWI(diast), for both the left and right liver lobes, using nonparametric tests. Signal decrease ratios (SDRs) were calculated as (1-(LBCDWI(syst)/LBCDWI(diast))) x 100%. DWI(syst) was further analyzed to determine which direction of MPGs was most affected by cardiac motion. In the left liver lobe, LBCs of DWI(syst) (median 3.35) were significantly lower (P < 0.0001) than those of DWI(diast) (median 4.84). In the right liver lobe, LBCs of DWI(syst) (median 4.17) were also significantly lower (P < 0.0001) than those of DWI(diast) (median 5.35 ). SDRs of the left and right liver lobes were 25.5% and 17.3%, respectively. In DWI(syst), the significantly lowest (P < 0.05) LBCs were observed in the M direction (left liver lobe) and P direction (right liver lobe) of MPGs. Signal intensity of both liver lobes are affected by cardiac motion in DWI. In the left liver lobe, signal loss especially occurs in the superior-inferior direction of MPGs, whereas in the right lobe, signal loss especially occurs in the left-right direction of MPGs.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 50 条
  • [21] Diffusion-weighted imaging in pediatric body magnetic resonance imaging
    Govind B. Chavhan
    Pablo Caro-Dominguez
    Pediatric Radiology, 2016, 46 : 847 - 857
  • [22] Magnetic resonance imaging and diffusion-weighted imaging in methylmalonic acidemia
    Yesildag, A
    Ayata, A
    Baykal, B
    Koroglu, M
    Yildiz, H
    Oral, B
    Oktem, F
    Oyar, O
    ACTA RADIOLOGICA, 2005, 46 (01) : 101 - 103
  • [23] Diffusion-Weighted Magnetic Resonance Imaging of Head and Neck
    Razek, Ahmed Abdel Khalek Abdel
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (06) : 808 - 815
  • [24] Diffusion-Weighted Magnetic Resonance Imaging in Pelvic Cancer
    deSouza, N. M.
    Kyriazi, S.
    Sala, E.
    CURRENT MEDICAL IMAGING REVIEWS, 2012, 8 (02) : 92 - 99
  • [25] Diffusion-weighted magnetic resonance imaging in pituitary abscess
    Takao, H
    Doi, I
    Watanabe, T
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (03) : 514 - 516
  • [26] Diffusion-weighted magnetic resonance imaging in brain death
    Lövblad, KO
    Basssetti, C
    STROKE, 2000, 31 (02) : 539 - 542
  • [27] Diffusion-weighted magnetic resonance imaging in autoimmune pancreatitis
    Takao Taniguchi
    Hisato Kobayashi
    Koji Nishikawa
    Etsushi Iida
    Yoshihiro Michigami
    Emiko Morimoto
    Rikiya Yamashita
    Ken Miyagi
    Motozumi Okamoto
    Japanese Journal of Radiology, 2009, 27 : 138 - 142
  • [28] Diffusion-weighted magnetic resonance imaging of the temporal bone
    B. De Foer
    J-P. Vercruysse
    M. Spaepen
    T. Somers
    M. Pouillon
    E. Offeciers
    J. W. Casselman
    Neuroradiology, 2010, 52 : 785 - 807
  • [29] Diffusion-weighted magnetic resonance imaging in the management of cholesteatoma
    Mudit Jindal
    Jayesh Doshi
    Manoj Srivastav
    David Wilcock
    Richard Irving
    Ranit De
    European Archives of Oto-Rhino-Laryngology, 2010, 267 : 181 - 185
  • [30] Extracranial applications of diffusion-weighted magnetic resonance imaging
    Thoeny, Harriet C.
    De Keyzer, Frederik
    EUROPEAN RADIOLOGY, 2007, 17 (06) : 1385 - 1393